I.S. EN 50117-2-1:2005
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
COAXIAL CABLES - PART 2-1: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
Hardcopy , PDF
29-03-2022
English
01-01-2005
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
1 Scope
2 Normative references
3 Definitions
4 Requirements for cable construction
5 Tests for completed cables
6 Cable types
Pertains to indoor drop cables for use in cabled distribution systems operating at temperature between -40 Degree C and +70 Degree C and at frequencies between 5 MHz and 1000 MHz and complying with the requirements of EN 50083.
DevelopmentNote |
To be read in conjunction with I.S. EN 50117-1. (09/2002) Supersedes I.S. EN 50117-2. (01/2003)
|
DocumentType |
Standard
|
Pages |
22
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
Supersedes |
Standards | Relationship |
DIN EN 50117-2-1 : 2014 | Identical |
NF EN 50117-2-1 : 2005 AMD 2 2016 | Identical |
BS EN 50117-2-1 : 2005 | Identical |
SN EN 50117-2-1:2005+A1:2008+A2:2013 | Identical |
EN 50117-2-1:2005/A2:2013 | Identical |
NEN EN 50117-2-1 : 2005 AMD 2 2013 | Identical |
UNE-EN 50117-2-1:2008 | Identical |
EN 62153-1-1:2004 | Metallic communication cables test methods - Part 1-1: Electrical - Measurement of the pulse/step return loss in the frequency domain using the Inverse Discrete Fourier Transformation (IDFT) |
EN 50290-2-27 : 2002 COR 2010 | COMMUNICATION CABLES - PART 2-27: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT THERMOPLASTIC SHEATHING COMPOUNDS |
EN 50290-2-23:2013 | COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI-PAIR CABLES USED IN ACCESS TELECOMMUNICATION NETWORKS: OUTDOOR CABLES |
EN 50290-4-1:2014 | Communication cables - Part 4-1: General considerations for the use of cables - Environmental conditions and safety aspects |
IEC 62153-1-1:2003 | Metallic communication cables test methods - Part 1-1: Electrical - Measurement of the pulse/step return loss in the frequency domain using the Inverse Discrete Fourier Transformation (IDFT) |
EN 50290-1-2:2004 | Communication cables - Part 1-2: Definitions |
EN 50290-2-25:2013 | COMMUNICATION CABLES - PART 2-25: COMMON DESIGN RULES AND CONSTRUCTION - POLYPROPYLENE INSULATION COMPOUNDS |
IEC 61196-1-115:2006 | Coaxial communication cables - Part 1-115: Electrical test methods - Test for regularity of impedance (pulse/step function return loss) |
EN 50117-1 : 2002 AMD 2 2013 | COAXIAL CABLES - PART 1: GENERIC SPECIFICATION |
EN 50290-2-24 : 2002 AMD 1 2008 | COMMUNICATION CABLES - PART 2-24: COMMON DESIGN RULES AND CONSTRUCTION - PE SHEATHING |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.