FOREWORD
1 General
2 Normal and special service conditions
3 Terms and definitions
4 Ratings
5 Design and construction
6 Type tests
7 Routine tests
8 Guide for the selection of fused circuit-switchers
9 Information to be given with enquiries, tenders
   and orders
10 Rules for transport, storage, installation, operation
   and maintenance
11 Safety
12 Influence of the product on the environment
Annex A (informative) - Applicability of the rated
       take-over current test duty
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Bibliography

IEC 62271-107:2012 applies to three-pole operated units for distribution systems that are functional assemblies of a circuit-switcher and current-limiting fuses designed so as to be capable of: - breaking, at the rated recovery voltage, any load or fault current up to and including the rated short-circuit breaking current; - making, at the rated voltage, circuits to which the rated short-circuit breaking current applies. This second edition cancels and replaces the first edition, published in 2005. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition. - the reference to IEC 60694 has been changed to IEC 62271-1; - the new clauses and subclauses from IEC 62271-1 have been added and where necessary new wording has been provided; - the normative references have been updated: IEC 60265-1 to IEC 62271-103, IEC 60787 to IEC/TR 60787, IEC 60466 to IEC 62271-201, and IEC/TR 60787 was moved to the bibliography; - the figures and tables have been placed in the document where they are first cited; - the numbering of figures and tables has been changed to obtain the correct order; - the definition of NSDD was deleted. This definition is included in IEC 62271-1; - the acceptance criteria have been aligned with 6.101.4 of IEC 62271-103:2011; - the various provisions expressed about 'extension of the validity of type tests' have been grouped under 6.103: some of the rules were duplicated in Clauses 6 and 8, and it seems better fitted to deal within each type test sub-clause only with the type test to be performed. Conditions have not been changed, but the wording is clearer; - new numbering of subclauses in Clauses 8 and 9 to avoid conflict with clauses from IEC 62271-1.

Committee
CLC/TC 17AC
DevelopmentNote
To be read in conjunction with EN 60694. (03/2006)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers
IEC TR 60787:2007 Application guide for the selection of high-voltage current- limiting fuse-links for transformer circuits
IEC 62271-200:2011 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
IEC 62271-105:2012 High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV
IEC 62271-201:2014 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
EN 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
EN 62271-201:2014 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
EN 62271-102:2002/AC:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES (IEC 62271-102:2001/A2:2013)
IEC 60282-1:2009+AMD1:2014 CSV High-voltage fuses - Part 1: Current-limiting fuses
EN 62271-103:2011 High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV
IEC 62271-103:2011 High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV
IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
EN 60282-1:2009/A1:2014 HIGH-VOLTAGE FUSES - PART 1: CURRENT-LIMITING FUSES (IEC 60282-1:2009)
EN 62271-105:2012 High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV
IEEE C37.016-2006 IEEE Standard for AC High Voltage Circuit Switchers rated 15.5kV through 245kV
EN 62271-200:2012/AC:2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011)
IEC 62271-102:2001+AMD1:2011+AMD2:2013 CSV High-voltage switchgear and controlgear - Part 102: Alternatingcurrent disconnectors and earthing switches

Access your standards online with a subscription

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Sorry this product is not available in your region.