INTRODUCTION
1 Scope and object
2 Normative references
3 Terms and definitions
4 Equipment test categories
5 Test waveform and acceleration condition
6 Test setup and parts to be monitored
Annex A (informative) - Example of test setup reporting
Bibliography
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications

IEC 61587-5:2013 specifies seismic test requirements for chassis, subracks, and plug-in units as defined in the IEC 60297 and IEC 60917 series. It applies in whole or in part, only to the mechanical structures of chassis, subracks, and plug-in units for electronic equipment, according to the IEC 60297 and IEC 60917 series, and does not apply to electronic components, equipment or systems within the mechanical structures. The object of this standard is to establish a level of physical integrity of chassis, subracks, and plug-in units according to IEC 60297 and IEC 60917 series that may provide a level of survivability that will preserve functionality during and after a seismic occurrence. It is intended to provide the user with a high level of confidence in the selection of an equipment practice to meet such needs. Since IEC 60297 and IEC 60917 series chassis, subracks, and plug-in units come in many sizes, weights and mechanical complexities, it is not possible to define a single minimum seismic test requirement for all weight categories. Therefore, overall mass categories are defined in this standard. However, the mass distribution inside a chassis and subrack is considered 'application-specific' and herein defined as 'intended use'. Key words: chassis, subracks, plug-in units, seismic tests

Committee
CLC/SR 48D
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

EN 60297-3-109 : 2016 MECHANICAL STRUCTURES FOR ELECTRICAL AND ELECTRONIC EQUIPMENT - DIMENSIONS OF MECHANICAL STRUCTURES OF THE 482,6 MM (19 IN) SERIES - PART 3-109: DIMENSIONS OF CHASSIS FOR EMBEDDED COMPUTING DEVICES
BS EN 60297-3-109:2016 Mechanical structures for electrical and electronic equipment. Dimensions of mechanical structures of the 482,6 mm (19 in) series Dimensions of chassis for embedded computing devices
I.S. EN 60297-3-108:2015 MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - DIMENSIONS OF MECHANICAL STRUCTURES OF THE 482,6 MM (19 IN) SERIES - PART 3-108: DIMENSIONS OF R-TYPE SUBRACKS AND PLUG-IN UNITS (IEC 60297-3-108:2014)
I.S. EN 60297-3-109:2016 MECHANICAL STRUCTURES FOR ELECTRICAL AND ELECTRONIC EQUIPMENT - DIMENSIONS OF MECHANICAL STRUCTURES OF THE 482,6 MM (19 IN) SERIES - PART 3-109: DIMENSIONS OF CHASSIS FOR EMBEDDED COMPUTING DEVICES
CEI EN 61587-1 : 2012 MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 SERIES - PART 1: ENVIRONMENTAL REQUIREMENTS, TEST SET-UP AND SAFETY ASPECTS FOR CABINETS, RACKS, SUBRACKS AND CHASSIS UNDER INDOOR CONDITION USE AND TRANSPORTATION
I.S. EN 61587-1:2017 MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 SERIES - PART 1: ENVIRONMENTAL REQUIREMENTS, TEST SET-UP AND SAFETY ASPECTS FOR CABINETS, RACKS, SUBRACKS AND CHASSIS UNDER INDOOR CONDITION USE AND TRANSPORTATION
EN 60297-3-109:2016 MECHANICAL STRUCTURES FOR ELECTRICAL AND ELECTRONIC EQUIPMENT - DIMENSIONS OF MECHANICAL STRUCTURES OF THE 482,6 MM (19 IN) SERIES - PART 3-109: DIMENSIONS OF CHASSIS FOR EMBEDDED COMPUTING DEVICES
BS EN 60297-3-108:2015 Mechanical structures for electronic equipment. Dimensions of mechanical structures of the 482,6 mm (19 in) series Dimensions of R-type subracks and plug-in units
BS EN 61587-1:2017 Mechanical structures for electronic equipment. Tests for IEC 60917 and IEC 60297 series Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation
EN 61587-1:2017 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 series - Part 1: Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation
EN 60297-3-108:2015 Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-108: Dimensions of R-type subracks and plug-in units

IEC 60297-3-101:2004 Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-101: Subracks and associated plug-in units
ATIS 0600329 : 2014 NETWORK EQUIPMENT - EARTHQUAKE RESISTANCE
EN 60068-2-57:2013 Environmental testing - Part 2-57: Tests - Test Ff: Vibration - Time-history and sine-beat method
HD 478.2.6 : 200S1 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - EARTHQUAKE VIBRATION AND SHOCK
IEC 61587-2:2011 Mechanical structures for electronic equipment - Tests for IEC 60917 and 60297 - Part 2: Seismic tests for cabinets and racks
IEC 61587-3:2013 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 3: Electromagnetic shielding performance tests for cabinets and subracks
IEC 61587-1:2016 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 series - Part 1: Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation
IEC 60068-2-57:2013 Environmental testing - Part 2-57: Tests - Test Ff: Vibration - Time-history and sine-beat method
EN 60297-3-101:2004 Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-101: Subracks and associated plug-in units
EN 61587-1:2017 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 series - Part 1: Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation
IEC 60068-3-3:1991 Environmental testing - Part 3-3: Guidance - Seismic test methods for equipments
EN 60068-3-3:1993 Environmental testing - Part 3: Guidance - Seismic test methods for equipments
EN 61587-3:2013 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 3: Electromagnetic shielding performance tests for cabinets and subracks
IEC 60068-2-47:2005 Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests
IEC 60721-2-6:1990 Classification of environmental conditions. Part 2: Environmental conditions appearing in nature. Earthquake vibration and shock
IEC 60512-2-1:2002 Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
EN 60068-2-47:2005 Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests
EN 60512-2-1:2002 Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more