ENV 13381-4:2002
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Test methods for determining the contribution to the fire resistance of structural members - Part 4: Applied protection to steel members
07-03-2023
10-07-2002
Foreword
1 Scope
2 Normative references
3 Terms and definitions, symbols and units
4 Test equipment
5 Test conditions
6 Test specimens
7 Installation of the test specimens
8 Conditioning of the test specimens
9 Application of instrumentation
10 Test procedure
11 Test results
12 Test report
13 Assessment
14 Report of the assessment
15 Limits of the applicability of the results of the
assessment
Annex A (normative) Test method to the smouldering fire
or slow heating curve
Annex B (normative) The applicability of the results of
the assessment to sections other than 'I' or 'H'
sections
Annex C (normative) Measurement of properties of fire
protection materials
Annex D (normative) Fixing of thermocouples to steel work
and routing of cables
Annex E (normative) Correction for discrepancies in thickness
between loaded and equivalent unloaded sections
Annex F (normative) Assessment methodology: Differential
equation analysis (variable lambda approach)
Annex G (normative) Assessment methodology: Differential
equation analysis (constant lambda approach)
Annex H (normative) Assessment methodology: Numerical
regression analysis
Annex J (normative) Assessment methodology: Graphical
presentation
Bibliography
This part of this European Prestandard specifies a test method for determining the contribution made by applied fire protection systems to the fire resistance of structural steel members, which can be used as beams, columns or tension members. The evaluation is designed to cover a range of thicknesses of the applied fire protection material, a range of steel sections, characterized by their section factors, a range of design temperatures and a range of valid fire protection classification periods.This European Prestandard applies to fire protection materials where the gap between the material and the flange faces of the steel member is less than 5 mm in size. Otherwise, the test methods in prENV 13381-1 or prENV 13381-2, as appropriate, apply.This European Prestandard contains the fire test which specifies the tests which should be carried out to determine the ability of the fire protection system to remain coherent and fixed to the steelwork, and to provide data on the thermal characteristics of the fire protection system, when exposed to the standard temperature/time curve specified in EN 1363-1.In special circumstances, where specified in national building regulations, there can be a need to subject reactive protection material to a smouldering curve. The test for this and the special circumstances for its use are described in annex A.The fire test methodology makes provision for the collection and presentation of data which can be used as direct input to the calculation of fire resistance of steel structural members in accordance with the procedures given in ENV 1993-1-2.This European Prestandard also contains the assessment which prescribes how the analysis of the test data should be made and gives guidance on the procedures by which interpolation should be undertaken.The assessment procedure is used to establish:a)on the basis of temperature data derived from testing loaded and unloaded sections, a correction factor and any pra
Committee |
CEN/TC 127
|
DocumentType |
Standard Recommendation
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
SN ENV 13381-4 : 2002 | Identical |
NEN NVN ENV 13381-4 : 2003 | Identical |
NBN ENV 13381-4 : 2002 | Identical |
PN ENV 13381-4 : 2004 | Identical |
I.S. ENV 13381-4:2002 | Identical |
DD ENV 13381-4:2002 | Identical |
UNI ENV 13381-4 : 2002 | Identical |
UNE-ENV 13381-4:2005 | Identical |
XP ENV 13381-4 : 2002 XP | Identical |
DIN V ENV 13381-4:2003-09 | Identical |
04/30124505 DC : 0 | EN 15080-8 - EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - PART 8: BEAMS |
CEN/TR 14819-2:2005 | Safety recommendations for cableway installations designed to carry persons - Prevention and fight against fire - Part 2: Other funicular railways and other installations |
BS EN 1999-1-2:2007 | Eurocode 9. Design of aluminium structures Structural fire design |
CEN/TR 14819-1:2004 | Safety recommendations for cableway installations designed to carry persons - Prevention and fight against fire - Part 1: Funicular railways in tunnels |
UNE-EN 13501-2:2009 | Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services |
DIN EN 1993-1-2:2010-12 | Eurocode 3: Design of steel structures - Part 1-2: General rules - Structural fire design (includes Corrigendum AC:2009) |
I.S. EN 1994-1-2:2005 | EUROCODE 4 - DESIGN OF COMPOSITE STEEL AND CONCRETE STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN |
I.S. CEN TR 14819-1:2004 | SAFETY RECOMMENDATIONS FOR CABLEWAY INSTALLATIONS DESIGNED TO CARRY PERSONS - PREVENTION AND FIGHT AGAINST FIRE - PART 1: FUNICULAR RAILWAYS IN TUNNELS |
PD CEN/TR 14819-2:2005 | Safety recommendations for cableway installations designed to carry persons. Prevention and fight against fire Other funicular railways and other installations |
I.S. EN 13381-6:2012 | TEST METHODS FOR DETERMINING THE CONTRIBUTION TO THE FIRE RESISTANCE OF STRUCTURAL MEMBERS - PART 6: APPLIED PROTECTION TO CONCRETE FILLED HOLLOW STEEL COLUMNS |
I.S. CEN TS 13381-1:2006 | TEST METHODS FOR DETERMINING THE CONTRIBUTION TO THE FIRE RESISTANCE OF STRUCTURAL MEMBERS - PART 1: HORIZONTAL PROTECTIVE MEMBRANES |
UNI CEN/TS 13381-1 : 2006 | TEST METHODS FOR DETERMINING THE CONTRIBUTION TO THE FIRE RESISTANCE OF STRUCTURAL MEMBERS - PART 1: HORIZONTAL PROTECTIVE MEMBRANES |
DD ENV 13381-2:2002 | Test methods for determining the contribution to the fire resistance of structural members Vertical protective membranes |
I.S. CEN TR 14819-2:2006 | SAFETY RECOMMENDATIONS FOR CABLEWAY INSTALLATIONS DESIGNED TO CARRY PERSONS - PREVENTION AND FIGHT AGAINST FIRE - PART 2: OTHER FUNICULAR RAILWAYS AND OTHER INSTALLATIONS |
UNI EN 1994-1-2 : 2014 | EUROCODE 4 - DESIGN OF COMPOSITE STEEL AND CONCRETE STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN |
UNI EN 1993-1-2 : 2005 | EUROCODE 3 - DESIGN OF STEEL STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN |
EN 13381-6:2012 | Test methods for determining the contribution to the fire resistance of structural members - Part 6: Applied protection to concrete filled hollow steel columns |
UNI EN 1999-1-2 : 2007 | EUROCODE 9 - DESIGN OF ALUMINIUM STRUCTURES - PART 1-2: STRUCTURAL FIRE DESIGN |
BS EN 13381-6:2012 | Test methods for determining the contribution to the fire resistance of structural members Applied protection to concrete filled hollow steel columns |
ENV 13381-2:2002 | Test methods for determining the contribution to the fire resistance of stuctural members - Part 2: Vertical protective membranes |
08/30166841 DC : DRAFT MAR 2008 | BS EN 13381-8 - TEST METHODS FOR DETERMINING THE CONTRIBUTION TO THE FIRE RESISTANCE OF STRUCTURAL MEMBERS - PART 8: APPLIED REACTIVE PROTECTION TO STEEL MEMBERS |
DIN EN 13381-6:2012-09 | Test methods for determining the contribution to the fire resistance of structural members - Part 6: Applied protection to concrete filled hollow steel columns |
I.S. EN 1999-1-2:2007 | EUROCODE 9 - DESIGN OF ALUMINIUM STRUCTURES - PART 1-2: STRUCTURAL FIRE DESIGN (INCLUDING IRISH NATIONAL ANNEX) |
I.S. ENV 13381-2:2002 | TEST METHODS FOR DETERMINING THE CONTRIBUTION TO THE FIRE RESISTANCE OF STRUCTURAL MEMBERS - PART 2: VERTICAL PROTECTIVE MEMBRANES |
BS EN 1994-1-2 : 2005 | EUROCODE 4 - DESIGN OF COMPOSITE STEEL AND CONCRETE STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN |
DD CEN/TS 13381-1:2005 | Test methods for determining the contribution to the fire resistance of structural members Horizontal protective membranes |
UNE-EN 1993-1-2:2016 | Eurocode 3: Design of steel structures - Part 1-2: General rules - Structural fire design |
UNE-EN 13381-6:2014 | Test methods for determining the contribution to the fire resistance of structural members - Part 6: Applied protection to concrete filled hollow steel columns |
PD CEN/TR 14819-1:2004 | Safety recommendations for cableway installations designed to carry persons. Prevention and fight against fire Funicular railways in tunnels |
DIN EN 1999-1-2:2010-12 | Eurocode 9: Design of aluminium structures - Part 1-2: Structural fire design (includes Corrigendum AC:2009) |
05/30134009 DC : DRAFT MAY 2005 | EN 15254-1 - EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 1: GENERAL |
UNI EN 13381-6 : 2012 | TEST METHODS FOR DETERMINING THE CONTRIBUTION TO THE FIRE RESISTANCE OF STRUCTURAL MEMBERS - PART 6: APPLIED PROTECTION TO CONCRETE FILLED HOLLOW STEEL COLUMNS |
UNE-EN 1994-1-2:2016 | Eurocode 4 - Design of composite steel and concrete structures - Part 1-2: General rules - Structural fire design. |
DIN EN 1994-1-2:2010-12 | Eurocode 4: Design of composite steel and concrete structures - Part 1-2: General rules - Structural fire design (includes Corrigendum AC:2008) |
BS EN 1993-1-2:2005 | Eurocode 3. Design of steel structures General rules - Structural fire design |
CEN/TS 13381-1:2005 | Test methods for determining the contribution to the fire resistance of structural members - Part 1: Horizontal protective membranes |
ISO 8421-2:1987 | Fire protection — Vocabulary — Part 2: Structural fire protection |
ENV 13381-2:2002 | Test methods for determining the contribution to the fire resistance of stuctural members - Part 2: Vertical protective membranes |
EN 10025:1990/A1:1993 | HOT ROLLED PRODUCTS OF NON-ALLOY STRUCTURAL STEELS - TECHNICAL DELIVERY CONDITIONS |
ISO 13943:2017 | Fire safety — Vocabulary |
EN ISO 13943:2017 | Fire safety - Vocabulary (ISO 13943:2017) |
EN 1363-1:2012 | Fire resistance tests - Part 1: General Requirements |
EN 1363-2:1999 | Fire resistance tests - Part 2: Alternative and additional procedures |
ENV 1993-1-2 : DRAFT 95 | EUROCODE 3 - DESIGN OF STEEL STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN |
IEC 60584-1:2013 | Thermocouples - Part 1: EMF specifications and tolerances |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.