HD 621 S1:1996/A1:2001
Current
The latest, up-to-date edition.
MV IMPREGNATED PAPER INSULATED DISTRIBUTION CABLES OF RATED VOLTAGES OF 3.8/6.6 KV TO 19/33 KV
05-07-2001
PART 1 General requirements
PART 2 Additional test methods
PART 3 Impregnated paper insulated cable-single core,
also pre-assembled
3-A Single core draining or non-draining paper
insulated cable - unarmoured; with or without
thermoplastic sheath (Type 3A)
3-B Single core cables with paper insulation,
non-draining
3-C Impregnated paper insulated Gables - single
core cables
3-E Single core cables 12/20 kV and 18/30 kV
3-F Single core cables, also pre-assembled
3-G Cables with paper insulation - draining -
unarmoured - PVC or PE sheathed - single core
3-I Cables with PE sheath
3-J-1 Single core and SL type paper insulated cables
with lead sheath (up to and including 12,7/22 kV)
3-J-2 Single core and SL type paper insulated cables
with lead sheath (19/33 kV)
PART 4 Impregnated paper insulated Gables - three core
4-A Multicore draining or non-draining paper insulated
cable - belted of screened cores - one or three
metallic sheaths - armoured or unarmoured -
thermoplastic sheath or not
4-B Multicore cables with paper insulation, non
draining
4-C Impregnated paper insulated cable - belted H and
SL type cables
4-D Belted multicore cables with polypropylene yarn
serving, or PVC or polyethylene sheath
4-E Armoured three-core cables with lead sheaths
12/20 kV and 18/30 kV and three-core cables
12/15 kV non-radial field
4-F Multicore Gables (Belted cables; three screened
cores - one lead sheath; three metallic sheathed
cores - one outer covering)
4-G-1 Impregnated paper insulated cable - three core
draining paper insulated cable - screened cores,
one metallic sheath - airmoured or unarmoured
serving, PE or PVC sheath
4-G-2 Impregnated paper insulated Gable - three core
draining paper insulated cable - belted, one
metallic sheath - armoured or unarmoured serving,
PE or PVC sheath
4-H-1 Three-core belted and screened Gables, with lead
sheath and steel tape armour
4-H-2 Three-core SL steel armoured cables
4-I Cables with one lead sheath (Type 4I-1) and with
three lead sheaths (Type 4I-2) and with sheaths of
PE
4-J-1 Three core cables with lead sheath (19/33 kV)
4-J-2 Three core cables with lead sheath, up to and
including 12,7/22 kV
4-J-3 Three core cables with aluminium sheath
4-K Armoured three core Gables with lead sheaths
and a rated voltage 23/40 kV
States the general requirements applicable to these cables, unless otherwise specified.
Committee |
CLC/TC 20
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
NEN HD 621 : 1996 AMD 1 2001 | Identical |
VDE 0276-621 : 1997 | Identical |
SN HD 621 : S1 AMD 1 2001 | Identical |
DIN VDE 0276-621 : 1997 | Identical |
UNE-HD 621-4E:1997 | Identical |
UNE-HD 621-3E:1997 | Identical |
NBN HD 621 : 1997 AMD 1 2001 | Identical |
UNE-HD 621-1:1997 | Identical |
PN HD 621 : 2003 | Identical |
UNE-HD 621-0:1997 | Identical |
CEI 20-77 : 2006 | Identical |
I.S. HD 621:1999 | Identical |
BS 7894:2003 | Identical |
DIN VDE 0276-621 : 1997 | Corresponds |
BS 7888-2:1998 | LV and MV accessories for power cables with rated voltage from 0.6/1 kV (<i>U</i><sub>m</sub>=1.2 kV) up to and including 20.8/36 kV (<i>U</i><sub>m</sub>=42 kV) Methods of test |
BS EN 50363-9-1:2005 | Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous insulating compounds. Cross-linked polyvinyl chloride (XLPVC) |
CEI 20-62/2 : 2006 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION |
CEI 20-62/1 : 2006 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION |
EN 50363-10-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 10-1: Miscellaneous sheathing compounds - Cross-linked polyvinyl chloride (XLPVC) |
EN 50363-9-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 9-1: Miscellaneous insulating compounds - Cross-linked polyvinyl chloride (XLPVC) |
BS 7888-4.1(2006) : 2006 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION |
98/232755 DC : DRAFT DEC 1998 | IEC 61936-1 - POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
03/315042 DC : DRAFT OCT 2003 | CENELEC HD 629.1 S2 - TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION |
HD 629.1 S2:2006/A1:2008 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION |
VDE 0276-634 : 1999 | TESTS ON INTERNAL GAS-PRESSURE CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (U[M] = 300 KV) |
DIN VDE 0276-633 : 1999 | TESTS ON OIL-FILLED (FLUID-FILLED), PAPER- AND POLYPROPYLENE PAPER LAMINATE-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (U[M] = 420 KV) |
VDE 0276-635 : 1999 | TESTS ON EXTERNAL GAS-PRESSURE (GAS COMPRESSION) CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (U[M] = 300 KV) |
DIN VDE 0276-634 : 1999 | TESTS ON INTERNAL GAS-PRESSURE CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (U[M] = 300 KV) |
DIN VDE 0276-635 : 1999 | TESTS ON EXTERNAL GAS-PRESSURE (GAS COMPRESSION) CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (U[M] = 300 KV) |
VDE 0276-633 : 1999 | TESTS ON OIL-FILLED (FLUID-FILLED), PAPER- AND POLYPROPYLENE PAPER LAMINATE-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (U[M] = 420 KV) |
I.S. HD 629.1:2006 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3.6/6(7.2) KV UP TO 20.8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION |
03/315043 DC : DRAFT OCT 2003 | CENELEC HD 629.2 S2 - TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION |
BS EN 50363-0:2011 | Insulating, sheathing and covering materials for low-voltage energy cables General introduction |
BS EN 50363-10-1:2005 | Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous sheathing compounds. Cross-linked polyvinyl chloride (XLPVC) |
I.S. EN 50363-9-1:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 9-1: MISCELLANEOUS INSULATING COMPOUNDS - CROSS-LINKED POLYVINYL CHLORIDE (XLPVC) |
I.S. EN 50363-0:2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW-VOLTAGE ENERGY CABLES - PART 0: GENERAL INTRODUCTION |
I.S. HD 629-2:2006 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION |
UNE-EN 50363-0:2011 | Insulating, sheathing and covering materials for low-voltage energy cables -- Part 0: General introduction |
HD 629.2 S2:2006/A1:2008 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION |
BS 7888-4.2(2006) : 2006 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION |
EN 50363-0:2011 | Insulating, sheathing and covering materials for low-voltage energy cables - Part 0: General introduction |