Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 744:1995

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Plastics piping and ducting systems - Thermoplastics pipes - Test method for resistance to external blows by the round-the-clock method

Superseded date

01-10-2017

Superseded by

EN ISO 3127:2017

Published date

11-04-1995

Sorry this product is not available in your region.

Committees responsible
National foreword
Method
Foreword
1 Scope
2 Definition
3 Principle
4 Apparatus
5 Test pieces
6 Conditioning
7 Procedure
8 Expression of results
9 Test report
Annex
A (informative) Evaluation of results from isolated
    batches
Tables
1 Dimensions for the nose of the striker
2 Mass of strikers
3 Number of equidistant lines to be drawn on the
    test pieces
4 Conditioning periods
5 Expression of TIR at 10% depending on the number of
    blows and failures
Figures
1 Typical falling weight testing machine
2 dimensions of strikers
3 Number of test pieces for 10% TIR (at 90% confidence
    level)

This standard specifies a method for determining the resistance to external blows of thermoplastics pipes with circular cross sections by using the round-the-clock method. The method is intended to be applied to isolated batches of pipe. For type testing and audit testing, 0 °C and/or -20 °C are applicable.

Committee
CEN/TC 155
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

Standards Relationship
DIN EN 744:1995-08 Identical
BS EN 744:1996 Identical
PN EN 744 : 1997 Identical
NS EN 744 : 1ED 1995 Identical
SN EN 744 : 1995 Identical
BS 2782-11.1108C(1996) : 1996 Identical
I.S. EN 744:1995 Identical
NBN EN 744 : 1995 Identical
NF EN 744 : 1995 Identical
NEN EN 744 : 1995 Identical
UNI EN 744 : 1997 Identical
UNE-EN 744:1997 ERRATUM Identical
UNE-EN 744:1996 Identical

UNI EN ISO 15877-2 : 2011 PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS - CHLORINATED POLY(VINYL CHLORIDE) (PVC-C) - PART 2: PIPES
BS EN ISO 1452-2:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure. Unplasticized poly(vinyl chloride) (PVC U) Pipes
ISO 7682:2003 Plastics piping systems for soil and waste discharge (low and high temperature) inside buildings — Acrylonitrile-butadiene-styrene (ABS)
08/30191153 DC : 0 BS EN 1555-4 - PLASTICS PIPING SYSTEMS FOR THE SUPPLY OF GASEOUS FUELS - POLYETHYLENE (PE) - PART 4: VALVES
ISO 19220:2004 Plastics piping systems for soil and waste discharge (low and high temperature) inside buildings Styrene copolymer blends (SAN + PVC)
17/30363921 DC : 0 BS EN 17176-2 - PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE GROUND DRAINAGE, SEWERAGE AND IRRIGATION UNDER PRESSURE - ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) - PART 2: PIPES
BS EN 13476-3 : 2007 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 3: SPECIFICATIONS FOR PIPES AND FITTINGS WITH SMOOTH INTERNAL AND PROFILED EXTERNAL SURFACE AND THE SYSTEM, TYPE B
BS EN 1566-1:2000 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure. Chlorinated poly(vinyl chloride) (PVC-C) Specification for pipes, fittings and the system
BS EN 1452-2 : 2000 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 2: PIPES
BS EN 1555-4:2011 Plastics piping systems for the supply of gaseous fuels. Polyethylene (PE) Valves
I.S. EN ISO 15877-2:2009 PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS - CHLORINATED POLY(VINYL CHLORIDE) (PVC-C) - PART 2: PIPES
EN 13566-2:2005 Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - Part 2: Lining with continuous pipes
DIN EN 1452-2:1999-09 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 2: PIPES
DIN EN 13476-2:2007-08 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 2: SPECIFICATIONS FOR PIPES AND FITTINGS WITH SMOOTH INTERNAL AND EXTERNAL SURFACE AND THE SYSTEM, TYPE A
DIN EN 13476-3:2015-11 (Draft) PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 3: SPECIFICATIONS FOR PIPES AND FITTINGS WITH SMOOTH INTERNAL AND PROFILED EXTERNAL SURFACE AND THE SYSTEM, TYPE B
07/30160790 DC : 0 BS EN 15632-1 - DISTRICT HEATING PIPES - PRE-INSULATED FLEXIBLE PIPE SYSTEMS - PART 1: CLASSIFICATION, GENERAL REQUIREMENTS AND TEST METHODS
08/30168675 DC : DRAFT JULY 2008 BS EN ISO 1452-2 - PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC U) - PART 2: PIPES
PREN 1329-1 : DRAFT 2013 PLASTICS PIPING SYSTEMS FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) WITHIN THE BUILDING STRUCTURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
07/30165577 DC : 0 BS EN 1852-1 - PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - POLYPROPYLENE (PP) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
BS 2782-11.1133C(1997) : 1997 PLASTICS PIPING SYSTEMS - THERMOPLASTICS VALVES - TEST METHOD FOR THE INTEGRITY OF A VALVE AFTER AN EXTERNAL BLOW
ISO 3633:2002 Plastics piping systems for soil and waste discharge (low and high temperature) inside buildings — Unplasticized poly(vinyl chloride) (PVC-U)
BS EN 15632-1 : 2009 DISTRICT HEATING PIPES - PRE-INSULATED FLEXIBLE PIPE SYSTEMS - PART 1: CLASSIFICATION, GENERAL REQUIREMENTS AND TEST METHODS
EN 1566-1:1998 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Chlorinated poly(vinyl chloride) (PVC-C) - Part 1: Specifications for pipes, fittings and the system
BS EN 1329-1 : 2014 PLASTICS PIPING SYSTEMS FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) WITHIN THE BUILDING STRUCTURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
NF EN 1555-4 : 2011 PLASTICS PIPING SYSTEMS FOR THE SUPPLY OF GASEOUS FUELS - POLYETHYLENE (PE) - PART 4: VALVES
EN 1565-1:1998 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Styrene copolymer blends (SAN+PVC) - Part 1: Specifications for pipes, fittings and the system
UNI EN 1555-4 : 2011 PLASTICS PIPING SYSTEMS FOR THE SUPPLY OF GASEOUS FUELS - POLYETHYLENE (PE) - PART 4: VALVES
DIN EN 13566-2:2006-02 PLASTICS PIPING SYSTEMS FOR RENOVATION OF UNDERGROUND NON-PRESSURE DRAINAGE AND SEWERAGE NETWORKS - PART 2: LINING WITH CONTINUOUS PIPES
BS EN 13566-2:2005 Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks Lining with continuous pipes
I.S. EN 1555-4:2011 PLASTICS PIPING SYSTEMS FOR THE SUPPLY OF GASEOUS FUELS - POLYETHYLENE (PE) - PART 4: VALVES
13/30280703 DC : 0 BS EN 1329-1 - PLASTICS PIPING SYSTEMS FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) WITHIN THE BUILDING STRUCTURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
NF EN ISO 1452-2 : 2010 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 2: PIPES
05/30131855 DC : DRAFT APR 2005 ISO 8773 - PLASTICS PIPING SYSTEMS FOR UNDERGROUND DRAINAGE AND SEWERAGE - POLYPROPYLENE (PP)
BS EN 13476-2:2007 Plastics piping systems for non-pressure underground drainage and sewerage. Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) Specifications for pipes and fittings with smooth internal and external surface and the system, Type A
06/30124428 DC : 0 EN 13598-2 - PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - UNPLASTICIZED POLY (VINYL CHLORIDE)(PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 2: SPECIFICATIONS FOR MANHOLES AND INSPECTION CHAMBERS IN TRAFFIC AREAS AND DEEP UNDERGROUND INSTALLATIONS
DIN EN ISO 1452-2:2010-04 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 2: Pipes (ISO 1452-2:2009)
03/102186 DC : DRAFT AUG 2003 EN 14758-1 - PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - POLYPROPYLENE WITH MINERAL MODIFIERS (PP-M) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
PREN 17176-2 : DRAFT 2017 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE GROUND DRAINAGE, SEWERAGE AND IRRIGATION UNDER PRESSURE - ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) - PART 2: PIPES
ISO 1452-2:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 2: Pipes
EN 1455-1:1999 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Acrylonitrile-butadiene-styrene (ABS) - Part 1: Requirements for pipes, fittings and the system
ISO 7671:2003 Plastics piping systems for soil and waste discharge (low and high temperature) inside buildings — Polypropylene (PP)
I.S. EN 1329-1:2014 PLASTICS PIPING SYSTEMS FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) WITHIN THE BUILDING STRUCTURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
I.S. EN ISO 1452-2:2009 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 2: PIPES
DIN EN 13476-1:2015-11 (Draft) PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 1: GENERAL REQUIREMENTS AND PERFORMANCE CHARACTERISTICS
DIN EN 1555-4:2011-07 Plastics piping systems for the supply of gaseous fuels - Polyethylene (PE) - Part 4: Valves
BS EN 1401-1:2009 Plastic piping systems for non-pressure underground drainage and sewerage. Unplasticized poly(vinyl chloride) (PVC-U) Specifications for pipes, fittings and the system
BS EN 1716:1997 Plastics piping systems. Polyethylene (PE) tapping tees. Test method for impact resistance of an assembled tapping tee
UNI EN 1401-1 : 2009 PLASTICS PIPING SYSTEMS FOR NON- PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
ISO 8770:2003 Plastics piping systems for soil and waste discharge (low and high temperature) inside buildings Polyethylene (PE)
UNE-EN 15632-1:2010 District heating pipes - Pre-insulated flexible pipe systems - Part 1: Classification, general requirements and test methods
02/121757 DC : DRAFT APR 2002 BS ISO 19220 - PLASTICS PIPING SYSTEMS FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) INSIDE BUILDINGS - STYRENE COPOLYMER BLENDS (SAN + PVC)
UNI EN 1329-1 : 2014 PLASTICS PIPING SYSTEMS FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) WITHIN THE BUILDING STRUCTURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
BS EN 13476-1:2007 Plastics piping systems for non-pressure underground drainage and sewerage. Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) General requirements and performance characteristics
ISO 4435:2003 Plastics piping systems for non-pressure underground drainage and sewerage Unplasticized poly(vinyl chloride) (PVC-U)
I.S. EN 1455-1:1999 PLASTICS PIPING SYSTEMS FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) WITHIN THE BUILDING STRUCTURE - ACRYLONITRILE-BUTADIENE-STYRENE (ABS) - PART 1: REQUIREMENTS FOR PIPES, FITTINGS AND THE SYSTEM
DIN EN 13476-2:2015-11 (Draft) PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 2: SPECIFICATIONS FOR PIPES AND FITTINGS WITH SMOOTH INTERNAL AND EXTERNAL SURFACE AND THE SYSTEM, TYPE A
BS EN 1455-1:2000 Plastics piping systems for soil and waste (low and high temperature) within the building structure. Acrylonitrile-butadiene-styrene (ABS) Specifications for pipes, fittings and the system
BS EN 1705:1997 Plastics piping systems. Thermoplastics valves. Test method for the integrity of a valve after an external blow
UNE-EN 1555-4:2011 Plastics piping systems for the supply of gaseous fuels - Polyethylene (PE) - Part 4: Valves
ISO 15493:2003 Plastics piping systems for industrial applications Acrylonitrile-butadiene-styrene (ABS), unplasticized poly(vinyl chloride) (PVC-U) and chlorinated poly(vinyl chloride) (PVC-C) Specifications for components and the system Metric series
BS EN ISO 15877-2 : 2009 PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS - CHLORINATED POLY(VINYL CHLORIDE) (PVC-C) - PART 2: PIPES
ISO 15877-2:2009 Plastics piping systems for hot and cold water installations — Chlorinated poly(vinyl chloride) (PVC-C) — Part 2: Pipes
EN 1401-1:2009 Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system
EN 1705:1996 Plastics piping systems - Thermoplastics valves - Test method for the integrity of a valve after an external blow
EN 1452-2 : 1999 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 2: PIPES
EN 1716:1997 Plastics piping systems - Polyethylene (PE) tapping tees - Test method for impact resistance of an assembled tapping tee
EN 15632-1:2009+A1:2014 District heating pipes - Pre-insulated flexible pipe systems - Part 1: Classification, general requirements and test methods
EN ISO 1452-2:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 2: Pipes (ISO 1452-2:2009)
02/121064 DC : DRAFT MAR 2002 PREN 13566-2 - PLASTICS PIPING SYSTEMS FOR RENOVATION OF UNDERGROUND NON-PRESSURE DRAINAGE AND SEWERAGE NETWORKS - PART 2: LINING WITH CONTINUOUS PIPES
UNI EN ISO 1452-2 : 2010 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 2: PIPES
DIN EN 15632-1:2015-03 District heating pipes - Pre-insulated flexible pipe systems - Part 1: Classification, general requirements and test methods (includes Amendment A1:2014)
PREN 1555-4 : DRAFT 2008 PLASTICS PIPING SYSTEMS FOR THE SUPPLY OF GASEOUS FUELS - POLYETHYLENE (PE) - PART 4: VALVES
EN 1555-4:2011 Plastics piping systems for the supply of gaseous fuels - Polyethylene (PE) - Part 4: Valves
ISO/TS 18226:2006 Plastics pipes and fittings — Reinforced thermoplastics pipe systems for the supply of gaseous fuels for pressures up to 4 MPa (40 bar)
EN 1329-1:2014+A1:2018 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the systems
I.S. EN 15632-1:2009 DISTRICT HEATING PIPES - PRE-INSULATED FLEXIBLE PIPE SYSTEMS - PART 1: CLASSIFICATION, GENERAL REQUIREMENTS AND TEST METHODS
DIN EN ISO 15877-2:2011-03 Plastics piping systems for hot and cold water installations - Chlorinated poly(vinyl chloride) (PVC-C) - Part 2: Pipes (ISO 15877-2:2009 + AMD 1:2010)
DIN EN 1401-1:2009-07 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
I.S. EN 1401-1:2009 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
BS EN ISO 15493 : 2003 PLASTICS PIPING SYSTEMS FOR INDUSTRIAL APPLICATIONS - ACRYLONITRILE-BUTADIENE-STYRENE (ABS), UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) AND CHLORINATED POLY(VINYL CHLORIDE) (PVC-C) - SPECIFICATIONS FOR COMPONENTS AND THE SYSTEM - METRIC SERIES (ISO 15493:2003)
BS EN 1565-1:2000 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure. Styrene copolymer blends (SAN + PVC) Specifications for pipes, fittings and the system

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.