I.S. EN 60079-14:2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION
Hardcopy , PDF
16-07-2020
English
01-01-2014
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
National Foreword
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Selection of equipment
6 Protection from dangerous (incendive) sparking
7 Electrical protection
8 Switch-off and electrical isolation
9 Cables and wiring systems
10 Cable entry systems and blanking elements
11 Rotating electrical machines
12 Luminaires
13 Electric heating systems
14 Additional requirements for type of protection
'd' - Flameproof enclosures
15 Additional requirements for type of protection
'e' - Increased safety
16 Additional requirements for types of protection
'i' - Intrinsic safety
17 Additional requirements for pressurized enclosures
18 Additional requirements for type of protection 'n'
19 Additional requirements for type of protection
'o'- Oil immersion
20 Additional requirements for type of protection
'q' - Powder filling
21 Additional requirements for type of protection
'm' - Encapsulation
22 Additional requirements for type of protection
'op' - Optical radiation
23 Additional requirements for type of protection
't' - Protection by enclosure
Annex A (normative) - Knowledge, skills and competencies
of responsible persons, operatives/technicians
and designers
Annex B (informative) - Safe work procedure guidelines for
explosive gas atmospheres
Annex C (normative) - Initial inspection - Equipment-specific
inspection schedules
Annex D (informative) - Electrical installations in extremely
low ambient temperature
Annex E (informative) - Restricted breathing test for cables
Annex F (informative) - Installation of electrical trace
heating systems
Annex G (normative) - Potential stator winding discharge
risk assessment - Ignition risk factors
Annex H (normative) - Verification of intrinsically safe
circuits with more than one associated apparatus
with linear current/voltage characteristics
Annex I (informative) - Methods of determining the
maximum system voltages and currents in
intrinsically safe circuits with more
than one associated apparatus with
linear current/voltage characteristics
(as required by Annex H)
Annex J (informative) - Determination of cable parameters
Annex K (normative) - Additional requirements for type
of protection 'op' - Optical radiation
Annex L (informative) - Examples of dust layers of excessive
thickness
Annex M (informative) - Hybrid mixtures
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Includes the specific requirements for the design, selection, erection and initial inspection of electrical installations in, or associated with, explosive atmospheres.
DevelopmentNote |
Supersedes I.S. EN 61241-14. (11/2011) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
298
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NBN EN 60079-14 : 2014 COR 2016 | Identical |
UNE-EN 60079-14:2016 | Identical |
EN 60079-14:2014/AC:2016 | Identical |
BS EN 60079-14:2014 | Identical |
SN EN 60079-14:2014 | Identical |
NF EN 60079-14 : 2014 | Identical |
I.S. 821:2006 | GAS PRESSURE REGULATING STATIONS FOR DISTRIBUTION |
IEC 60243-1:2013 | Electric strength of insulating materials - Test methods - Part 1: Tests at power frequencies |
IEC 60079-1:2014 RLV | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
EN 60079-26:2015 | Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga |
IEC 61024-1:1990 | Protection of structures against lightning - Part 1: General principles |
EN 60079-29-4:2010 | Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases |
EN 60079-1:2014 | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
EN 60079-10-1:2015 | Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres |
IEC 60079-30-2:2007 | Explosive atmospheres - Part 30-2: Electrical resistance trace heating - Application guide for design, installation and maintenance |
EN 60079-29-1:2016 | Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases |
EN 60034-1:2010/corrigendum Oct. 2010 | ROTATING ELECTRICAL MACHINES - PART 1: RATING AND PERFORMANCE |
IEC 60079-19:2010+AMD1:2015 CSV | Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
EN 60079-0:2012/A11:2013 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
ISO 10807:1994 | Pipework — Corrugated flexible metallic hose assemblies for the protection of electrical cables in explosive atmospheres |
IEC 60079-17:2013 | Explosive atmospheres - Part 17: Electrical installations inspection and maintenance |
EN 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
EN 60079-19:2011/A1:2015 | EXPLOSIVE ATMOSPHERES - PART 19: EQUIPMENT REPAIR, OVERHAUL AND RECLAMATION (IEC 60079-19:2010) |
EN 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules |
HD 60364-4-41:2017/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
IEC 60079-18:2014 RLV | Explosive atmospheres - Part 18: Equipment protection by encapsulation “m” |
IEC 60332-2-2:2004 | Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame |
EN 60079-10-2:2015 | Explosive atmospheres - Part 10-2: Classification of areas - Explosive dust atmospheres |
IEC 60079-10-1:2015 | Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres |
IEC 60079-29-4:2009 | Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases |
IEC 61241-11:2005 | Electrical apparatus for use in the presence of combustible dust - Part 11: Protection by intrinsic safety 'iD' |
EN 60079-6:2015 | Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o" |
IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
EN 60332-1-2:2004/A11:2016 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015) |
EN 60079-28:2015 | Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation |
IEC TR 60079-16:1990 | Electrical apparatus for explosive gas atmospheres. Part 16: Artificial ventilation for the protection of analyser(s) houses |
IEC 60614-2-5:1992 | Specifications for conduits for electrical installations - Part 2: Particular specifications for conduits - Section 5: Flexible conduits |
IEC 60079-5:2015 RLV | Explosive atmospheres - Part 5: Equipment protection by powder filling "q" |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
EN 60079-30-1:2017 | Explosive atmospheres - Part 30-1: Electrical resistance trace heating - General and testing requirements |
EN 60079-11:2012 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
EN 62305-3:2011 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
IEC TS 60034-25:2014 | Rotating electrical machines - Part 25: AC electrical machines used in power drive systems - Application guide |
IEC 61241-1:2004 | Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD" |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC TS 60034-17:2006 | Rotating electrical machines - Part 17: Cage induction motors when fed from converters - Application guide |
IEC 60755:2017 | General safety requirements for residual current operated protective devices |
IEC 60079-29-2:2015 RLV | Explosive atmospheres - Part 29-2: Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen |
EN 50272-2:2001 | Safety requirements for secondary batteries and battery installations - Part 2: Stationary batteries |
IEC 60079-6:2015 | Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o" |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 60034-1:2017 | Rotating electrical machines - Part 1: Rating and performance |
EN 60243-1:2013 | ELECTRIC STRENGTH OF INSULATING MATERIALS - TEST METHODS - PART 1: TESTS AT POWER FREQUENCIES (IEC 60243-1:2013) |
IEC 61241-4:2001 | Electrical apparatus for use in the presence of combustible dust - Part 4: Type of protection "pD" |
IEC 60079-31:2013 | Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t" |
IEC 60079-30-1:2007 | Explosive atmospheres - Part 30-1: Electrical resistance trace heating - General and testing requirements |
EN 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
IEC 61285:2015 | Industrial-process control - Safety of analyser houses |
IEC 61439-1:2011 | Low-voltage switchgear and controlgear assemblies - Part 1: General rules |
EN 60079-17:2014 | Explosive atmospheres - Part 17: Electrical installations inspection and maintenance |
IEC 61241-2-1:1994 | Electrical apparatus for use in the presence of combustible dust - Part 2: Test methods - Section 1: Methods for determining the minimum ignition temperatures of dust |
CLC/TR 50427:2004 | Assessment of inadvertent ignition of flammable atmospheres by radio-frequency radiation - Guide |
EN 61010-1:2010 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 61010-1:2010+AMD1:2016 CSV | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
IEC 62305-3:2010 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
EN 60079-13:2017 | Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" |
IEC 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
IEC 60079-13:2017 | Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" |
EN 61285:2015 | Industrial-process control - Safety of analyzer houses |
IEC 60079-26:2014 RLV | Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga |
CLC/TR 50404:2003 | Electrostatics - Code of practice for the avoidance of hazards due to static electricity |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.