FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Normal and special service conditions
5 Ratings
6 Design and construction
7 Type tests
8 Routine tests
9 Guide to the selection of switchgear and
   controlgear (informative)
10 Information to be given with enquiries, tenders
   and orders (informative)
11 Transport, storage, installation, operating
   instructions and maintenance
12 Safety
13 Influence of the product on the environment
Annex A (normative) - Identification of test objects
Annex B (informative) - Determination of the equivalent
        RMS value of a short-time current during a
        short-circuit of a given duration
Annex C (normative) - Method for the weatherproofing
        test for outdoor switchgear and controlgear
Annex D (informative) - References for auxiliary and
        control circuit components
Annex E (normative) - Tolerances on test quantities
        during tests
Annex F (informative) - Information and technical
        requirements to be given with enquiries, tenders
        and orders
Annex G (informative) - List of symbols
Annex H (informative) - Electromagnetic compatibility
        on site
Annex I (informative) - List of notes concerning certain
        countries
Annex J (informative) - Extension of validity of type
        tests
Annex K (informative) - Exposure to pollution
Bibliography
Annex ZA (normative) - Normative references to international
         Publications with their corresponding European publications

IEC62271-1:2017 applies to AC switchgear and controlgear designed for indoor and/or outdoor installation and for operation at service frequencies up to and including 60Hz and having rated voltages above 1000V.This document applies to all high-voltage switchgear and controlgear except as otherwise specified in the relevant IEC standards for the particular type of switchgear and controlgear.This second edition cancels and replaces the first edition published in 2007 and Amendment 1:2011. This edition constitutes a technical revision.This edition includes the following significant technical changes with respect to the previous edition:New numbering in accordance with ISO/IECdirectives,Part2 (2016) and IEEE Std.C37.100.1.4.1.2 a) The normal service condition for indoor switchgear is limited to one range of40°C to-5°C.4.1.3 a) The normal service condition for outdoor switchgear is limited to one range of40°C to-25°C.4.2.2: The specifications from IEC60071-2:1996 are adopted for altitude correction factors above1000 m.5.2.2: Range I, the rated voltage of40,5kV is added Series I Table1; Table2 and Table4 are updated on recommendation of the US National Committee.6.8: New subclause added for manual operated actuators consistent with “Man Machine Interface” recommendations of IEC60447 .7.2.6.1:Insert the wording regarding preliminary impulses across open vacuum interrupters according to the result of IEC17/1026/RQ.7.3: Changed the requirement for radio interference voltage to a rated voltage level of 245kV and above, instead of 123kV and above. This change is based on reported positive test and service experience of utility representatives in the maintenance team of this standard.7.5.6, Table14:a. Introduced the distinction of parts in “OG” (oxidizing gas) or in “NOG” (not oxidizing gas) replacing the former “air” and “SF6”;b. Increased the allowable temperature rise for some parts in groups1 and2 of Table14 according to IECTR60943;c. Expanded the definition of allowable temperature rise for categories of accessible surfaces with reference to IECGuide117. See also Point15 in 7.5.6.2.7.5.6.2: Point5 is modified to clarify the introduction of “OG” and “NOG” gas.7.10: Some tests were removed because the relevant test standards of IEC60068 series were modified or withdrawn.7.11.3: The acceptance criteria for X-radiation testing are modified to recognize higher rated vacuum interrupters.Former informative AnnexH: Corrosion is deleted, the content is part ofIECTR62271-306.New AnnexJ(informative): Added informative guidelines for the extension of validity of type testsNew AnnexK(informative): Added informative guidelines about exposure to pollution

Committee
CLC/TC 17AC
DevelopmentNote
Supersedes EN 60694. (12/2008)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy
Supersedes

UNE-EN 50124-1:2017 Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
CLC/TS 50562:2011 Railway applications - Fixed installations - Process, measures and demonstration of safety for electric traction systems
BS EN 62271-106:2011 High-voltage switchgear and controlgear Alternating current contactors, contactor-based controllers and motor-starters
CEI EN 62271-207 : 2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
DD CLC/TS 62271-304:2008 High-voltage switchgear and controlgear Design classes for indoor enclosed switchgear and controlgear for rated voltages above 1 kV up to and including 52 kV to be used in severe climatic conditions
BS EN 60038:2011 CENELEC standard voltages
11/30235280 DC : 0 BS EN 50152-1 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
CEI EN 62271-204 : 2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 204: RIGID GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGES ABOVE 52 KV
15/30298489 DC : 0 BS EN 50124-1 - RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT
I.S. EN 62271-105:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 105: ALTERNATING CURRENT SWITCH-FUSE COMBINATIONS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV (IEC 62271-105:2012 (EQV))
BS EN 62271-203:2012 High-voltage switchgear and controlgear Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
I.S. EN 50110-1:2013 OPERATION OF ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS
I.S. EN IEC 62271-110:2018 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 110: INDUCTIVE LOAD SWITCHING
CEI CLC/TS 50562 : 2012 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PROCESS, MEASURES AND DEMONSTRATION OF SAFETY FOR ELECTRIC TRACTION SYSTEMS
I.S. EN 60137:2017 INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V
I.S. EN 61850-3:2014 COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 3: GENERAL REQUIREMENTS
I.S. EN 62271-212:2017 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 212: COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATION (CEADS)
UNE-EN 60099-4:2016 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
EN 60137:2017 Insulated bushings for alternating voltages above 1 000 V
EN 62271-112:2013 High-voltage switchgear and controlgear - Part 112: Alternating current high-speed earthing switches for secondary arc extinction on transmission lines
UNE-EN 62271-212:2017 High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS)
UNE-EN 62271-203:2013 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
EN 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
EN 50052:2016 High-voltage switchgear and controlgear - Gas-filled cast aluminium alloy enclosures
EN 62271-109:2009/A1:2013 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 109: ALTERNATING-CURRENT SERIES CAPACITOR BY-PASS SWITCHES (IEC 62271-109:2008/A1:2013)
EN 62271-3:2015 High-voltage switchgear and controlgear - Part 3: Digital interfaces based on IEC 61850
EN 62271-201:2014 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
EN 62271-212:2017 High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS)
EN 62271-103:2011 High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV
EN 60143-1:2015/AC:2017-05 Series capacitors for power systems - Part 1: General
EN 60038:2011 CENELEC STANDARD VOLTAGES (IEC 60038:2009, MODIFIED)
EN 62271-202:2014/AC:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION (IEC 62271-202:2014)
EN 61850-3:2014 Communication networks and systems for power utility automation - Part 3: General requirements
EN 62271-211:2014/AC:2017-09 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 211: DIRECT CONNECTION BETWEEN POWER TRANSFORMERS AND GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-211:2014/COR2:2017)
EN 62271-105:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 105: ALTERNATING CURRENT SWITCH-FUSE COMBINATIONS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV (IEC 62271-105:2012)
EN 62271-102:2002/AC:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES (IEC 62271-102:2001/A2:2013)
CEI EN 62271-4 : 2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4: HANDLING PROCEDURES FOR SULPHUR HEXAFLUORIDE (SF[6]) AND ITS MIXTURES
CEI EN 62271-112 : 2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 112: ALTERNATING CURRENT HIGH-SPEED EARTHING SWITCHES FOR SECONDARY ARC EXTINCTION ON TRANSMISSION LINES
CEI EN 62271-105 : 2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 105: ALTERNATING CURRENT SWITCH-FUSE COMBINATIONS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV
UNE-EN 62271-204:2012 High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV
I.S. EN 62271-4:2013 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4: HANDLING PROCEDURES FOR SULPHUR HEXAFLUORIDE (SF[6]) AND ITS MIXTURES (IEC 62271-4:2013 (EQV))
UNE-EN 50152-2:2013 Railway applications - Fixed installations - Particular requirements for alternating current switchgear - Part 2: Disconnectors, earthing switches and switches with nominal voltage above 1 kV
I.S. EN 62271-107:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 107: ALTERNATING CURRENT FUSED CIRCUIT-SWITCHERS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV (IEC 62271-107:2012 (EQV))
BS EN 60143-2:2013 Series capacitors for power systems Protective equipment for series capacitor banks
11/30244384 DC : 0 BS EN 60038 - CENELEC STANDARD VOLTAGES
BS EN 62271-206:2011 High-voltage switchgear and controlgear Voltage presence indicating systems for rated voltages above 1 kV and up to and including 52 kVkV and up to and including 52 kV
BS EN 62271-211:2014 High-voltage switchgear and controlgear Direct connection between power transformers and gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
EN 50562:2018 Railway applications - Fixed installations - Process, protective measures and demonstration of safety for electric traction systems
BS EN 62271-109 : 2009 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 109: ALTERNATING-CURRENT SERIES CAPACITOR BY-PASS SWITCHES
I.S. EN 62271-3:2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: DIGITAL INTERFACES BASED ON IEC 61850
PD CLC/TR 62271-303:2009 High-voltage switchgear and controlgear Use and handling of sulfur hexafluoride (SF6)
CLC/TS 62271-304:2008 High-voltage switchgear and controlgear - Part 304: Design classes for indoor enclosed switchgear and controlgear for rated voltages above 1 kV up to and including 52 kV to be used in severe climatic conditions
16/30314785 DC : 0 BS EN 50562 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PROCESS, PROTECTIVE MEASURES AND DEMONSTRATION OF SAFETY FOR ELECTRIC TRACTION SYSTEMS
BS EN 50052:2016 High-voltage switchgear and controlgear. Gas-filled cast aluminium alloy enclosures
I.S. EN IEC 62613-1:2018 PLUGS, SOCKET-OUTLETS AND SHIP COUPLERS FOR HIGH-VOLTAGE SHORE CONNECTION SYSTEMS (HVSC-SYSTEMS) - PART 1: GENERAL REQUIREMENTS
PREN 50124-1 : DRAFT 2015 RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT
I.S. EN 62271-211:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 211: DIRECT CONNECTION BETWEEN POWER TRANSFORMERS AND GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV
PREN 60038 : DRAFT 2011 CENELEC STANDARD VOLTAGES
I.S. EN 62146-1:2014 GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS - PART 1: GENERAL
BS EN 60137:2017 Insulated bushings for alternating voltages above 1000 V
I.S. EN 62271-202:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION
BS EN 62271-100 : 2009 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 100: ALTERNATING-CURRENT CIRCUIT-BREAKERS (IEC 62271-100:2008)
CEI EN 60099-5 : 2014 SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS
EN 50124-1:2017 Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
CEI EN 62271-201 : 2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 201: AC SOLID-INSULATION ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
CEI EN 60099-4 : 2015 SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS
EN 61936-1 : 2010 AMD 1 2014 POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES (IEC 61936-1:2010/A1:2014)
I.S. EN 50124-1:2017 RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT
I.S. EN 50052:2016 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - GAS-FILLED CAST ALUMINIUM ALLOY ENCLOSURES
UNE-EN 62271-200:2012 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
EN IEC 62271-110:2018/AC:2018-03 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 110: INDUCTIVE LOAD SWITCHING (IEC 62271-110:2017/COR1:2017, IEC 62271-110:2017/COR2:2018
UNE-EN 62271-207:2012 High-voltage switchgear and controlgear - Part 207: Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV
CEI EN 50110-1 : 2014 OPERATION OF ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS
BS EN 62271-3:2015 High-voltage switchgear and controlgear Digital interfaces based on IEC 61850
BS EN 62271-107:2012 High-voltage switchgear and controlgear Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV
BS EN 62271-4:2013 High-voltage switchgear and controlgear Handling procedures for sulphur hexafluoride (SF<sub>6</sub>) and its mixtures
CEI EN 50052 : 1998 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - GAS-FILLED CAST ALUMINIUM ALLOY ENCLOSURES
BS EN 62271-103:2011 High-voltage switchgear and controlgear Switches for rated voltages above 1 kV up to and including 52 kV
UNE-EN 60137:2011 Insulated bushings for alternating voltages above 1 000 V
BS EN 62271-102 : 2002 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES
UNE-EN 60038:2012 CENELEC standard voltages
BS EN 50110-1:2013 Operation of electrical installations General requirements
15/30303100 DC : 0 BS EN 50052 - CAST ALUMINIUM ALLOY ENCLOSURES FOR GAS-FILLED HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR
UNE-EN 62271-103:2012 High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV
CEI EN 60143-2 : 2014 SERIES CAPACITORS FOR POWER SYSTEMS - PART 2: PROTECTIVE EQUIPMENT FOR SERIES CAPACITOR BANKS
I.S. EN 62271-207:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-207:2012 (EQV))
BS EN 62271-200:2012 High-voltage switchgear and controlgear AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
PREN 50152-1 : DRAFT 2011 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
BS EN 62146-1 : 2014 GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS - PART 1: GENERAL (IEC 62146-1:2013)
I.S. EN 50562:2018 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PROCESS, PROTECTIVE MEASURES AND DEMONSTRATION OF SAFETY FOR ELECTRIC TRACTION SYSTEMS
I.S. EN 62271-206:2011 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 206: VOLTAGE PRESENCE INDICATING SYSTEMS FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
CEI EN 62271-107 : 2013 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 107: ALTERNATING CURRENT FUSED CIRCUIT-SWITCHERS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV
I.S. EN 60099-4:2014 SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS
I.S. EN 50152-2:2012 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
EN 62271-200:2012/AC:2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011)
S.R. CLC/TS 62271-304:2008 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 304: DESIGN CLASSES FOR INDOOR ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV TO BE USED IN SEVERE CLIMATIC CONDITIONS
UNE-EN 62271-202:2015 High-voltage switchgear and controlgear - Part 202: High-voltage/low-voltage prefabricated substation
UNE-EN 62271-100:2011 High-voltage switchgear and controlgear -- Part 100: Alternating-current circuit-breakers
UNE-EN 62271-107:2012 High-voltage switchgear and controlgear - Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV
EN 62271-104:2015 High-voltage switchgear and controlgear - Part 104: Alternating current switches for rated voltages higher than 52 kV
EN 50532:2010 Compact Equipment Assembly for Distribution Substations (CEADS)
I.S. EN 62271-112:2013 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 112: ALTERNATING CURRENT HIGH-SPEED EARTHING SWITCHES FOR SECONDARY ARC EXTINCTION ON TRANSMISSION LINES (IEC 62271-112:2013 (EQV))
CLC/TR 62271-303:2009 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 303: USE AND HANDLING OF SULPHUR HEXAFLUORIDE (SF[6])
I.S. EN 62271-204:2011 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 204: RIGID GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGE ABOVE 52 KV (IEC 62271-204:2011 (EQV))
PREN 50052 : DRAFT 2015 CAST ALUMINIUM ALLOY ENCLOSURES FOR GAS-FILLED HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR
BS EN 62271-112:2013 High-voltage switchgear and controlgear Alternating current high-speed earthing switches for secondary arc extinction on transmission lines
I.S. EN 50532:2010 COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATIONS (CEADS)
I.S. EN 60143-2:2013 SERIES CAPACITORS FOR POWER SYSTEMS - PART 2: PROTECTIVE EQUIPMENT FOR SERIES CAPACITOR BANKS (IEC 60143-2:2012 (EQV))
BS EN 62271-104:2015 High-voltage switchgear and controlgear Alternating current switches for rated voltages higher than 52 kV
DD CLC/TS 50562:2011 Railway applications. Fixed Installations. Process, measures and demonstration of safety for electric traction systems
S.R. CLC/TR 62271-303:2009 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 303: USE AND HANDLING OF SULPHUR HEXAFLUORIDE (SF[6])
BS EN 60099-9:2014 Surge arresters Metal-oxide surge arresters without gaps for HVDC converter stations
BS EN 62271-207:2012 High-voltage switchgear and controlgear Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV
UNE-EN 50052:2017 High-voltage switchgear and controlgear - Gas-filled cast aluminium alloy enclosures
11/30235283 DC : 0 BS EN 50152-2 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
BS EN 60099-5:2013 Surge arresters Selection and application recommendations
UNE-EN 50152-1:2013 Railway applications - Fixed installations - Particular requirements for alternating current switchgear - Part 1: Circuit-breakers with nominal voltage above 1 kV
UNE-EN 62271-104:2015 High-voltage switchgear and controlgear - Part 104: Alternating current switches for rated voltages higher than 52 kV
UNE-EN 50110-1:2014 Operation of electrical installations - Part 1: General requirements
CEI EN 61850-3 : 2014 COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 3: GENERAL REQUIREMENTS
BS EN 50152-2:2012 Railway applications. Fixed installations. Particular requirements for alternating current switchgear Disconnectors, earthing switches and switches with nominal voltage above 1 kV
EN 62271-100 : 2009 AMD 2/COR 18 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 100: ALTERNATING-CURRENT CIRCUIT-BREAKERS (IEC 62271-100:2008/A2:2017/COR1:2018)
I.S. EN 50152-1:2012 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
I.S. EN 62271-100:2009 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 100: ALTERNATING-CURRENT CIRCUIT-BREAKERS
S.R. CLC/TS 50562:2011 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PROCESS, MEASURES AND DEMONSTRATION OF SAFETY FOR ELECTRIC TRACTION SYSTEMS
PREN 50562 : DRAFT 2016 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PROCESS, PROTECTIVE MEASURES AND DEMONSTRATION OF SAFETY FOR ELECTRIC TRACTION SYSTEMS
I.S. EN 62271-104:2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 104: ALTERNATING CURRENT SWITCHES FOR RATED VOLTAGES HIGHER THAN 52 KV
CEI EN 62271-206 : 2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 206: VOLTAGE PRESENCE INDICATING SYSTEMS FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
PREN 50152-2 : DRAFT 2011 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
CEI EN 50152-2 : 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
I.S. EN 61936-1:2010 POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES
I.S. EN 60099-5:2013 SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS (IEC 60099-5:2013 (EQV))
BS EN 62271-212:2017 High-voltage switchgear and controlgear Compact Equipment Assembly for Distribution Substation (CEADS)
BS EN 50532:2010 Compact equipment assembly for distribution substations (CEADS)
UNE-EN 62271-201:2015 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
09/30202403 DC : 0 BS EN 50532 - COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATIONS (CEADS)
UNE-EN 50532:2011 Compact Equipment Assembly for Distribution Substations (CEADS)
BS EN 61936-1 : 2010 POWER INSTALLATIONS EXCEEDING 1 KV A.C - PART 1: COMMON RULES
UNE-EN 62271-106:2012 High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters
UNE-EN 61936-1:2012 Power installations exceeding 1 kV a.c. -- Part 1: Common rules
EN 62271-204:2011 High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV
BS EN 62271-105:2012 High-voltage switchgear and controlgear Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV
BS EN 50152-1 : 2012 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
CEI EN 62271-203 : 2013 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV
BS EN 60143-1:2015 Series capacitors for power systems General
CEI CLC/TS 62271-304 : 2009 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 304: DESIGN CLASSES FOR INDOOR ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV TO BE USED IN SEVERE CLIMATI CONDITIONS
I.S. EN 62271-106:2011 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 106: ALTERNATING CURRENT CONTACTORS, CONTACTOR-BASED CONTROLLERS AND MOTOR-STARTERS (IEC 62271-106:2011 (EQV))
BS EN 61850-3:2014 Communication networks and systems for power utility automation General requirements
BS EN 62271-201:2014 High-voltage switchgear and controlgear AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
BS EN 50124-1:2017 Railway applications. Insulation coordination Basic requirements. Clearances and creepage distances for all electrical and electronic equipment
BS EN 62271-204:2011 High-voltage switchgear and controlgear Rigid gas-insulated transmission lines for rated voltage above 52 kV
I.S. EN 62271-102:2005 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES (IEC 62271-102:2001 (EQV))
EN 62271-106:2011 High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters
EN IEC 62613-1:2018 Plugs, socket-outlets and ship couplers for high-voltage shore connection systems (HVSC-Systems) - Part 1: General requirements
I.S. EN 60143-1:2015 SERIES CAPACITORS FOR POWER SYSTEMS - PART 1: GENERAL
BS EN 60099-4:2014 Surge arresters Metal-oxide surge arresters without gaps for a.c. systems
I.S. EN 62271-203:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-203:2011 (EQV))
UNE-EN 62271-4:2014 High-voltage switchgear and controlgear - Part 4: Handling procedures for sulphur hexafluoride (SF6) and its mixtures
CEI EN 60137 : 2009 INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V
I.S. EN 62271-200:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011 (EQV))
I.S. EN 62271-103:2011 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 103: SWITCHES FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV
I.S. EN 62271-201:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 201: AC SOLID-INSULATION ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
I.S. EN 62271-109:2009 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 109: ALTERNATING-CURRENT SERIES CAPACITOR BY-PASS SWITCHES (IEC 62271-109:2008 (EQV))
UNE-EN 62271-105:2013 High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV
BS EN 62271-202:2014 High-voltage switchgear and controlgear High-voltage/low-voltage prefabricated substation
EN 62271-207:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-207:2012)
EN 62271-4 : 2013 High-voltage switchgear and controlgear - Part 4: Handling procedures for sulphur hexafluoride (SF6) and its mixtures
EN 50152-2:2012 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
EN 62146-1:2014/A1:2016 GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS - PART 1: GENERAL (IEC 62146-1:2013/A1:2016)
EN 62271-107:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 107: ALTERNATING CURRENT FUSED CIRCUIT-SWITCHERS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV (IEC 62271-107:2012)
EN 60099-9:2014 Surge arresters - Part 9: Metal-oxide surge arresters without gaps for HVDC converter stations
EN 62271-206:2011 High-voltage switchgear and controlgear - Part 206: Voltage presence indicating systems for rated voltages above 1 kV and up to and including 52 kV
EN 60143-2:2013 Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks
EN 50152-1 : 2012 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
EN 62271-203:2012 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
EN 50110-1:2013 Operation of electrical installations - Part 1: General requirements
EN 60099-5:2013 Surge arresters - Part 5: Selection and application recommendations

EN 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
IEC 60480:2004 Guidelines for the checking and treatment of sulfur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use
IEC 60050-351:2013 International Electrotechnical Vocabulary (IEV) - Part 351: Control technology
IEC 60038:2009 IEC standard voltages
IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEC 60721-1:1990+AMD1:1992+AMD2:1995 CSV Classification of environmental conditions - Part 1: Environmental parameters and their severities
IEC 60050-131:2002 International Electrotechnical Vocabulary (IEV) - Part 131: Circuit theory
IEC 61936-1:2010+AMD1:2014 CSV Power installations exceeding 1 kV a.c. - Part 1: Common rules
EN 60376:2005 Specification of technical grade sulfur hexafluoride (SF6) for use in electrical equipment
IEC 60947-7-2:2009 Low-voltage switchgear and controlgear - Part 7-2: Ancillary equipment - Protective conductor terminal blocks for copper conductors
IEC 60730-2-9:2015 RLV Automatic electrical controls - Part 2-9: Particular requirements for temperature sensing controls
IEC 60228:2004 Conductors of insulated cables
IEC 60051-1:2016 Direct acting indicating analogue electrical measuring instruments and their accessories - Part 1: Definitions and general requirements common to all parts
IEC 61020-1:2009 Electromechanical switches for use in electrical and electronic equipment - Part 1: Generic specification
IEC 62271-207:2012 High-voltage switchgear and controlgear - Part 207: Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV
IEC 60050-811:1991 International Electrotechnical Vocabulary (IEV) - Part 811: Electric traction
IEC 60947-4-1:2009+AMD1:2012 CSV Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
IEEE C37.100.1-2007 IEEE Standard of Common Requirements for High Voltage Power Switchgear Rated Above 1000 V
EN 60085:2008 Electrical insulation - Thermal evaluation and designation
EN 61000-4-11:2004/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 60073:2002 Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
IEEE C37.122.5-2013 REDLINE IEEE Guide for Moisture Measurement and Control in SF6 Gas-Insulated Equipment
IEC 60050-605:1983 International Electrotechnical Vocabulary (IEV) - Part 605: Generation, transmission and distribution of electricity - Substations
IEC 60050-601:1985 International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General
IEC TR 60909-1:2002 Short-circuit currents in three-phase a.c. systems - Part 1: Factors for the calculation of short-circuit currents according to IEC 60909-0
IEC 60730-2-13:2017 Automatic electrical controls - Part 2-13: Particular requirements for humidity sensing controls
IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC GUIDE 117:2010 Electrotechnical equipment - Temperatures of touchable hot surfaces
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
IEC TR 60083:2015 Plugs and socket-outlets for domestic and similar general use standardized in member countries of IEC
IEC TS 60815-2:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems
EN 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60269-2:2013+AMD1:2016 CSV Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K
IEC 60051-4:1984 Direct acting indicating analogue electrical measuring instruments and their accessories. Part 4: Special requirements for frequency meters
EN 60480:2004 Guidelines for the checking and treatment of sulphur hexafluoride (SF6) taken from electrical equipment and specification for its re-use
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 60909-0:2016 Short-circuit currents in three-phase a.c. systems - Part 0: Calculation of currents
IEC 61000-4-17:1999+AMD1:2001+AMD2:2008 CSV Electromagnetic compatibility (EMC) - Part 4-17: Testing and measurement techniques - Ripple on d.c. input power port immunity test
EN 60512-2-2:2003 Connectors for electronic equipment - Tests and measurements - Part 2-2: Electrical continuity and contact resistance tests - Test 2b: Contact resistance - Specified test current method
IEC TR 62271-300:2006 High-voltage switchgear and controlgear - Part 300: Seismic qualification of alternating current circuit-breakers
IEC 61810-1:2015 Electromechanical elementary relays - Part 1: General and safety requirements
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV Low-voltage fuses - Part 1: General requirements
IEC 62326-1:2002 Printed boards - Part 1: Generic specification
IEC 60376:2005 Specification of technical grade sulfur hexafluoride (SF<sub>6</sub>) for use in electrical equipment
IEC 60947-7-1:2009 Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors
IEEE C37.81-1989 IEEE Guide for Seismic Qualification of Class 1E Metal-Enclosed Power Switchgear Assemblies
IEC 60050-551:1998 International Electrotechnical Vocabulary (IEV) - Part 551: Power electronics
IEC TS 62271-210:2013 High-voltage switchgear and controlgear - Part 210: Seismic qualification for metal enclosed and solid-insulation enclosed switchgear and controlgear assemblies for rated voltages above 1 kV and up to and including 52 kV
EN 61810-7:2006 Electromechanical elementary relays - Part 7: Test and measurement procedures
EN 60270:2001/A1:2016 HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015)
IEC 61810-7:2006 Electromechanical elementary relays - Part 7: Test and measurement procedures
EN 60507:2014 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC TS 62271-304:2008 High-voltage switchgear and controlgear - Part 304: Design classes for indoor enclosed switchgear and controlgear for rated voltages above 1 kV up to and includuing 52 kV to be used in severe climatic conditions
IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
IEC 60051-2:1984 Direct acting indicating analogue electrical measuring instruments and their accessories. Part 2: Special requirements for ammeters and voltmeters
IEC 62271-3:2015 High-voltage switchgear and controlgear - Part 3: Digital interfaces based on IEC 61850
IEC 61810-2:2017 Electromechanical elementary relays - Part 2: Reliability
IEC 60064:1993+AMD1:2000+AMD2:2002+AMD3:2005 CSV Tungsten filament lamps for domestic and similar general lighting purposes - Performance requirements
IEC 60296:2012 RLV Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
IEC 60512-2-2:2003 Connectors for electronic equipment - Tests and measurements - Part 2-2: Electrical continuity and contact resistance tests - Test 2b: Contact resistance - Specified test current method
IEC 60721-2-2:2012 Classification of environmental conditions - Part 2-2: Environmental conditions appearing in nature - Precipitation and wind
IEC TR 62063:1999 High-voltage switchgear and controlgear - The use of electronic and associated technologies in auxiliary equipment of switchgear and controlgear
IEC 60447:2004 Basic and safety principles for man-machine interface, marking and identification - Actuating principles
EN 60296:2012 Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
EN 61000-6-2:2005/corrigendum:2005 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005)
IEC TR 62271-307:2015 High-voltage switchgear and controlgear - Part 307: Guidance for the extension of validity of type tests of AC metal and solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60051-5:1985 Direct acting indicating analogue electrical measuring instruments and their accessories. Part 5: Special requirements for phase meters, power factor meters and synchroscopes
IEC 60068-2-17:1994 Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing
IEC TR 60943:1998+AMD1:2008 CSV Guidance concerning the permissible temperature rise for parts of electrical equipment, in particular for terminals
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60947-4-2:2011 Low-voltage switchgear and controlgear - Part 4-2: Contactors and motor-starters - AC semiconductor motor controllers and starters
IEC 60393-1:2008 Potentiometers for use in electronic equipment - Part 1: Generic specification
EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
IEC 60669-1:2017 Switches for household and similar fixed-electrical installations - Part 1: General requirements
IEC 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
IEC 60034-1:2017 Rotating electrical machines - Part 1: Rating and performance
IEC 60255-21-1:1988 Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section One: Vibration tests (sinusoidal)
CISPR TR 18-2:2017 Radio interference characteristics of overhead power lines and high-voltage equipment - Part 2: Methods of measurement and procedure for determining limits
EN 60255-21-1:1995 Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section 1: Vibration tests (sinusoidal)
IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
EN 60071-2:1997 Insulation co-ordination - Part 2: Application guide
IEC 60050-826:2004 International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations
IEC 61180:2016 High-voltage test techniques for low-voltage equipment - Definitions, test and procedure requirements, test equipment
EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
EN 61180:2016 High-voltage test techniques for low-voltage equipment - Definitions, test and procedure requirements, test equipment
IEC 60947-3:2008+AMD1:2012+AMD2:2015 CSV Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units
IEC 60721-2-4:1987+AMD1:1988 CSV Classification of environmental conditions - Part 2-4: Environmental conditions appearing in nature - Solar radiation and temperature
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60059:1999+AMD1:2009 CSV IEC standard current ratings
IEC 60947-2:2016 Low-voltage switchgear and controlgear - Part 2: Circuit-breakers
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC TR 62271-306:2012 High-voltage switchgear and controlgear - Part 306: Guide to IEC 62271-100, IEC 62271-1 and other IEC standards related to alternating current circuit-breakers
EN 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
IEC 61000-4-29:2000 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC 60309-1:1999+AMD1:2005+AMD2:2012 CSV Plugs, socket-outlets and couplers for industrial purposes - Part 1: General requirements
IEC TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles
IEC 60445:2017 Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 60050-581:2008 International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment
IEEE C37.04-1999 IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers
IEC 61000-4-18:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 4-18: Testing and measurement techniques - Damped oscillatory wave immunity test
IEC 60309-2:1999+AMD1:2005+AMD2:2012 CSV Plugs, socket-outlets and couplers for industrial purposes - Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories
IEEE 693-2005 IEEE Recommended Practice for Seismic Design of Substations
IEC TS 60815-3:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 3: Polymer insulators for a.c. systems
EN 61000-4-29:2000 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
EN 62271-4 : 2013 High-voltage switchgear and controlgear - Part 4: Handling procedures for sulphur hexafluoride (SF6) and its mixtures
EN 60038:2011 CENELEC STANDARD VOLTAGES (IEC 60038:2009, MODIFIED)
IEC GUIDE 108:2006 Guidelines for ensuring the coherency of IEC publications - Application of horizontal standards
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.