I.S. EN 50164-1:2008
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
LIGHTNING PROTECTION COMPONENTS (LPC) - PART 1: REQUIREMENTS FOR CONNECTION COMPONENTS
Hardcopy , PDF
07-06-2012
English
01-01-2008
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
1 Scope
2 Normative references
3 Definitions
4 Classification
4.1 According to its capability to withstand lightning current
4.2 According to its installation
5 Requirements
5.1 General
5.2 Installation instructions
5.3 Lightning current carrying capability
5.4 Screwed clamping connection
5.5 Dismantling of test joints
5.6 Damage to conductors and metal installations
5.7 Safe connection
5.8 Marking
5.9 Terminals of bonding bars
6 Tests
6.1 General conditions for tests
6.2 Test preparation
6.3 Electrical test
6.4 Marking test
7 Electromagnetic compatibility (EMC)
8 Structure and content of the test report
8.1 Report identification
8.2 Specimen description
8.3 Conductor
8.4 Standards and references
8.5 Test procedure
8.6 Testing equipment description
8.7 Measuring instruments description
8.8 Results and parameters recorded
8.9 Statement of pass/fail
Annex A (informative) Typical arrangements for various LPC's
Annex B (normative) Conditioning/ageing for connection components
Annex C (informative) Rationale to reduce the number of tests
Describes the requirements and tests for metallic connection components that form part of a Lightning Protection System (LPS). Typically these can be connectors, bonding and bridging components, expansion pieces and test joints.
DocumentType |
Standard
|
Pages |
18
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
UNE-EN 50164-1:2009 | Identical |
NBN EN 50164-1 : 2010 | Identical |
NEN EN 50164-1 : 2008 | Identical |
EN 50164-1:2008 | Identical |
DIN EN 50164-1 : 2009 | Identical |
SN EN 50164-1 : 2008 | Identical |
BS EN 50164-1:2008 | Identical |
NF EN 50164-1 : 2008 | Identical |
EN 62305-4:2011/AC:2016 | PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES (IEC 62305-4:2010) |
EN 62305-4:2011/AC:2016-11 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
IEC 62305-1:2010 | Protection against lightning - Part 1: General principles |
EN ISO 6988:1994 | Metallic and other non-organic coatings - Sulfur dioxide test with general condensation of moisture (ISO 6988:1985) |
EN 62305-3:2011 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
IEC 62305-4:2010 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
ISO 6988:1985 | Metallic and other non organic coatings Sulfur dioxide test with general condensation of moisture |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
IEC 62305-3:2010 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
ISO 6957:1988 | Copper alloys Ammonia test for stress corrosion resistance |