EN ISO 11904-2:2004

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Acoustics - Determination of sound immission from sound sources placed close to the ear - Part 2: Technique using a manikin (ISO 11904-2:2004)

Superseded date

10-04-2021

Superseded by

EN ISO 11904-2:2021

Published date

01-11-2004

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Measurement principle
5 Instrumentation
  5.1 Manikin (head and torso simulator)
  5.2 Check of calibration
  5.3 Filters
6 Determination of free-field or diffuse-field related
  equivalent continuous A-weighted sound pressure level
  6.1 Measurement of manikin sound pressure level
  6.2 Conversion to free-field or diffuse-field related
      sound pressure level
  6.3 A-weighting and summation
7 Test report
Annex A (informative) Example of sources of measurement
                      uncertainty
Annex B (informative) Example of an uncertainty analysis
Bibliography

ISO 11904-2:2004 specifies basic framework measurement methods for sound immission from sound sources placed close to the ear. These measurements are carried out with a manikin, equipped with ear simulators including microphones. The measured values are subsequently converted into corresponding free-field or diffuse-field levels. The results are given as free-field related or diffuse-field related equivalent continuous A-weighted sound pressure levels. The technique is denoted the manikin technique.ISO 11904-2:2004 is applicable to exposure to sound from sources close to the ear, for example during equipment tests or at the workplace to sound from earphones or hearing protectors with audiocommunication facilities.ISO 11904-2:2004 is applicable in the frequency range from 20 Hz to 10 kHz. For frequencies above 10 kHz, ISO 11904-1 can be used.

Committee
CEN/TC 211
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

I.S. EN 50332-1:2013 SOUND SYSTEM EQUIPMENT: HEADPHONES AND EARPHONES ASSOCIATED WITH PERSONAL MUSIC PLAYERS - MAXIMUM SOUND PRESSURE LEVEL MEASUREMENT METHODOLOGY - PART 1: GENERAL METHOD FOR ONE PACKAGE EQUIPMENT
BS EN 50332-1:2013 Sound system equipment: Headphones and earphones associated with personal music players. Maximum sound pressure level measurement methodology General method for \'one package equipment\'
13/30281662 DC : 0 BS EN 50332-1 - SOUND SYSTEM EQUIPMENT: HEADPHONES AND EARPHONES ASSOCIATED WITH PORTABLE AUDIO EQUIPMENT - MAXIMUM SOUND PRESSURE LEVEL MEASUREMENT METHODOLOGY AND LIMIT CONSIDERATIONS - PART 1: GENERAL METHOD FOR "ONE PACKAGE EQUIPMENT"
PREN 50332-1 : DRAFT 2013 SOUND SYSTEM EQUIPMENT: HEADPHONES AND EARPHONES ASSOCIATED WITH PORTABLE AUDIO EQUIPMENT - MAXIMUM SOUND PRESSURE LEVEL MEASUREMENT METHODOLOGY AND LIMIT CONSIDERATIONS - PART 1: GENERAL METHOD FOR "ONE PACKAGE EQUIPMENT"
16/30348450 DC : 0 BS EN 13819-3 - HEARING PROTECTORS - TESTING - PART 3: SUPPLEMENTARY ACOUSTIC TEST METHOD
EN 50332-1:2013 Sound system equipment: Headphones and earphones associated with personal music players - Maximum sound pressure level measurement methodology - Part 1: General method for "one package equipment"

IEC 60942:2003 Electroacoustics - Sound calibrators
IEC 60711:1981 Occluded-ear simulator for the measurement of earphones coupled to the ear by ear inserts
IEC 60268-7:2010 Sound system equipment - Part 7: Headphones and earphones
EN 50332-1:2013 Sound system equipment: Headphones and earphones associated with personal music players - Maximum sound pressure level measurement methodology - Part 1: General method for "one package equipment"
IEC 60268-1:1985 Sound system equipment. Part 1: General
ISO 11904-1:2002 Acoustics — Determination of sound immission from sound sources placed close to the ear — Part 1: Technique using a microphone in a real ear (MIRE technique)
IEC 61260:1995 Electroacoustics - Octave-band and fractional-octave-band filters

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more