EN 62282-3-200:2016
Current
The latest, up-to-date edition.
Fuel cell technologies - Part 3-200: Stationary fuel cell power systems - Performance test methods
11-03-2016
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions, operating process and symbols
4 Reference conditions
5 Item of performance test
6 Test preparation
7 Measurement instruments and measurement
methods
8 Test plan
9 Test methods and computation of test results
10 Test reports
Annex A (normative) - Uncertainty analysis
Annex B (normative) - Calculation of fuel heating
value
Annex C (normative) - Reference gas
Annex D (informative) - Maximum acceptable instantaneous
electric power output transient
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
IEC 62282-3-200:2015 covers operational and environmental aspects of the stationary fuel cell power systems performance. The test methods apply as follows:- power output under specified operating and transient conditions;- electrical and heat recovery efficiency under specified operating conditions;- environmental characteristics;- for example, exhaust gas emissions, noise, etc. under specified operating and transient conditions. This new edition includes the following significant technical changes with respect to the previous edition: a stabilization zone of +- 10 % for thermal output of 100 % response time is provided instead of the tests for thermal output of 90 % response time, while the tests for electric output of 90 % response time remain as an option; the calculations for the ramp rate in kW/s are deleted and only the calculations for the response time (s) remain.
Committee |
CLC/SR 105
|
DevelopmentNote |
Supersedes EN 62282-3-2. (01/2012)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Supersedes |
Standards | Relationship |
IEC 62282-3-200:2015 | Identical |
SS-EN 62282-3-200:2016 | Identical |
DIN EN 62282-3-200 : 2016 | Identical |
NF EN 62282-3-200 : 2016 | Identical |
I.S. EN 62282-3-200:2016 | Identical |
NEN EN IEC 62282-3-200 : 2016 | Identical |
VDE 0130-3-200 : 2016 | Identical |
NBN EN 62282-3-200 : 2012 | Identical |
PN EN 62282-3-200 : 2016 | Identical |
UNE-EN 62282-3-200:2012 | Identical |
UNE-EN 62282-3-200:2016 | Identical |
BS EN 62282-3-200:2016 | Identical |
CEI EN 62282-3-200 : 2016 | Identical |
SN EN 62282-3-200 : 2016 | Identical |
PNE-FprEN 62282-3-200 | Identical |
BS EN 62282-3-100:2012 | Fuel cell technologies Stationary fuel cell power systems. Safety |
CEI EN 62282-3-201 : 2014 | FUEL CELL TECHNOLOGIES - PART 3-201: STATIONARY FUEL CELL POWER SYSTEMS - PERFORMANCE TEST METHODS FOR SMALL FUEL CELL POWER SYSTEMS |
EN 62282-3-100:2012 | Fuel cell technologies - Part 3-100: Stationary fuel cell power systems - Safety |
CEI EN 62282-3-100 : 2012 | FUEL CELL TECHNOLOGIES - PART 3-100: STATIONARY FUEL CELL POWER SYSTEMS - SAFETY |
BS EN 62282-3-201:2017 | Fuel cell technologies Stationary fuel cell power systems. Performance test methods for small fuel cell power systems |
I.S. EN 62282-3-100:2012 | FUEL CELL TECHNOLOGIES - PART 3-100: STATIONARY FUEL CELL POWER SYSTEMS - SAFETY (IEC 62282-3-100:2012 (EQV)) |
UNE-EN 62282-3-201:2013 | Fuel cell technologies - Part 3-201: Stationary fuel cell power systems - Performance test methods for small fuel cell power systems |
I.S. EN 62282-3-201:2017 | FUEL CELL TECHNOLOGIES - PART 3-201: STATIONARY FUEL CELL POWER SYSTEMS - PERFORMANCE TEST METHODS FOR SMALL FUEL CELL POWER SYSTEMS |
EN 62282-3-201:2017 | Fuel cell technologies - Part 3-201: Stationary fuel cell power systems - Performance test methods for small fuel cell power systems |
ISO/TR 15916:2015 | Basic considerations for the safety of hydrogen systems |
EN 60688:2013 | Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals |
IEC 61672-2:2013+AMD1:2017 CSV | Electroacoustics - Sound level meters - Part 2: Pattern evaluation tests |
EN ISO 11541:2002 | Natural gas - Determination of water content at high pressure (ISO 11541:1997) |
ISO 3648:1994 | Aviation fuels — Estimation of net specific energy |
ISO 3744:2010 | Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Engineering methods for an essentially free field over a reflecting plane |
ISO 6976:2016 | Natural gas — Calculation of calorific values, density, relative density and Wobbe indices from composition |
ISO 14687-3:2014 | Hydrogen fuel Product specification Part 3: Proton exchange membrane (PEM) fuel cell applications for stationary appliances |
EN 60359:2002 | Electrical and electronic measurement equipment - Expression of performance |
EN 61672-2:2013/A1:2017 | ELECTROACOUSTICS - SOUND LEVEL METERS - PART 2: PATTERN EVALUATION TESTS (IEC 61672-2:2013/A1:2017) |
ISO 11086:1996 | Gas turbines — Vocabulary |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC TS 62282-1:2013 | Fuel cell technologies - Part 1: Terminology |
IEC 60688:2012 | Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals |
EN ISO 10523:2012 | Water quality - Determination of pH (ISO 10523:2008) |
EN 61000-4-7:2002/A1:2009 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-7: TESTING AND MEASUREMENT TECHNIQUES - GENERAL GUIDE ON HARMONICS AND INTERHARMONICS MEASUREMENTS AND INSTRUMENTATION, FOR POWER SUPPLY SYSTEMS AND EQUIPMENT CONNECTED THERETO (IEC 61000-4-7:2002/A1:2008) |
ISO 6975:1997 | Natural gas — Extended analysis — Gas-chromatographic method |
ISO 7935:1992 | Stationary source emissions — Determination of the mass concentration of sulfur dioxide — Performance characteristics of automated measuring methods |
IEC 62052-11:2003+AMD1:2016 CSV | Electricity metering equipment (a.c.) - General requirements, tests and test conditions - Part 11: Metering equipment |
ISO 8217:2017 | Petroleum products — Fuels (class F) — Specifications of marine fuels |
ISO 6060:1989 | Water quality — Determination of the chemical oxygen demand |
ISO 4677-1:1985 | Atmospheres for conditioning and testing Determination of relative humidity Part 1: Aspirated psychrometer method |
ISO 16622:2002 | Meteorology — Sonic anemometers/thermometers — Acceptance test methods for mean wind measurements |
ISO 11042-1:1996 | Gas turbines — Exhaust gas emission — Part 1: Measurement and evaluation |
ISO 11042-2:1996 | Gas turbines — Exhaust gas emission — Part 2: Automated emission monitoring |
EN 61672-1:2013 | Electroacoustics - Sound level meters - Part 1: Specifications |
EN ISO 3744:2010 | Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Engineering methods for an essentially free field over a reflecting plane (ISO 3744:2010) |
EN 50470-1:2006 | Electricity metering equipment (a.c.) - Part 1: General requirements, tests and test conditions - Metering equipment (class indexes A, B and C) |
ISO 11541:1997 | Natural gas Determination of water content at high pressure |
EN 62282-3-201:2017 | Fuel cell technologies - Part 3-201: Stationary fuel cell power systems - Performance test methods for small fuel cell power systems |
EN ISO 6975:2005 | Natural gas - Extended analysis - Gas-chromatographic method (ISO 6975:1997) |
IEC 61000-4-7:2002+AMD1:2008 CSV | Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto |
IEC 62053-22:2003+AMD1:2016 CSV | Electricity metering equipment (a.c.) - Particular Requirements - Part 22: Static meters for active energy (classes 0,2 S and 0,5 S) |
ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
IEC 60359:2001 | Electrical and electronic measurement equipment - Expression of performance |
ISO 5815-2:2003 | Water quality — Determination of biochemical oxygen demand after n days (BODn) — Part 2: Method for undiluted samples |
ISO 5348:1998 | Mechanical vibration and shock Mechanical mounting of accelerometers |
ISO 10849:1996 | Stationary source emissions — Determination of the mass concentration of nitrogen oxides — Performance characteristics of automated measuring systems |
ISO 10780:1994 | Stationary source emissions — Measurement of velocity and volume flowrate of gas streams in ducts |
EN 61028:1993/A2:1997 | ELECTRICAL MEASURING INSTRUMENTS - X-Y RECORDERS |
EN ISO 6976:2016 | Natural gas - Calculation of calorific values, density, relative density and Wobbe indices from composition (ISO 6976:2016) |
ISO 10523:2008 | Water quality — Determination of pH |
ISO 10396:2007 | Stationary source emissions — Sampling for the automated determination of gas emission concentrations for permanently-installed monitoring systems |
IEC 61028:1990 | Electrical measuring instruments - X-Y recorders |
ISO 4677-2:1985 | Atmospheres for conditioning and testing Determination of relative humidity Part 2: Whirling psychrometer method |
EN 61000-4-13:2002/A2:2016 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-13: TESTING AND MEASUREMENT TECHNIQUES - HARMONICS AND INTERHARMONICS INCLUDING MAINS SIGNALLING AT A.C. POWER PORT, LOW FREQUENCY IMMUNITY TESTS (IEC 61000-4-13:2002/A2:2015) |
IEC 60050-300:2001 | International Electrotechnical Vocabulary (IEV) - Part 300: Electrical and electronic measurements and measuring instruments - Part 311: General terms relating to measurements - Part 312: General terms relating to electrical measurements - Part 313: Types of electrical measuring instruments - Part 314: Specific terms according to the type of instrument |
IEC 62282-3-201:2017 | Fuel cell technologies - Part 3-201: Stationary fuel cell power systems - Performance test methods for small fuel cell power systems |
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV | Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests |
EN ISO 9000:2015 | Quality management systems - Fundamentals and vocabulary (ISO 9000:2015) |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
ISO 11632:1998 | Stationary source emissions — Determination of mass concentration of sulfur dioxide — Ion chromatography method |