EN 61514:2002
Current
The latest, up-to-date edition.
Industrial-process control systems - Methods of evaluating the performance of valve positioners with pneumatic outputs
24-04-2002
FOREWORD
1 Scope and object
2 Normative references
3 Definitions
4 General conditions for tests
4.1 Environmental test conditions
4.2 Supply conditions
5 General testing procedures
5.1 Test equipment
5.2 Test methods
5.3 Testing precaution
5.4 Basic test arrangement
5.5 Initial setting-up
6 Test procedures
6.1 Gain characteristic
6.2 Travel characteristic
6.3 Accuracy related terms
6.4 Dead band
6.5 Airflow data
6.6 Effects of influence quantities
6.7 Input over-range
6.8 Drift
6.9 Accelerated life test
6.10 Dynamic response
7 Other considerations
7.1 General
7.2 Safety
7.3 Degree of protection provided by enclosures
7.4 Documentary information
7.5 Installation
7.6 Routine maintenance and adjustment
7.7 Repair
7.8 Protective finishes
7.9 Design features
7.10 Variants
7.11 Tools and equipment
8 Test report and documentation
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
IEC 61514:2000 specifies tests designed to determine the static and dynamic performance of single-acting or double-acting valve positioners. The tests may be applied to positioners which receive standard analogue input signals (as specified in IEC 60381 and IEC 60382) and have a pneumatic output.NOTE For positioners with pulsed or digital input signals, equivalent criteria may be applied. The methods described may not fully apply to positioners with digital controllers or positioners with pulsed outputs.Testing may be conducted either on a positioner alone, independently of an actuator, or on a positioner mounted and connected to a specific actuator, as a combined unit. The text makes clear where different approaches are required. The methods of evaluation given in this standard are intended for use by manufacturers to determine the performance of their products, and by users, or independent testing establishments, to verify manufacturers' performance specifications. This publication is to be read in conjunction with IEC 61514-2:2013.
Committee |
CLC/TC 65X
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
NEN EN IEC 61514 : 2002 | Identical |
NF EN 61514 : 2002 | Identical |
DIN EN 61514:2002-11 | Identical |
UNE-EN 61514:2002 | Identical |
BS EN 61514:2002 | Identical |
PN EN 61514 : 2002 | Identical |
IEC 61514:2000 | Identical |
NBN EN 61514 : 2002 | Identical |
CEI EN 61514 : 2002 | Identical |
BS EN 61514-2:2013 | Industrial process control systems Methods of evaluating the performance of intelligent valve positioners with pneumatic outputs mounted on an actuator valve assembly |
EN 61987-24-1:2016 | Industrial-process measurement and control - Data structures and elements in process equipment catalogues - Part 24-1: Lists of Properties (LOPs) of positioners and I/P converters for electronic data exchange |
EN 61514-2:2013 | INDUSTRIAL PROCESS CONTROL SYSTEMS - PART 2: METHODS OF EVALUATING THE PERFORMANCE OF INTELLIGENT VALVE POSITIONERS WITH PNEUMATIC OUTPUTS MOUNTED ON AN ACTUATOR VALVE ASSEMBLY (IEC 61514-2:2013) |
BS EN 61987-24-1:2016 | Industrial-process measurement and control. Data structures and elements in process equipment catalogues Lists of Properties (LOPs) of positioners and I/P converters for electronic data exchange |
VDI/VDE 3844:2014-01 | Industrial process control valves - Actuators for control valves |
I.S. EN 61514-2:2013 | INDUSTRIAL PROCESS CONTROL SYSTEMS - PART 2: METHODS OF EVALUATING THE PERFORMANCE OF INTELLIGENT VALVE POSITIONERS WITH PNEUMATIC OUTPUTS MOUNTED ON AN ACTUATOR VALVE ASSEMBLY (IEC 61514-2:2013 (EQV)) |
I.S. EN 61987-24-1:2016 | INDUSTRIAL-PROCESS MEASUREMENT AND CONTROL - DATA STRUCTURES AND ELEMENTS IN PROCESS EQUIPMENT CATALOGUES - PART 24-1: LISTS OF PROPERTIES (LOPS) OF POSITIONERS AND I/P CONVERTERS FOR ELECTRONIC DATA EXCHANGE |
IEC 60381-1:1982 | Analogue signals for process control systems. Part 1: Direct current signals |
EN 60382 : 93 AC 94 | ANALOGUE PNEUMATIC SIGNAL FOR PROCESS CONTROL SYSTEMS |
IEC 61187:1993 | Electrical and electronic measuring equipment - Documentation |
EN 61298-4:2008 | Process measurement and control devices - General methods and procedures for evaluating performance - Part 4: Evaluation report content |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
HD 452.1 : 200S1 | ANALOGUE SIGNALS FOR PROCESS CONTROL SYSTEMS - DIRECT CURRENT SIGNALS |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60382:1991 | Analogue pneumatic signal for process control systems |
EN 61000-4-8:2010 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
EN 61032:1998 | Protection of persons and equipment by enclosures - Probes for verification |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
EN 61187:1994/corrigendum:1995 | ELECTRICAL AND ELECTRONIC MEASURING EQUIPMENT - DOCUMENTATION |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 61010-1:2010 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 61032:1997 | Protection of persons and equipment by enclosures - Probes for verification |
IEC 61010-1:2010+AMD1:2016 CSV | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
HD 323.2.56 : 200S1 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - DAMP HEAT, STEADY STATE, PRIMARILY FOR EQUIPMENT |
EN 60068-2-31:2008 | ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS |
IEC 60068-2-56:1988 | Environmental testing - Part 2: Tests. Test Cb: Damp heat, steady state, primarily for equipment |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.