I.S. EN 16846-1:2017
Current
The latest, up-to-date edition.
PHOTOCATALYSIS - MEASUREMENT OF EFFICIENCY OF PHOTOCATALYTIC DEVICES USED FOR THE ELIMINATION OF VOC AND ODOUR IN INDOOR AIR IN ACTIVE MODE - PART 1: BATCH MODE TEST METHOD WITH A CLOSED CHAMBER
Hardcopy , PDF
English
01-01-2017
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
National Foreword
European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Principle
6 Apparatus
7 Test performance
8 Test report
Annex A (informative) - Schematic diagram of an
air tight chamber
Annex B (informative) - Types of sorbent apparatus
for thermal desorption cartridges
Annex C (informative) - Examples of a chamber
blanks analysis
Annex D (informative) - Analysis of the reaction
mixture
Annex E (informative) - Example of a plot of
temperature and relative humidity,
as well as developments in pollutants
and CO[2]
Annex F (informative) - Example of test at low
concentration with formaldehyde
Annex G (informative) - CADR calculation
Annex H (informative) - Calculation of CADR
Explains the methodologies to be used in a laboratory air tight chamber to test prototype or commercial air cleaner systems with a maximum flow rate of 1,000 m[3]/h used for photocatalytic indoor air remediation.
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
EN 16846-1:2017 | Identical |
EN ISO 16017-1:2000 | Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 1: Pumped sampling (ISO 16017-1:2000) |
ISO 16017-1:2000 | Indoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography — Part 1: Pumped sampling |
ISO 16000-3:2011 | Indoor air — Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air — Active sampling method |
ISO 16000-6:2011 | Indoor air Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.