I.S. EN 60938-1:1999
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
FIXED INDUCTORS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION - PART 1: GENERIC SPECIFICATION
Hardcopy , PDF
07-09-2021
English
01-01-1999
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
FOREWORD
1 General
1.1 Scope
1.2 Normative references
2 Technical data
2.1 Units and symbols
2.2 Definitions
2.3 Preferred values
2.4 Marking
3 Quality assessment procedures
3.1 General
3.2 Primary stage of manufacture
3.3 Structurally similar inductors
3.4 Qualification approval procedures
3.5 Quality conformance inspection
3.6 Alternative test methods
3.7 Unchecked parameters
4 Test and measurement procedure
4.1 General
4.2 Standard atmospheric conditions
4.3 Drying
4.4 Visual examination and check of dimensions
4.5 Insulation resistance
4.6 Voltage proof
4.7 Inductance
4.8 Insertion loss
4.9 Robustness of terminations
4.10 Resistance to soldering heat
4.11 Solderability (applicable only for
terminations intended to be soldered)
4.12 Rapid change of temperature
4.13 Vibration
4.14 Bump
4.15 Shock
4.16 Container sealing
4.17 Climatic sequence
4.18 Damp heat, steady state
4.19 Temperature rise
4.20 Endurance
4.21 Passive flammability
4.22 Active flammability
4.23 Solvent resistance of marking
4.24 Component solvent resistance
Annex A (normative) Interpretation of sampling plans and
procedures as described in IEC 60410 for use
within the IEC quality assessment system for
electronic components (IECQ)
Annex B (normative) Rules for the preparation of detail
specifications for capacitors and resistors for
electronic equipment
Annex C (normative) Requirements for earth inductors
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Applicable to inductors intended for electromagnetic interference suppression meant to be used in or in association with, electronic or electrical equipment and machines. Restricted to inductors where safety tests are appropriate. Also includes two or more inductors within one enclosure.
DevelopmentNote |
Supersedes I.S. EN 138000. (03/2007) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
52
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
SN EN 60938-1 : 1999 | Identical |
IEC 60938-1:1999+AMD1:2006 CSV | Identical |
EN 60938-1:1999/A1:2007 | Identical |
BS EN 60938-1:2000 | Identical |
DIN EN 60938-1 : 2008 | Identical |
NBN EN 60938-1 : 2000 AMD 1 2007 | Identical |
NF EN 60938-1 : 2008 AMD 1 2008 | Identical |
HD 323.2.20 : 200S3 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST T - SOLDERING |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IECQ 001002-3:2005 | IEC QUALITY ASSESSMENT SYSTEM FOR ELECTRONIC COMPONENTS (IECQ) - RULES OF PROCEDURE - PART 3: APPROVAL PROCEDURES |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60068-2-13:1983 | Basic environmental testing procedures - Part 2-13: Tests - Test M: Low air pressure |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
HD 323.2.3 : 200S2 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST CA - DAMP HEAT, STEADY STATE |
IEC 60068-2-3:1969 | Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state |
IEC 60294:2012 | Measurement of the dimensions of a cylindrical component with axial terminations |
EN 60068-2-17:1994 | Environmental testing - Part 2: Tests - Test Q: Sealing |
IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
EN 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60062:2016 | Marking codes for resistors and capacitors |
EN 60062:2016/AC:2016-12 | MARKING CODES FOR RESISTORS AND CAPACITORS (IEC 60062:2016/COR1:2016) |
EN 60068-2-29:1993 | Environmental testing - Part 2: Tests - Test Eb and guidance: Bump |
EN 60068-2-13:1999 | Environmental testing - Part 2: Tests - Test M: Low air pressure |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
CISPR 17:2011 | Methods of measurement of the suppression characteristics of passive EMC filtering devices |
IEC 60068-2-29:1987 | Environmental testing. Part 2: Tests. Test Eb and guidance: Bump |
EN 60335-1:2012/A13:2017 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED) |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 60068-2-45:1992/A1:1993 | Environmental testing - Part 2: Tests - Test Xa and guidance: Immersion in cleaning solvents |
EN 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 60695-2-2:1994/A1:1995 | FIRE HAZARD TESTING - TEST METHODS - NEEDLE-FLAME TEST |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.