I.S. EN 60947-4-1:2010

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS (IEC 60947-4-1:2009 (EQV))

Available format(s)

Hardcopy , PDF

Superseded date

12-04-2019

Language(s)

English

Published date

01-01-2010

Preview

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

$310.11
Including GST where applicable

FOREWORD
INTRODUCTION (to amendment 1)
1 Scope and object
2 Normative references
3 Terms, definitions, symbols and abbreviations
4 Classification
5 Characteristics of contactors and starters
6 Product information
7 Normal service, mounting and transport conditions
8 Constructional and performance requirements
9 Tests
Annex A (normative) - Marking and identification of
        terminals of contactors and associated overload
        relays
Annex B (normative) - Special tests
Annex C Void
Annex D (informative) - Items subject to agreement
        between manufacturer and user
Annex E (Void)
Annex F (normative) - Requirements for auxiliary
        contact linked with power contact (mirror contact)
Annex G (informative) - Rated operational currents
        and rated operational powers of switching devices
        for electrical motors
Annex H (normative) - Extended functions to electronic
        overload relays
Annex I (informative) - AC1 contactors for use with
        semiconductor controlled motor loads
Annex J Void
Annex K (normative) - Procedure to determine data for
        electromechanical contactors used in functional
        safety applications
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications
Annex ZZ (informative) - Coverage of Essential
         Requirements of EC Directives

Applicable to the types of equipment listed in 1.1.1 and 1.1.2 whose main contacts are intended to be connected to circuits the rated voltage of which does not exceed 1000 V a.c. or 1500 V d.c.

DevelopmentNote
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
DocumentType
Standard
Pages
146
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy

IEC 61915-2:2011 Low-voltage switchgear and controlgear - Device profiles for networked industrial devices - Part 2: Root device profiles for starters and similar equipment
IEC 60381-1:1982 Analogue signals for process control systems. Part 1: Direct current signals
EN 60085:2008 Electrical insulation - Thermal evaluation and designation
EN 60034-1:2010/corrigendum Oct. 2010 ROTATING ELECTRICAL MACHINES - PART 1: RATING AND PERFORMANCE
IEC 61649:2008 Weibull analysis
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
EN 61439-1:2011 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
IEC 60269-2:2013+AMD1:2016 CSV Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61810-1:2015 Electromechanical elementary relays - Part 1: General and safety requirements
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV Low-voltage fuses - Part 1: General requirements
EN 61649:2008 Weibull analysis
EN 60947-1:2007/A2:2014 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014)
IEC 60072-1:1991 Dimensions and output series for rotating electrical machines - Part 1: Frame numbers 56 to 400 and flange numbers 55 to 1080
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
EN 60947-3:2009/A2:2015 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE-COMBINATION UNITS (IEC 60947-3:2008/A2:2015)
IEC 60410:1973 Sampling plans and procedures for inspection by attributes
IEC 60076-1:2011 Power transformers - Part 1: General
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV Low-voltage switchgear and controlgear - Part 1: General rules
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
EN 62061:2005/A2:2015 SAFETY OF MACHINERY - FUNCTIONAL SAFETY OF SAFETY-RELATED ELECTRICAL, ELECTRONIC AND PROGRAMMABLE ELECTRONIC CONTROL SYSTEMS (IEC 62061:2005/A2:2015)
IEC 61051-2:1991 Varistors for use in electronic equipment - Part 2: Sectional specification for surge suppression varistors
IEC 60034-1:2017 Rotating electrical machines - Part 1: Rating and performance
IEC 61095:2009 Electromechanical contactors for household and similar purposes
IEC 61513:2011 Nuclear power plants - Instrumentation and control important to safety - General requirements for systems
EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
IEC 60947-3:2008+AMD1:2012+AMD2:2015 CSV Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units
IEC 61439-1:2011 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
IEC 60947-2:2016 Low-voltage switchgear and controlgear - Part 2: Circuit-breakers
IEC 62061:2005+AMD1:2012+AMD2:2015 CSV Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems
EN 60947-2:2017 Low-voltage switchgear and controlgear - Part 2: Circuit-breakers
ISO 13849-1:2015 Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 60300-3-5:2001 Dependability management - Part 3-5: Application guide - Reliability test conditions and statistical test principles

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more