EN 61810-7:2006
Current
The latest, up-to-date edition.
Electromechanical elementary relays - Part 7: Test and measurement procedures
14-06-2006
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Test and measurement procedures
4.1 General
4.2 Deviations
4.3 Precision of measurement
4.4 Power supplies
4.5 Reference conditions for testing
4.6 Visual inspection and check of dimensions
4.7 Mechanical tests and weighing
4.8 Relay coil properties
4.9 Dielectric strength test
4.10 Impulse voltage test
4.11 Insulation resistance
4.12 Contact-circuit resistance (or voltage drop)
4.13 Functional tests
4.14 Timing tests
4.15 Climatic tests/sequence
4.16 Damp heat, steady state
4.17 Thermal resistance of the coil
4.18 Heating
4.19 Rapid change of temperature
4.20 Enclosure
4.21 Internal moisture
4.22 Corrosive atmospheres
4.23 Mould growth
4.24 Robustness of terminals
4.25 Soldering
4.26 Shock
4.27 Bump
4.28 Vibration
4.29 Acceleration
4.30 Electrical endurance
4.31 Mechanical endurance
4.32 Thermal endurance
4.33 Limiting continuous current
4.34 Overload (contact circuit)
4.35 Load transfer
4.36 Electromagnetic compatibility
4.37 Magnetic interference
4.38 Cross talk and insertion loss
4.39 Electrical contact noise
4.40 Thermoelectric e.m.f
4.41 Capacitance
4.42 Contact sticking (delayed release)
4.43 Magnetic remanence
4.44 Acoustic noise
4.45 Continuity of protective earth connection
4.46 Fluid contamination
4.47 Resistance to cleaning solvents
4.48 Fire hazard
4.49 Temperature rise at rated load
4.50 Mechanical interlock
4.51 Insertion and withdrawal force (mating relay and socket)
Annex A (normative) Heating test arrangement
Annex B (normative) Fire hazard testing
Annex C (normative) Test circuit for endurance tests
Annex D (informative) Inductive contact loads
Annex ZA (normative) Normative references to international
publications with there corresponding European
publications
Bibliography
Lays down the test and measurement procedures for electromechanical elementary relays. Covers basic considerations which are common to all types of electromechanical elementary relays. Supplementary requirements may be necessitated by specific designs or application.
Committee |
CLC/SR 94
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Supersedes |
Standards | Relationship |
UNE-EN 61810-7:2007 | Identical |
IEC 61810-7:2006 | Identical |
CEI EN 61810-7 : 2006 | Identical |
I.S. EN 61810-7:2006 | Identical |
NF EN 61810-7 : 2006 | Identical |
NEN EN IEC 61810-7 : 2006 | Identical |
BS EN 61810-7:2006 | Identical |
DIN EN 61810-7:2007-02 | Identical |
NBN EN 61810-7 : 2006 | Identical |
SN EN 61810-7 : 2006 | Identical |
PN EN 61810-7 : 2008 | Identical |
EN 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
I.S. EN 62271-1:2017 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: COMMON SPECIFICATIONS FOR ALTERNATING CURRENT SWITCHGEAR AND CONTROLGEAR |
BS EN 61810-3:2015 | Electromechanical elementary relays Relays with forcibly guided (mechanically linked) contacts |
BS EN 62271-1:2017 | High-voltage switchgear and controlgear Common specifications for alternating current switchgear and controlgear |
CEI EN 61810-3 : 2016 | ELECTROMECHANICAL ELEMENTARY RELAYS - PART 3: RELAYS WITH FORCIBLY GUIDED (MECHANICALLY LINKED) CONTACTS |
BS EN 80601-2-60:2015 | Medical electrical equipment Particular requirements for the basic safety and essential performance of dental equipment |
I.S. EN 61810-3:2015 | ELECTROMECHANICAL ELEMENTARY RELAYS - PART 3: RELAYS WITH FORCIBLY GUIDED (MECHANICALLY LINKED) CONTACTS |
EN 80601-2-60:2015 | Medical electrical equipment - Part 2-60: Particular requirements for the basic safety and essential performance of dental equipment |
EN 61811-1:2015 | Electromechanical telecom elementary relays of assessed quality - Part 1: Generic specification and blank detail specification |
BS EN 61811-1:2015 | Electromechanical telecom elementary relays of assessed quality Generic specification and blank detail specification |
I.S. EN 61811-1:2015 | ELECTROMECHANICAL TELECOM ELEMENTARY RELAYS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION AND BLANK DETAIL SPECIFICATION |
EN 61810-3:2015 | Electromechanical elementary relays - Part 3: Relays with forcibly guided (mechanically linked) contacts |
IEC 60050-131:2002 | International Electrotechnical Vocabulary (IEV) - Part 131: Circuit theory |
IEC 60068-2-43:2003 | Environmental testing - Part 2-43: Tests - Test Kd: Hydrogen sulphide test for contacts and connections |
IEC 60068-2-68:1994 | Environmental testing - Part 2-68: Tests - Test L: Dust and sand |
EN 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
IEC 60068-2-58:2015+AMD1:2017 CSV | Environmental testing - Part 2-58: Tests - Test Td: Test methods for solderability, resistance to dissolution of metallization and to soldering heat of surface mounting devices (SMD) |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60068-2-13:1983 | Basic environmental testing procedures - Part 2-13: Tests - Test M: Low air pressure |
1989/336/EEC : 1989 | COUNCIL DIRECTIVE OF 3 MAY 1989 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY |
IEC 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 60512-7:1993 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 7: Mechanical operating tests and sealing tests |
IEC 60068-2-11:1981 | Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
IEC 61810-1:2015 | Electromechanical elementary relays - Part 1: General and safety requirements |
EN 60068-2-7:1993 | Environmental testing - Part 2: Tests - Test Ga: Acceleration, steady state |
IEC 60068-2-64:2008 | Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance |
IEC 60695-2-13:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods- Glow-wire ignition temperature (GWIT) test method for materials |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
EN 60695-2-13:2010/A1:2014 | FIRE HAZARD TESTING - PART 2-13: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE IGNITION TEMPERATURE (GWIT) TEST METHOD FOR MATERIALS (IEC 60695-2-13:2010/A1:2014) |
IEC 61810-2:2017 | Electromechanical elementary relays - Part 2: Reliability |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 61180-2:1994 | High-voltage test techniques for low-voltage equipment - Part 2: Test equipment |
IEC 60695-2-12:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials |
EN 61672-1:2013 | Electroacoustics - Sound level meters - Part 1: Specifications |
EN 60068-2-17:1994 | Environmental testing - Part 2: Tests - Test Q: Sealing |
IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
EN 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
IEC 60068-2-10:2005 | Environmental testing - Part 2-10: Tests - Test J and guidance: Mould growth |
EN 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60068-2-68:1996 | Environmental testing - Part 2: Tests - Test L: Dust and sand |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 60068-2-29:1993 | Environmental testing - Part 2: Tests - Test Eb and guidance: Bump |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-13:1999 | Environmental testing - Part 2: Tests - Test M: Low air pressure |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
EN 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
EN 60999-1:2000 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm² up to 35 mm² (included) |
IEC 60068-2-29:1987 | Environmental testing. Part 2: Tests. Test Eb and guidance: Bump |
IEC 60050-444:2002 | International Electrotechnical Vocabulary (IEV) - Part 444: Elementary relays |
EN 60068-2-43:2003 | Environmental testing - Part 2-43: Tests - Test Kd: Hydrogen sulphide test for contacts and connections |
EN 60068-2-11:1999 | Environmental testing - Part 2: Tests - Test Ka: Salt mist |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 61180-1:1992 | High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 60695-11-5:2017 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 60695-11-5:2016 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
EN 60695-2-12:2010/A1:2014 | FIRE HAZARD TESTING - PART 2-12: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY INDEX (GWFI) TEST METHOD FOR MATERIALS (IEC 60695-2-12:2010/A1:2014) |
EN 61180-2:1994 | High-voltage test techniques for low-voltage equipment - Part 2: Test equipment |
EN 60068-2-45:1992/A1:1993 | Environmental testing - Part 2: Tests - Test Xa and guidance: Immersion in cleaning solvents |
EN 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 61180-1:1994 | High-voltage test techniques for low-voltage equipment - Part 1: Definitions, test and procedure requirements |
EN 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014) |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.