I.S. EN 50600-2-5:2016
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS
Hardcopy , PDF
08-05-2021
English
01-01-2016
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
National Foreword
European foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Conformance
5 Physical security
6 Protection Class against unauthorized access
7 Protection Class against fire events igniting within
data centre spaces
8 Protection Class against environmental events
(other than fire) within data centre spaces
9 Protection Class against environmental events
outside the data centre spaces
10 Systems to prevent unauthorized access
Annex A (informative) - Pressure relief: Additional
information
Bibliography
Specifies the physical security of data centres based upon the criteria and classifications for 'availability', 'security' and 'energy efficiency enablement' within EN 50600-1.
DocumentType |
Standard
|
Pages |
44
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
EN 50600-2-5:2016 | Identical |
IEC 60839-11-31:2016 | Alarm and electronic security systems - Part 11-31: Electronic access control systems - Core interoperability protocol based on Web services |
EN 50600-3-1:2016 | Information technology - Data centre facilities and infrastructures - Part 3-1: Management and operational information |
CEN/TS 14972:2011 | Fixed firefighting systems - Watermist systems - Design and installation |
EN 50600-2-1:2014 | Information technology - Data centre facilities and infrastructures - Part 2-1: Building construction |
ISO 6183:2009 | Fire protection equipment Carbon dioxide extinguishing systems for use on premises Design and installation |
EN 62676-1-1:2014/AC:2014 | VIDEO SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 1-1: SYSTEM REQUIREMENTS - GENERAL (IEC 62676-1-1:2013) |
EN 1627:2011 | Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Requirements and classification |
EN 60839-11-1:2013/AC:2015 | ALARM AND ELECTRONIC SECURITY SYSTEMS - PART 11-1: ELECTRONIC ACCESS CONTROL SYSTEMS - SYSTEM AND COMPONENTS REQUIREMENTS (IEC 60839-11-1:2013) |
PREN 16750 : DRAFT 2014 | FIXED FIREFIGHTING SYSTEMS - OXYGEN REDUCTION SYSTEMS - DESIGN, INSTALLATION, PLANNING AND MAINTENANCE |
EN 50600-2-3:2014 | Information technology - Data centre facilities and infrastructures - Part 2-3: Environmental control |
IEC 60839-11-1:2013 | Alarm and electronic security systems - Part 11-1: Electronic access control systems - System and components requirements |
CEN/TS 54-14:2004 | Fire detection and fire alarm systems - Part 14: Guidelines for planning, design, installation, commissioning, use and maintenance |
IEC 60839-11-32:2016 | Alarm and electronic security systems - Part 11-32: Electronic access control systems - Access control monitoring based on Web services |
EN 50600-1:2012 | INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 1: GENERAL CONCEPTS |
EN 1366-3:2009 | Fire resistance tests for service installations - Part 3: Penetration seals |
CLC/TS 50398:2009 | Alarm systems - Combined and integrated alarm systems - General requirements |
CEN/TS 14816:2008 | Fixed firefighting systems - Water spray systems - Design, installation and maintenance |
EN 60839-11-1:2013/AC:2015 | ALARM AND ELECTRONIC SECURITY SYSTEMS - PART 11-1: ELECTRONIC ACCESS CONTROL SYSTEMS - SYSTEM AND COMPONENTS REQUIREMENTS (IEC 60839-11-1:2013) |
IEC 60839-11-2:2014 | Alarm and electronic security systems - Part 11-2: Electronic access control systems - Application guidelines |
EN 50600-2-4:2015 | Information technology - Data centre facilities and infrastructures - Part 2-4: Telecommunications cabling infrastructure |
ISO 7240-14:2013 | Fire detection and alarm systems — Part 14: Design, installation, commissioning and service of fire detection and fire alarm systems in and around buildings |
EN 60839-11-2:2015/AC:2015 | ALARM AND ELECTRONIC SECURITY SYSTEMS - PART 11-2: ELECTRONIC ACCESS CONTROL SYSTEMS - APPLICATION GUIDELINES (IEC 60839-11-2:2014) |
EN 1047-2:2009+A1:2013 | Secure storage units - Classification and methods of test for resistance to fire - Part 2: Data rooms and data container |
EN 54-13:2017 | Fire detection and fire alarm systems - Part 13: Compatibility and connectability assessment of system components |
EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |
IEC 62676-1-1:2013 | Video surveillance systems for use in security applications - Part 1-1: System requirements - General |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.