I.S. EN 50329:2007
Current
The latest, up-to-date edition.
RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS
Hardcopy , PDF
English
01-01-2007
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Introduction
1 General
2 General requirements for a traction transformer
3 Directly-coupled traction transformer
4 Traction converter transformers
5 Auxiliary transformers
6 Traction auto-transformers
Annex A (informative) - Preferred duty classes
Annex B (normative) - Insulation characteristics and test
values
Annex C (normative) - Determination of losses and of
equivalent current by means of alternative methods
Annex E (informative) - Evaluation of traction transformer
behaviour
Annex F (informative) - Information for tenders and orders
Bibliography
Specifies specific characteristics of traction transformers, used in traction substation or along the track for the supply of power to a.c. and d.c. traction systems or to provide power to auxiliary services.
DevelopmentNote |
Supersedes I.S. HD 591. (07/2005) 2003 Edition Re-Issued in June 2010 & incorporates AMD 1 2010. (06/2010) Partially Supersedes 1993 edition of I.S. EN 60146-1-3. (07/2017)
|
DocumentType |
Standard
|
Pages |
37
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Supersedes |
Standards | Relationship |
SN EN 50329 : 2003 | Identical |
NF EN 50329 : 2005 AMD 1 2011 | Identical |
DIN EN 50329 : 2011 COR 1 2011 | Identical |
BS EN 50329 : 2003 | Identical |
NEN EN 50329 : 2003 AMD 1 2010 | Identical |
EN 50329:2003/A1:2010 | Identical |
UNE-EN 50329:2004 | Identical |
HD 428.4 : 200S1 | THREE-PHASE OIL-IMMERSED DISTRIBUTION TRANSFORMERS 50 HZ, FROM 50 TO 2500 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - DETERMINATION OF THE POWER RATING OF A TRANSFORMER LOADED WITH NON-SINUSODIAL CURRENTS |
IEC 60076-7:2005 | Power transformers - Part 7: Loading guide for oil-immersed power transformers |
R009-002 : 1998 | RAILWAY APPLICATIONS - GUIDE FOR THE USE OF THE TERMINOLOGY FOR TESTING PROCEDURES |
EN 50122-1:2011/A4:2017 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 1: PROTECTIVE PROVISIONS AGAINST ELECTRIC SHOCK |
EN 61000-2-12:2003 | Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems |
EN 60076-5:2006 | Power transformers - Part 5: Ability to withstand short-circuit |
EN 60076-11:2004 | Power transformers - Part 11: Dry-type transformers |
IEC 60076-5:2006 | Power transformers - Part 5: Ability to withstand short circuit |
HD 538.3 : 200S1 | THREE-PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 2500 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 3: DETERMINATION OF THE POWER RATING OF A TRANSFORMER LOADED WITH NON-SINUSOIDAL CURRENT |
EN 50124-1:2017 | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment |
EN 50125-2:2002/corrigendum:2010 | RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 2: FIXED ELECTRICAL INSTALLATIONS |
IEC 60076-3:2013 | Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air |
EN 50327 : 2003 AMD 1 2005 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS |
IEC 60076-1:2011 | Power transformers - Part 1: General |
EN 50152-1 : 2012 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV |
EN 60076-1:2011 | POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011) |
EN 50163 : 2004 COR 2013 | RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS |
IEC 60905:1987 | Loading guide for dry-type power transformers |
EN 50121-5:2017 | Railway applications - Electromagnetic compatibility - Part 5: Emission and immunity of fixed power supply installations and apparatus |
IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
EN 61378-1:2011 | Convertor transformers - Part 1: Transformers for industrial applications |
EN 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
EN 50328 : 2003 COR 2006 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRONIC POWER CONVERTERS FOR SUBSTATIONS |
IEC 61378-1:2011 | Converter transformers - Part 1: Transformers for industrial applications |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.