I.S. EN 50516-1-1:2011
Current
The latest, up-to-date edition.
INDUSTRIAL CONNECTOR SETS AND INTERCONNECT COMPONENTS TO BE USED IN OPTICAL FIBRE CONTROL AND COMMUNICATION SYSTEMS - PRODUCT SPECIFICATIONS - PART 1-1: TYPE SC-RJ PC INDUSTRIAL TERMINATED ON EN 60793-2-10 CATEGORY A1A AND A1B MULTIMODE FIBRE TO MEET THE REQUIREMENTS OF CATEGORY I (INDUSTRIAL ENVIRONMENTS) AS SPECIFIED IN IEC 61753-1-3
Hardcopy , PDF
English
01-01-2011
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Foreword
Introduction
1 Scope
2 Normative references
3 Description
4 Variants
5 Dimensional requirements
6 Tests
7 Test report
8 Product qualification requirements
Annex A (informative) - Attenuation against reference
Annex B (normative) - Sample size and product sourcing
requirements
Annex C (informative) - Details of environmental classification
out of EN 50173-1 (MICE)
Annex D (informative) - Details of sample construction
Annex E (normative) - Test setup - Bending moment test
Annex F (informative) - Patent statement concerning SC-RJ
industrial connectors
Bibliography
Includes the initial, start of life dimensional, optical, mechanical and environmental performance requirements that an SC-RJ connector set with one side protected by an industrial housing with the fibres terminated with cylindrical zirconia PC ferrules, an adaptor fitted with resilient alignment sleeves and patchcord shall meet in order for it to be categorised as an EN standard product.
DocumentType |
Standard
|
Pages |
43
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
EN 50516-1-1:2011/AC:2012 | Identical |
IEC 61300-3-10:2006 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-10: Examinations and measurements - Gauge retention force |
IEC 61300-2-35:2014 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-35: Tests - Cable nutation |
IEC 60794-3:2014 | Optical fibre cables - Part 3: Outdoor cables - Sectional specification |
ISO 8015:2011 | Geometrical product specifications (GPS) Fundamentals Concepts, principles and rules |
EN 61300-2-5:2011 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion |
EN 61300-3-38 : 2012 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 3-38: EXAMINATIONS AND MEASUREMENTS - GROUP DELAY, CHROMATIC DISPERSION AND PHASE RIPPLE |
EN ISO 8015:2011 | Geometrical product specifications (GPS) - Fundamentals - Concepts, principles and rules (ISO 8015:2011) |
EN 61300-2-18:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests - Dry heat - High temperature endurance |
EN 61755-2-1:2006 | Fibre optic connector optical interfaces - Part 2-1: Optical interface standard single mode non-angled physically contacting fibres |
IEC 61300-3-28:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-28: Examinations and measurements - Transient loss |
EN 61300-2-10:2012 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 2-10: TESTS - CRUSH RESISTANCE (IEC 61300-2-10:2012) |
EN 61300-3-4:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation |
IEC 61300-3-16:2003 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-16: Examinations and measurements - Endface radius of spherically polished ferrules |
EN 61300-2-17:2011 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-17: Tests - Cold |
EN 61076-3-106 : 2006 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-106: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE |
EN 60793-2-50:2016 | Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres |
EN 61300-2-2:2009/corrigendum:2009 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 2-2: TESTS - MATING DURABILITY |
IEC 61300-2-12:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-12: Tests - Impact |
EN 61300-2-6:2011 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-6: Tests - Tensile strength of coupling mechanism |
IEC 61300-2-9:2017 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-9: Tests - Shock |
IEC 61755-2-1:2006 | Fibre optic connector optical interfaces - Part 2-1: Optical interface standard single mode non-angled physically contacting fibres |
EN 60794-3:2015 | Optical fibre cables - Part 3: Sectional specification - Outdoor cables |
EN 61300-2-35:2014 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-35: Tests - Cable nutation |
EN 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
IEC 61300-2-17:2010 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-17: Tests - Cold |
IEC 61753-1:2007 | Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards |
EN 61753-1:2007 | Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards |
EN 61300-3-23:1998 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-23: Examination and measurements - Fibre position relative to ferrule endface |
IEC 61300-2-46:2006 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-46: Tests - Damp heat, cyclic |
IEC 61300-2-5:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion |
IEC 61300-3-34:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-34: Examinations and measurements - Attenuation of random mated connectors |
IEC 61300-3-23:1998 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-23: Examination and measurements - Fibre position relative to ferrule endface |
IEC 61754-24-21:2009 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 24-21: Type SC-RJ connectors with protective housings based on IEC 61076-3-106, variant 06 |
IEC 61300-2-26:2006 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-26: Tests - Salt mist |
EN 50173-3 : 2007 COR 2011 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 3: INDUSTRIAL PREMISES |
IEC 60874-19-1:2007 | Fibre optic interconnecting devices and passive components - Connectors for optical fibres and cables - Part 19-1: Fibre optic patch cord connector type SC-PC (floating duplex) standard terminated on multimode fibre type A1a, A1b - Detail specification |
EN 61300-3-16:2003 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-16: Examinations and measurements - Endface radius of spherically polished ferrules |
EN 50173-1:2011 | Information technology - Generic cabling systems - Part 1: General requirements |
EN 61754-4:2013/AC:2014 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - FIBRE OPTIC CONNECTOR INTERFACES - PART 4: TYPE SC CONNECTOR FAMILY (IEC 61754-4:2013) |
EN 61300-2-34:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-34: Tests - Resistance to solvents and contaminating fluids of interconnecting components and closures |
IEC 61300-2-18:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests - Dry heat - High temperature endurance |
EN 50174-2 : 2009 AMD 2 2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS |
IEC 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
EN 60794-2-50 : 2008 | OPTICAL FIBRE CABLES - PART 2-50: INDOOR CABLES - FAMILY SPECIFICATION FOR SIMPLEX AND DUPLEX CABLES FOR USE IN TERMINATED CABLE ASSEMBLIES |
EN 61300-3-1:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination |
IEC 61300-3-6:2008 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss |
IEC 61300-3-15:2006 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-15: Examinations and measurements - Dome eccentricity of a convex polished ferrule endface |
IEC 61076-3-106:2006 | Connectors for electronic equipment - Product requirements - Part 3-106: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for industrial environments incorporating the IEC 60603-7 series interface |
EN 61300-3-6:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss |
IEC 61300-3-35:2015 RLV | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-35: Examinations and measurements - Visual inspection of fibre optic connectors and fibre-stub transceivers |
EN 61280-1-4:2010 | Fibre optic communication subsystem test procedures - Part 1-4: General communication subsystems - Light source encircled flux measurement method |
IEC 61300-2-7:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-7: Tests - Bending moment |
EN 61300-2-12:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-12: Tests - Impact |
IEC 61300-3-4:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation |
IEC 61300-2-34:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-34: Tests - Resistance to solvents and contaminating fluids of interconnecting components and closures |
EN 61755-3-1:2009 | Fibre optic connector optical interfaces - Part 3-1: Optical interface, 2,5 mm and 1,25 mm diameter cylindrical full zirconia PC ferrule, single mode fibre |
EN 61300-2-4:1997 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
EN 61300-3-15:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-15: Examinations and measurements - Dome eccentricity of a convex polished ferrule endface |
EN 61755-1:2006/corrigendum:2006 | FIBRE OPTIC CONNECTOR OPTICAL INTERFACES - PART 1: OPTICAL INTERFACES FOR SINGLE MODE NON-DISPERSION SHIFTED FIBRES - GENERAL AND GUIDANCE |
IEC 61300-3-38:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-38: Examinations and measurements - Group delay, chromatic dispersion and phase ripple |
EN 61754-24-21 : 2009 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - FIBRE OPTIC CONNECTOR INTERFACES - PART 24-21: TYPE SC-RJ CONNECTORS WITH PROTECTIVE HOUSINGS BASED ON IEC 61076-3-106, VARIANT 06 |
EN 61300-3-35:2015 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-35: Examinations and measurements - Visual inspection of fibre optic connectors and fibre-stub transceivers |
EN 61300-3-28:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-28: Examinations and measurements - Transient loss |
IEC 60793-2-50:2015 | Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres |
EN 61300-3-42:2008 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-42: Examinations and measurements - Attenuation of single mode alignment sleeves and or adaptors with resilient alignment sleeves |
IEC 61754-24:2009 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 24: Type SC-RJ connector family |
IEC 61753-1-3:2014 | Fibre optic interconnecting devices and passive components - Performance standard - Part 1-3: General and guidance for single-mode fibre optic connector and cable assembly for industrial environment, Category I |
IEC 61300-2-2:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-2: Tests - Mating durability |
IEC 61300-2-4:1995 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
TS 100 671 : 1.3.1 | TRANSMISSION AND MULTIPLEXING (TM); PASSIVE OPTICAL COMPONENTS; OPTICAL FIBRE CONNECTORS FOR SINGLE MODE OPTICAL FIBRE COMMUNICATION SYSTEMS; COMMON REQUIREMENTS AND CONFORMANCE TESTING |
IEC 61754-4:2013 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 4: Type SC connector family |
IEC 61300-2-6:2010 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-6: Tests - Tensile strength of coupling mechanism |
EN 61300-3-34:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-34: Examinations and measurements - Attenuation of random mated connectors |
EN 61300-2-26:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-26: Tests - Salt mist |
IEC 60794-2-50:2008 | Optical fibre cables - Part 2-50: Indoor cables - Family specification for simplex and duplex cables for use in terminated cable assemblies |
EN 61300-2-7:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-7: Tests - Bending moment |
IEC 61755-1:2005 | Fibre optic connector optical interfaces - Part 1: Optical interfaces for single mode non-dispersion shifted fibres - General and guidance |
IEC 61300-3-1:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination |
IEC 61755-3-1:2006 | Fibre optic connector optical interfaces - Part 3-1: Optical interface, 2,5 mm and 1,25 mm diameter cylindrical full zirconia PC ferrule, single mode fibre |
EN 61300-3-10:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-10: Examinations and measurements - Gauge retention force |
IEC 61300-2-10:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-10: Tests - Crush resistance |
IEC 61300-3-42:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-42: Examinations and measurements - Attenuation of single mode alignment sleeves and or adaptors with resilient alignment sleeves |
IEC 61280-1-4:2009 | Fibre optic communication subsystem test procedures - Part 1-4: General communication subsystems - Light source encircled flux measurement method |
EN 61754-24:2010 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 24: Type SC-RJ connector family |
EN 61300-2-9:2017 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-9: Tests - Shock |
EN 61300-2-46:2006 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-46: Tests - Damp heat cyclic |
IEC 61300-2-27:1995 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-27: Tests - Dust - Laminar flow |
EN 61300-2-27:1997 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-27: Tests - Dust - Laminar flow |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.