EN ISO 22959:2009
Current
The latest, up-to-date edition.
Animal and vegetable fats and oils - Determination of polycyclic aromatic hydrocarbons by on-line donor-acceptor complex chromatography and HPLC with fluorescence detection (ISO 22959:2009)
15-05-2009
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Reagents, materials and standards
6 Apparatus
7 Sampling and preparation of the test sample
8 Sample preparation
9 Procedure
9.1 HPLC analysis
9.2 Identification of PAHs
10 Calculation of individual PAHs
11 Method validation data
11.1 Accuracy
11.2 Within-laboratory precision
11.3 Recovery
11.4 Dynamic range
11.5 Limit of quantification
12 Precision
12.1 International collaborative trial
12.2 Repeatability
12.3 Reproducibility
13 Test report
Annex A (informative) - Example of the individual parts
of an HPLC system
Annex B (informative) - Example of the operating conditions
of the pumps of the HPLC system
Annex C (informative) - Example of the operating conditions
of the column thermostat and the detector of the
HPLC system
Annex D (informative) - Example of the autosampler programme
of the HPLC system
Annex E (informative) - Tubing connections of the HPLC system
Annex F (informative) - Chromatogram of a standard calibration
sample
Annex G (informative) - Determination precision for a sunflower
oil, range 0,1 [mu]g/kg to 3,5 [mu]g/kg
Annex H (informative) - Determination precision for an olive
oil, range 0,1 [mu]g/kg to 3,5 [mu]g/kg
Annex I (informative) - Determination precision for a soybean
oil, range 0,1 [mu]g/kg to 3,5 [mu]g/kg
Annex J (informative) - Determination precision for a coconut
oil, range 0,1 [mu]g/kg to 3,5 [mu]g/kg
Annex K (informative) - Interlaboratory test
Bibliography
ISO 22959:2009 specifies a high performance liquid chromatographic (HPLC) procedure for the determination of polycyclic aromatic hydrocarbons (PAHs) in edible fats and oils.The method has been validated for coconut, olive, sunflower, and soybean oil, and is possibly applicable to other oils, dependent on the determination of appropriate parameters.The lowest level of quantification for the PAHs is 0,1 µg/kg. The lowest possible amount of each PAH which can be distinguished from the baseline noise has not been determined. The validated concentration range of the method is 0,1 µg/kg to 3,5 µg/kg for each individual PAH. For samples containing (light) PAH contents > 3,5 µg/kg, dilution to bring the contents into the validated range is possible. It is also possible to adjust the range of the calibration curves. However, ranges exceeding 3,5 µg/kg have not been validated.PAHs which can be determined by this method are: anthracene, phenanthrene, fluoranthene, pyrene, chrysene, benzo[a]anthracene, benzo[e]pyrene, benzo[a]pyrene, perylene, benzo[ghi]perylene, anthanthrene, dibenzo[a,h]anthracene, coronene, indeno[1,2,3-cd]pyrene, benzo[a]fluoranthene, benzo[b]fluoranthene, benzo[k]fluoranthene.
Committee |
CEN/TC 307
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
NS EN ISO 22959 : 2009 | Identical |
DIN EN ISO 22959:2009-10 | Identical |
NBN EN ISO 22959 : 2009 | Identical |
NF EN ISO 22959 : 2009 | Identical |
SN EN ISO 22959:2009 | Identical |
NEN EN ISO 22959 : 2009 | Identical |
ISO 22959:2009 | Identical |
UNE-EN ISO 22959:2010 | Identical |
I.S. EN ISO 22959:2009 | Identical |
UNI EN ISO 22959 : 2009 | Identical |
BS EN ISO 22959:2009 | Identical |
BS EN 16619:2015 | Food analysis. Determination of benzo[a]pyrene, benz[a]anthracene, chrysene and benzo[b]fluoranthene in foodstuffs by gas chromatography mass spectrometry (GC-MS) |
CEN/TS 16621:2014 | Food analysis - Determination of benzo[a]pyrene, benz[a]anthracene, chrysene and benzo[b]fluoranthene in foodstuffs by high performance liquid chromatography with fluorescence detection (HPLC-FD) |
I.S. EN 16619:2015 | FOOD ANALYSIS - DETERMINATION OF BENZO[A]PYRENE, BENZ[A]ANTHRACENE, CHRYSENE AND BENZO[B]FLUORANTHENE IN FOODSTUFFS BY GAS CHROMATOGRAPHY MASS SPECTROMETRY (GC-MS) |
DIN EN 16619:2015-06 | FOOD ANALYSIS - DETERMINATION OF BENZO[A]PYRENE, BENZ[A]ANTHRACENE, CHRYSENE AND BENZO[B]FLUORANTHENE IN FOODSTUFFS BY GAS CHROMATOGRAPHY MASS SPECTROMETRY (GC-MS) |
13/30272431 DC : 0 | BS EN 16619 - FOOD ANALYSIS - DETERMINATION OF BENZO[A]PYRENE, BENZ[A]ANTHRACENE, CHRYSENE AND BENZO[B]FLUORANTHENE IN FOODSTUFFS BY GAS CHROMATOGRAPHY MASS SPECTROMETRY (GC-MS) |
S.R. CEN/TS 16621:2014 | FOOD ANALYSIS - DETERMINATION OF BENZO[A]PYRENE, BENZ[A]ANTHRACENE, CHRYSENE AND BENZO[B]FLUORANTHENE IN FOODSTUFFS BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY WITH FLUORESCENCE DETECTION (HPLC-FD) |
EN 16619:2015 | Food analysis - Determination of benzo[a]pyrene, benz[a]anthracene, chrysene and benzo[b]fluoranthene in foodstuffs by gas chromatography mass spectrometry (GC-MS) |
UNE-EN 16619:2015 | Food analysis - Determination of benzo[a]pyrene, benz[a]anthracene, chrysene and benzo[b]fluoranthene in foodstuffs by gas chromatography mass spectrometry (GC-MS) |
PD CEN/TS 16621:2014 | Food analysis. Determination of benzo[a]pyrene, benz[a]anthracene, chrysene and benzo[b]fluoranthene in foodstuffs by high performance liquid chromatography with fluorescence detection (HPLC-FD) |
UNI CEN/TS 16621 : 2014 | Food analysis - Determination of benzo [a] pyrene, benzo [a] anthracene, chrysene and benzo [b] fluoranthene in food products by high resolution liquid chromatography with fluorescence detector (HPLC-FD) |
ISO 5725-1:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions |
ISO 5555:2001 | Animal and vegetable fats and oils — Sampling |
ISO 1042:1998 | Laboratory glassware — One-mark volumetric flasks |
ISO 5725-2:1994 | Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method |
ISO 661:2003 | Animal and vegetable fats and oils — Preparation of test sample |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.