I.S. EN 61109:2008
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
INSULATORS FOR OVERHEAD LINES - COMPOSITE SUSPENSION AND TENSION INSULATORS FOR A.C. SYSTEMS WITH A NOMINAL VOLTAGE GREATER THAN 1 000 V - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
Hardcopy , PDF
28-02-2017
English
11-12-2008
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
FOREWORD
INTRODUCTION
1 Scope and object
2 Normative references
3 Terms, definitions and abbreviations
3.1 Terms and definitions
3.2 Abbreviations
4 Identification
5 Environmental conditions
6 Transport, storage and installation
7 Hybrid insulators
8 Tolerances
9 Classification of tests
9.1 Design tests
9.2 Type tests
9.3 Sample tests
9.4 Routine tests
10 Design tests
10.1 General
10.2 Test specimens for IEC 62217
10.2.1 Tests on interfaces and connections of end
fittings
10.2.2 Tracking and erosion test
10.2.3 Tests on core material
10.3 Product specific pre-stressing for IEC 62217
10.3.1 Sudden load release
10.3.2 Thermal-mechanical pre-stress
10.4 Assembled core load-time tests
10.4.1 Test specimens
10.4.2 Mechanical load test
11 Type tests
11.1 Electrical tests
11.2 Damage limit proof test and test of the
tightness of the interface between end
fittings and insulator housing
11.2.1 Test specimens
11.2.2 Performance of the test
11.2.3 Evaluation of the test
12 Sample tests
12.1 General rules
12.2 Verification of dimensions (E1 + E2)
12.3 Verification of the end fittings (E2)
12.4 Verification of tightness of the interface
between end fittings and insulator housing
(E2) and of the specified mechanical load,
SML (E1)
12.5 Galvanizing test (E2)
12.6 Re-testing procedure
13 Routine tests
13.1 Mechanical routine test
13.2 Visual examination
Annex A (informative) Principles of the damage limit,
load coordination and testing for composite
suspension and tension insulators
Annex B (informative) Example of two possible devices
for sudden release of load
Annex C (informative) Guidance on non-standard mechanical
stresses and dynamic mechanical loading of
composite tension/suspension insulators
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Bibliography
Applies to composite suspension/tension insulators consisting of a load-bearing cylindrical insulating solid core consisting of fibres - usually glass - in a resin based matrix, a housing (outside the insulating core) made of polymeric material and end fittings permanently attached to the insulating core.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
68
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
Standards | Relationship |
EN 61109:2008 | Identical |
IEC 61109:2008 | Identical |
IEC 60826:2017 | Design criteria of overhead transmission lines |
IEC 61466-1:2016 | Composite string insulator units for overhead lines with a nominal voltage greater than 1 000 V - Part 1: Standard strength and end fittings |
IEC 61467:2008 | Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests |
IEC 60050-471:2007 | International Electrotechnical Vocabulary (IEV) - Part 471: Insulators |
IEC 62217:2012 | Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria |
IEC 60383-1:1993 | Insulators for overhead lines with a nominal voltage above 1000 V - Part 1: Ceramic or glass insulator units for a.c. systems - Definitions, test methods and acceptance criteria |
EN 60383-1:1996/A11:1999 | INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1 KV - CERAMIC OR GLASS INSULATOR UNITS FOR A.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA |
EN 61466-1:2016 | Composite string insulator units for overhead lines with a nominal voltage greater than 1000 V - Part 1: Standard strength classes and end fittings |
IEC GUIDE 111:2004 | Electrical high-voltage equipment in high-voltage substations - Common recommendations for product standards |
EN 62217:2013 | Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria |
IEC 60383-2:1993 | Insulators for overhead lines with a nominal voltage above 1000 V - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria |
EN 60383-2:1995 | Insulators for overhead lines with a nominal voltage above 1 kV - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.