HD 60364-5-559:2012/A11:2017
Current
The latest, up-to-date edition.
LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-559: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - LUMINAIRES AND LIGHTING INSTALLATIONS
11-08-2017
FOREWORD
550 Introduction
551 Low-voltage generating sets
559 Luminaries and lighting installations
Annex A (informative) - List of notes concerning
certain countries
Annex B (informative) - Explanation of symbols
used in luminaries, in controlgear for
luminaries and in the installation of
the luminaries
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Annex ZB (normative) - Special national conditions
Annex ZC (informative) - A-deviations
Defines requirements for the selection and erection of low-voltage generating sets and for the selection and erection of luminaries and lighting installations intended to be part of the fixed installation.
Committee |
TC 64
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
NEN HD 60364-5-559 : 2012 AMD 11 2017 | Identical |
VDE 0100-559 : 2014-02 | Identical |
UNE 20460-5-559:2006 | Identical |
DIN VDE 0100-559 : 2014-02 | Identical |
SN HD 60364-5-559 : 2005 | Identical |
S.R. HD 60364-5-559:2012 | Identical |
PN HD 60364-5-559 : 2012 AMD 11 2017 | Identical |
I.S. HD 60364-5-559:2012 | Identical |
HD 60364-8-1:2015 | Low-voltage electrical installations - Part 8-1: Energy efficiency |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
UNE-EN 15869-2:2011 | Inland navigation vessels - Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz - Part 2: Onshore unit, safety requirements |
DIN EN 15869-2:2010-06 | INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 2: ONSHORE UNIT, SAFETY REQUIREMENTS |
UNE-HD 60364-8-1:2015 | Low-voltage electrical installations - Part 8-1: Energy efficiency |
UNI EN 15869-2 : 2010 | INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE-PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 2: ONSHORE UNIT, SAFETY REQUIREMENTS |
I.S. EN 15869-2:2010 | INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 2: ONSHORE UNIT, SAFETY REQUIREMENTS |
S.R. HD 60364-8-1:2015 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 8-1: ENERGY EFFICIENCY |
BS EN 15869-2:2010 | Inland navigation vessels. Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz Onshore unit, safety requirements |
EN 15869-2:2010 | Inland navigation vessels - Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz - Part 2: Onshore unit, safety requirements |
NF EN 60079-30-1 : 2007 | EXPLOSIVE ATMOSPHERES - PART 30-1: ELECTRICAL RESISTANCE TRACE HEATING - GENERAL AND TESTING REQUIREMENTS |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 546:1950 | Specification. Two-pole and earthing-pin plugs, socket-outlets and socket-outlet adaptors |
IEC 60364-4-43:2008 | Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent |
IEC 60364-7-712:2017 | Low voltage electrical installations - Part 7-712: Requirements for special installations or locations - Solar photovoltaic (PV) power supply systems |
IEC 60702-1:2002+AMD1:2015 CSV | Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables |
HD 60364-4-43:2010 | Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent |
EN 60598-2-13:2006/A2:2016 | LUMINAIRES - PART 2-13: PARTICULAR REQUIREMENTS - GROUND RECESSED LUMINAIRES (IEC 60598-2-13:2006/A2:2016) |
IEC 60364-7-717:2009 | Low-voltage electrical installations - Part 7-717: Requirements for special installations or locations - Mobile or transportable units |
EN 61048:2006/A1:2016 | AUXILIARIES FOR LAMPS - CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - GENERAL AND SAFETY REQUIREMENTS (IEC 61048:2006/A1:2015) |
EN 60702-1:2002/A1:2015 | MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES (IEC 60702-1:2002/A1:2015) |
IEC 60050-195:1998 | International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock |
IEC 61048:2006+AMD1:2015 CSV | Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 60331-11:1999+AMD1:2009 CSV | Tests for electric cables under fire conditions - Circuit integrity - Part 11: Apparatus - Fire alone at a flame temperature of at least 750 °C |
HD 60364-4-42 : 2011 AMD 1 2015 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS (IEC 60364-4-42:2010/A1:2014) |
BS 1363-2(1995) : 1995 | 13 A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS - PART 2: SPECIFICATION FOR 13 A SWITCHED AND UNSWITCHED SOCKET-OUTLETS |
IEC 60670-21:2004+AMD1:2016 CSV | Boxes and enclosures for electrical accessories for household andsimilar fixed electrical installations - Part 21: Particular requirements for boxes and enclosures with provision for suspensionmeans |
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV | Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control |
IEC 60050-845:1987 | International Electrotechnical Vocabulary (IEV) - Part 845: Lighting |
HD 60364-4-41:2017/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
BS 7001:1988 | Specification for interchangeability and safety of a standardized luminaire supporting coupler |
IEC 61347-1:2015 RLV | Lamp controlgear - Part 1: General and safety requirements |
BS 6972:1988 | Specification for general requirements for luminaire supporting couplers for domestic, light industrial and commercial use |
IEC 60570:2003+AMD1:2017 CSV | Electrical supply track systems for luminaires |
ISO 8528-12:1997 | Reciprocating internal combustion engine driven alternating current generating sets — Part 12: Emergency power supply to safety services |
IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
IEC 60332-1-1:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulatedwire or cable - Apparatus |
IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
BS EN 60309-2 : 1999 | PLUGS, SOCKET-OUTLETS AND COUPLERS FOR INDUSTRIAL PURPOSES - PART 2: DIMENSIONAL INTERCHANGEABILITY REQUIREMENTS FOR PIN AND CONTACT-TUBE ACCESSORIES |
HD 60364-1:2008/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 1: FUNDAMENTAL PRINCIPLES, ASSESSMENT OF GENERAL CHARACTERISTICS, DEFINITIONS |
DIN VDE 0710-14 : 1982 | LUMINAIRES WITH OPERATING VOLTAGES BELOW 1000 V; LUMINAIRES FOR BUILDING-IN INTO FURNITURE |
IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
IEC 60598-2-13:2006+AMD1:2011+AMD2:2016 CSV | Luminaires - Part 2-13: Particular requirements - Ground recessedluminaires |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
BS 1363-4(1995) : 1995 | 13 A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS - PART 4: SPECIFICATION FOR 13 A FUSED CONNECTION UNITS SWITCHED AND UNSWITCHED |
HD 60364-7-712:2016 | Low-voltage electrical installations - Part 7-712: Requirements for special installations or locations - Photovoltaic (PV) systems |
IEC 60331-21:1999 | Tests for electric cables under fire conditions - Circuit integrity - Part 21: Procedures and requirements - Cables of rated voltage up to and including 0,6/1,0 kV |
BS EN 50438:2013 | Requirements for micro-generating plants to be connected in parallel with public low-voltage distribution networks |
IEC 60598-2-22:2014+AMD1:2017 CSV | Luminaires - Part 2-22: Particular requirements - Luminaires for emergency lighting |
IEC 61535:2009+AMD1:2012 CSV | Installation couplers intended for permanent connection in fixedinstallations |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
IEC 60598-2-24:2013 | Luminaires - Part 2-24: Particular requirements - Luminaires with limited surface temperatures |
IEC 61557-12:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 12: Performance measuring and monitoring devices (PMD) |
EN 61535:2009/A1:2013 | INSTALLATION COUPLERS INTENDED FOR PERMANENT CONNECTION IN FIXED INSTALLATIONS (IEC 61535:2009/A1:2012) |
EN 60670-21:2007 | Boxes and enclosures for electrical accessories for household and similar fixed electrical installations - Part 21: Particular requirements for boxes and enclosures with provision for suspension means |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 60155:1993 | Glow-starters for fluorescent lamps |
IEC 60598-2-14:2009 | Luminaires - Part 2-14: Particular requirements - Luminaires for cold cathode tubular discharge lamps (neon tubes) and similar equipment |
IEC 60364-4-42:2010+AMD1:2014 CSV | Low-voltage electrical installations - Part 4-42: Protection forsafety - Protection against thermal effects |
HD 60364-7-717:2010/AC:2014 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-717: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - MOBILE OR TRANSPORTABLE UNITS |
EN 60598-2-22:2014/AC:2016-09 | LUMINAIRES - PART 2-22: PARTICULAR REQUIREMENTS - LUMINAIRES FOR EMERGENCY LIGHTING (IEC 60598-2-22:2014/COR2:2016) |
IEC 60702-2:2002+AMD1:2015 CSV | Mineral insulated cables and their terminations with a rated voltagenot exceeding 750 V - Part 2: Terminations |
EN 60702-2:2002/A1:2015 | MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 2: TERMINATIONS (IEC 60702-2:2002/A1:2015) |
IEC 60364-5-52:2009 | Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.