FOREWORD
1 General
2 Normal and special service conditions
3 Terms and definitions
4 Ratings
5 Design and construction
6 Type tests
7 Routine tests
8 Guide to the selection of switchgear and
   controlgear
9 Information to be given with enquiries,
   tenders and orders
10 Transport, storage, installation, operation
   and maintenance
11 Safety
12 Influence of the product on the environment
Annex AA (normative) - Internal arc fault -
         Method to verify the internal arc
         classification (IAC)
Annex BB (normative) - Partial discharge measurement
Annex CC (informative) - Regional deviations
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications
Annex ZB (informative) - A-deviations

Describes requirements for prefabricated metal-enclosed Switchgear and controlgear for alternating current of rated voltages above 1 kV and up to and including 52 kV for indoor and outdoor installation, and for service frequencies up to and including 60 Hz.

Committee
TC 17AC
DevelopmentNote
Supersedes EN 60298 (04/2004) To be read in conjunction with EN 62271-1. (01/2012)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy
Supersedes

BS EN 62271-106:2011 High-voltage switchgear and controlgear Alternating current contactors, contactor-based controllers and motor-starters
13/30251586 DC : 0 BS EN 50123-6:2003/AMD 1 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 6: D.C. SWITCHGEAR ASSEMBLIES
DD CLC/TS 62271-304:2008 High-voltage switchgear and controlgear Design classes for indoor enclosed switchgear and controlgear for rated voltages above 1 kV up to and including 52 kV to be used in severe climatic conditions
11/30235280 DC : 0 BS EN 50152-1 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
PD CLC/TR 62271-208:2010 High-voltage switchgear and controlgear Methods to quantify the steady state, power-frequency electromagnetic fields generated by HV switchgear assemblies and HV/LV prefabricated substations
KTA 3705 : 2013(R2017) SWITCHGEAR FACILITIES, TRANSFORMERS AND DISTRIBUTION NETWORKS FOR THE ELECTRICAL POWER SUPPLY OF THE SAFETY SYSTEM IN NUCLEAR POWER PLANTS
I.S. EN 50123-6:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 6: D.C. SWITCHGEAR ASSEMBLIES
I.S. EN 62271-212:2017 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 212: COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATION (CEADS)
UNE-EN 60099-4:2016 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
UNE-EN 62271-212:2017 High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS)
EN 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
EN 62271-109:2009/A1:2013 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 109: ALTERNATING-CURRENT SERIES CAPACITOR BY-PASS SWITCHES (IEC 62271-109:2008/A1:2013)
EN 62271-201:2014 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
EN 62271-212:2017 High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS)
EN 62271-202:2014/AC:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION (IEC 62271-202:2014)
EN 50123-6 : 2003 AMD 1 2014 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 6: D.C. SWITCHGEAR ASSEMBLIES
UNE-EN 50123-6:2004 Railway applications - Fixed installations - D.C. switchgear -- Part 6: D.C. switchgear assemblies
UNE-EN 50152-2:2013 Railway applications - Fixed installations - Particular requirements for alternating current switchgear - Part 2: Disconnectors, earthing switches and switches with nominal voltage above 1 kV
I.S. EN 62271-107:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 107: ALTERNATING CURRENT FUSED CIRCUIT-SWITCHERS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV (IEC 62271-107:2012 (EQV))
BS EN 62271-206:2011 High-voltage switchgear and controlgear Voltage presence indicating systems for rated voltages above 1 kV and up to and including 52 kVkV and up to and including 52 kV
CLC/TS 62271-304:2008 High-voltage switchgear and controlgear - Part 304: Design classes for indoor enclosed switchgear and controlgear for rated voltages above 1 kV up to and including 52 kV to be used in severe climatic conditions
I.S. EN 62271-202:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION
CEI EN 60099-5 : 2014 SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS
CEI EN 60099-4 : 2015 SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS
I.S. EN 60099-4:2014 SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS
BS EN 62271-107:2012 High-voltage switchgear and controlgear Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV
CLC/TR 62271-208:2010 High-voltage switchgear and controlgear - Part 208: Methods to quantify the steady state, power-frequency electromagnetic fields generated by HV switchgear assemblies and HV/LV prefabricated substations
CEI CLC/TR 62271-208 : 2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 208: METHODS TO QUANTIFY THE STEADY STATE, POWER-FREQUENCY ELECTROMAGNETIC FIELDS GENERATED BY HV SWITCHGEAR ASSEMBLIES AND HV/LV PREFABRICATED SUBSTATIONS
BS EN 62271-100 : 2009 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 100: ALTERNATING-CURRENT CIRCUIT-BREAKERS (IEC 62271-100:2008)
S.R. CLC/TR 62271-208:2010 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 208: METHODS TO QUANTIFY THE STEADY STATE, POWER-FREQUENCY ELECTROMAGNETIC FIELDS GENERATED BY HV SWITCHGEAR ASSEMBLIES AND HV/LV PREFABRICATED SUBSTATIONS
PREN 50152-1 : DRAFT 2011 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
I.S. EN 62271-206:2011 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 206: VOLTAGE PRESENCE INDICATING SYSTEMS FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
CEI EN 62271-107 : 2013 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 107: ALTERNATING CURRENT FUSED CIRCUIT-SWITCHERS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV
I.S. EN 50152-2:2012 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
EN 61936-1 : 2010 AMD 1 2014 POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES (IEC 61936-1:2010/A1:2014)
S.R. CLC/TS 62271-304:2008 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 304: DESIGN CLASSES FOR INDOOR ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV TO BE USED IN SEVERE CLIMATIC CONDITIONS
UNE-EN 62271-202:2015 High-voltage switchgear and controlgear - Part 202: High-voltage/low-voltage prefabricated substation
UNE-EN 62271-107:2012 High-voltage switchgear and controlgear - Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV
EN 50532:2010 Compact Equipment Assembly for Distribution Substations (CEADS)
I.S. EN 50532:2010 COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATIONS (CEADS)
BS EN 60099-9:2014 Surge arresters Metal-oxide surge arresters without gaps for HVDC converter stations
11/30235283 DC : 0 BS EN 50152-2 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
BS EN 60099-5:2013 Surge arresters Selection and application recommendations
UNE-EN 50152-1:2013 Railway applications - Fixed installations - Particular requirements for alternating current switchgear - Part 1: Circuit-breakers with nominal voltage above 1 kV
BS EN 50123-6 : 2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 6: D.C. SWITCHGEAR ASSEMBLIES
BS EN 50152-2:2012 Railway applications. Fixed installations. Particular requirements for alternating current switchgear Disconnectors, earthing switches and switches with nominal voltage above 1 kV
I.S. EN 50152-1:2012 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
EN 62271-100 : 2009 AMD 2/COR 18 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 100: ALTERNATING-CURRENT CIRCUIT-BREAKERS (IEC 62271-100:2008/A2:2017/COR1:2018)
CEI EN 62271-206 : 2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 206: VOLTAGE PRESENCE INDICATING SYSTEMS FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
PREN 50152-2 : DRAFT 2011 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
CEI EN 50152-2 : 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
I.S. EN 61936-1:2010 POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES
I.S. EN 60099-5:2013 SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS (IEC 60099-5:2013 (EQV))
BS EN 62271-212:2017 High-voltage switchgear and controlgear Compact Equipment Assembly for Distribution Substation (CEADS)
BS EN 50532:2010 Compact equipment assembly for distribution substations (CEADS)
09/30202403 DC : 0 BS EN 50532 - COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATIONS (CEADS)
UNE-EN 50532:2011 Compact Equipment Assembly for Distribution Substations (CEADS)
BS EN 61936-1 : 2010 POWER INSTALLATIONS EXCEEDING 1 KV A.C - PART 1: COMMON RULES
UNE-EN 62271-106:2012 High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters
UNE-EN 61936-1:2012 Power installations exceeding 1 kV a.c. -- Part 1: Common rules
EN IEC 60099-5:2018 Surge arresters - Part 5: Selection and application recommendations
BS EN 50152-1 : 2012 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
CEI CLC/TS 62271-304 : 2009 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 304: DESIGN CLASSES FOR INDOOR ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV TO BE USED IN SEVERE CLIMATI CONDITIONS
I.S. EN 62271-106:2011 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 106: ALTERNATING CURRENT CONTACTORS, CONTACTOR-BASED CONTROLLERS AND MOTOR-STARTERS (IEC 62271-106:2011 (EQV))
BS EN 62271-201:2014 High-voltage switchgear and controlgear AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
EN 62271-106:2011 High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters
I.S. EN IEC 60099-5:2018 SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS
I.S. EN 60099-9:2014 SURGE ARRESTERS - PART 9: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR HVDC CONVERTER STATIONS
CEI EN 60099-9 : 2015 SURGE ARRESTERS - PART 9: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR HVDC CONVERTER STATIONS
BS EN 60099-4:2014 Surge arresters Metal-oxide surge arresters without gaps for a.c. systems
I.S. EN 62271-100:2009 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 100: ALTERNATING-CURRENT CIRCUIT-BREAKERS
I.S. EN 62271-109:2009 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 109: ALTERNATING-CURRENT SERIES CAPACITOR BY-PASS SWITCHES (IEC 62271-109:2008 (EQV))
BS EN 62271-202:2014 High-voltage switchgear and controlgear High-voltage/low-voltage prefabricated substation
EN 50152-2:2012 Railway applications - Fixed installations - Particular requirements for alternating current switchgear - Part 2: Disconnectors, earthing switches and switches with nominal voltage above 1 kV
EN 62271-107:2012 High-voltage switchgear and controlgear - Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV
EN 60099-9:2014 Surge arresters - Part 9: Metal-oxide surge arresters without gaps for HVDC converter stations
EN 62271-206:2011 High-voltage switchgear and controlgear - Part 206: Voltage presence indicating systems for rated voltages above 1 kV and up to and including 52 kV
EN 50152-1 : 2012 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
EN 60099-5:2013 Surge arresters - Part 5: Selection and application recommendations

IEC 60243-1:2013 Electric strength of insulating materials - Test methods - Part 1: Tests at power frequencies
EN 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers
IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
CLC/TR 62271-303:2009 High-voltage switchgear and controlgear - Part 303: Use and handling of sulphur hexafluoride (SF6)
IEC 60724:2000+AMD1:2008 CSV Short-circuit temperature limits of electric cables with rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV)
IEC 62271-105:2012 High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV
IEC 62271-201:2014 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
EN 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
IEC 60050-601:1985 International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General
IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
EN 62271-203:2012 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
EN 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
EN 62271-201:2014 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
EN 62271-102:2002/AC:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES (IEC 62271-102:2001/A2:2013)
IEC 60909-0:2016 Short-circuit currents in three-phase a.c. systems - Part 0: Calculation of currents
IEC 60470:1999 High-voltage alternating current contactors and contactor-based motor-starters
IEEE 400.2-2013 REDLINE IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)(less than 1 Hz)
EN 60270:2001/A1:2016 HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015)
EN 62271-103:2011 High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV
IEC TS 62271-304:2008 High-voltage switchgear and controlgear - Part 304: Design classes for indoor enclosed switchgear and controlgear for rated voltages above 1 kV up to and includuing 52 kV to be used in severe climatic conditions
ISO/IEC Guide 51:2014 Safety aspects — Guidelines for their inclusion in standards
EN 60470:2000/corrigendum Jun. 2000 HIGH-VOLTAGE ALTERNATING CURRENT CONTACTORS AND CONTACTOR-BASED MOTOR STARTERS
IEC 62271-103:2011 High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
EN 60909-0:2016 Short-circuit currents in three-phase a.c. systems - Part 0: Calculation of currents
IEC 62271-203:2011 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
IEC 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
CLC/TS 62271-304:2008 High-voltage switchgear and controlgear - Part 304: Design classes for indoor enclosed switchgear and controlgear for rated voltages above 1 kV up to and including 52 kV to be used in severe climatic conditions
EN 60243-1:2013 Electric strength of insulating materials - Test methods - Part 1: Tests at power frequencies
IEEE C37.20.7-2007 REDLINE IEEE Guide for Testing Metal-Enclosed Switchgear Rated Up to 38 kV for Internal Arcing Faults
IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
IEC TR 62271-303:2008 High-voltage switchgear and controlgear - Part 303: Use and handling of sulphur hexafluoride (SF<sub>6</sub>)
EN 60059:1999/A1:2009
IEC 60059:1999+AMD1:2009 CSV IEC standard current ratings
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
EN 62271-105:2012 High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV
EN 50187 : 96 AC 96 GAS-FILLED COMPARTMENTS FOR A.C. SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
IEC 62271-102:2001+AMD1:2011+AMD2:2013 CSV High-voltage switchgear and controlgear - Part 102: Alternatingcurrent disconnectors and earthing switches

Access your standards online with a subscription

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Sorry this product is not available in your region.