HB 37.4-1994
Current
The latest, up-to-date edition.
Handbook of Australian fire Standards Building materials, products and construction (Reconfirmed 2016)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
18-07-1994
Provides a summary of information on fire, tests and flammability relevant to building materials, products and construction, referring to appropriate Australian Standards.
Committee |
FP-018
|
DocumentType |
Handbook
|
ISBN |
0 7262 8981 7
|
Pages |
33
|
ProductNote |
Reconfirmed 27/05/2016.This standard has been reconfirmed in Australia in 2016 and remains current in New Zealand. Reconfirmation Notice 27/05/2016
|
PublisherName |
Standards Australia
|
Status |
Current
|
This part of the Handbook deals generally with matters relating to fire and fire tests concerning building materials, products and construction.This document lists individual Standards and Codes published by Standards Australia, and identifies appropriate procedures and documents prepared by other Australian and overseas organizations. This document is a general guide directing users to Standards dealing in detail with specific areas of fire hazard assessment, fire protection and fire regulation.The Handbook does not provide mandatory requirements on fire matters but advises the user on the applicability of State, Territory and local government regulations.NOTES:1 The Building Code of Australia (BCA) calls up most of the fire test methods and related Standards needed to define requirements and levels of performance for buildings.2 The International Maritime Organization (IMO) has a number of fire test methods that are used for ship construction. Appendix A lists several of these IMO Resolutions.
First published as SAA HB37.4-1994.
AS 3784.1-1990 | Coatings for fire protection of building elements - Guide to selection and installation of sprayed mineral coatings |
AS 1905.2-1989 | Components for the protection of openings in fire-resistant walls (known as the SAA Fire Door Code) - Fire-resistant roller shutters |
AS 2201.2-1992 | Intruder alarm systems - Central stations |
AS 2461-1981 | Mineral wool thermal insulation - Loose fill |
AS 2376.2-1981 | Plastics building sheets Glass fibre reinforced polyester (GRP) |
AS/NZS 2243.8:2006 | Safety in laboratories - Fume cupboards |
AS 2376.1-1980 | Plastics building sheets - Extruded PVC |
AS 2243.10-1993 | Safety in laboratories - Storage of chemicals |
AS 2714-1993 | The storage and handling of hazardous chemical materials - Class 5.2 substances (organic peroxides) |
AS/NZS 2122.2:1999 | Methods of test for determining combustion propagation characteristics of plastics - Determination of minimum oxygen concentration for flame propagation following top surface ignition of vertically orientated specimens |
AS 4073-1993 | Urea-formaldehyde foam thermal insulation - In situ set foam |
AS 1366.1-1992 | Rigid cellular plastics sheets for thermal insulation Rigid cellular polyurethane (RC/PUR) (Reconfirmed 2018) |
AS 1530.5-1989 | Methods for fire tests on building materials, components and structures Test for piloted ignitability |
AS 2924-1987 | Decorative thermosetting laminated sheets |
AS/NZS 2243.10:2004 | Safety in laboratories Storage of chemicals |
AS 2243.8-1992 | Safety in laboratories Fume cupboards |
AS 2419.1-1994 | Fire hydrant installations System design, installation and commissioning |
AS 1530.3-1989 | Methods for fire tests on building materials, components and structures Simultaneous determination of ignitability, flame propagation, heat release and smoke release |
AS 2201.2-2004 | Intruder alarm systems Monitoring centres |
AS 1366.2-1992 | Rigid cellular plastics sheets for thermal insulation Rigid cellular polyisocyanurate (RC/PIR) (Reconfirmed 2018) |
AS 4072.1-2005 | Components for the protection of openings in fire-resistant separating elements Service penetrations and control joints (Reconfirmed 2016) |
AS 1266-1986 | Fire control plans for ships |
AS 4072.1-1992 | Components for the protection of openings in fire-resistant separating elements - Service penetrations and control joints |
AS 1668.1-1991 | The use of mechanical ventilation and air-conditioning in buildings - Fire and smoke control |
AS 3959-1999 | Construction of buildings in bushfire-prone areas |
AS/NZS 1530.3:1999 | Methods for fire tests on building materials, components and structures Simultaneous determination of ignitability, flame propagation, heat release and smoke release (Reconfirmed 2016) |
AS 1366.3-1992 | Rigid cellular plastics sheets for thermal insulation Rigid cellular polystyrene - Moulded (RC/PS - M) (Reconfirmed 2018) |
AS 1635.19.1-1974 | Methods of testing pressure sensitive adhesive tape Flammability |
AS 1720.4-2006 | Timber structures Fire resistance for structural adequacy of timber members |
AS 3860-1991 | Fixed guideway people movers |
AS 1530.4-1990 | Methods for fire tests on building materials, components and structures Fire-resistance tests of elements of building construction |
AS 1903 TO 1904-1976 | Reflective foil laminate |
AS 2462-1981 | Cellulosic fibre thermal insulation |
AS 1720.4-1990 | Timber structures Fire-resistance of structural timber members |
AS 1668.2-1991 | The use of mechanical ventilation and air-conditioning in buildings Mechanical ventilation for acceptable indoor-air quality |
AS 2463-1981 | Sea grass bulk thermal insulation |
AS 2122.1-1993 | Combustion characteristics of plastics Determination of flame propagation - Surface ignition of vertically oriented specimens of cellular plastics |
AS 1905.1-2005 | Components for the protection of openings in fire-resistant walls Fire-resistant doorsets |
AS 3961-2005 | The storage and handling of liquefied natural gas |
AS/NZS 1668.1:1998 | The use of ventilation and airconditioning in buildings Fire and smoke control in multi-compartment buildings |
AS 2484.1-1990 | Fire - Glossary of terms Fire tests (Reconfirmed 2016) |
AS 1905.2-2005 | Components for the protection of openings in fire-resistant walls Fire-resistant roller shutters (Reconfirmed 2016) |
AS 1905.1-1990 | Components for the protection of openings in fire-resistant walls Fire-resistant doorsets |
AS 1530.4-2005 | Methods for fire tests on building materials, components and structures Fire-resistance test of elements of construction |
AS 2419.1-2005 | Fire hydrant installations System design, installation and commissioning |
AS 1366.4-1989 | Rigid cellular plastics sheets for thermal insulation Rigid cellular polystyrene - Extruded (RC/PS-E) (Reconfirmed 2018) |
AS 1530.1-1994 | Methods for fire tests on building materials, components and structures Combustibility test for materials (Reconfirmed 2016) |
AS 3742-1990 | Mineral wool thermal insulation - Batt and blanket |
AS 3959-1991 | Construction of buildings in bushfire-prone areas |
AS 1530.2-1993 | Methods for fire tests on building materials, components and structures Test for flammability of materials (Reconfirmed 2016) |
AS 2122.2-1978 | Combustion propagation characteristics of plastics Determination of minimum oxygen concentration for flame propagation following top surface ignition of vertically oriented specimens |
AS 3961-1991 | Liquefied natural gas - Storage and handling |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.