EN 61284:1997
Current
The latest, up-to-date edition.
Overhead lines - Requirements and tests for fittings
21-11-1997
Foreword
Clause
1 Scope
2 Normative references
3 Definitions
4 Requirements
4.1 General requirements
4.1.1 Design
4.1.2 Materials
4.1.3 Dimensions and tolerances
4.1.4 Protection against corrosion
4.1.5 Marking
4.1.6 Instructions for assembly
4.2 Requirements for specific fittings
4.2.1 Insulator set fittings and earth wire fittings
4.2.2 Suspension clamps
4.2.3 Fittings for jointing, terminating and repairing
conductor and earth wire
4.2.4 Insulator protective fittings
5 Heat cycle tests
5.1 Purpose
5.2 Joints
5.2.1 General
5.2.2 Service temperature
5.2.3 Classification for test purposes
5.3 Test specimens
5.3.1 General
5.3.2 Multi-range connectors
5.3.3 Preparation
5.3.4 Data on test specimens
5.4 Test arrangements
5.4.1 Test conditions
5.4.2 Reference conductor
5.4.3 Potential points
5.4.4 Installation of test loop
5.4.5 Measurements
5.5 Heat cycle test procedure
5.5.1 General
5.5.2 Joints of class A
5.5.3 Joints of class B
6 Corona and radio interference voltage (RIV) tests
6.1 Purpose
6.2 Description of test methods
6.3 General
6.4 Test circuit and instruments
6.5 Corona and RIV test procedures
6.6 Acceptance criteria
6.7 Test report
6.8 Voltage method
6.8.1 Adjacent conductors in a three-phase system
6.8.2 Test set-up and dimensions
6.8.3 Critical variant
6.8.4 Distance from wall (reflection plane,) w
6.8.5 Minimum clearance from adjacent live components
6.8.6 Metallic wall
6.9 voltage gradient method
6.9.1 Conductor voltage on three-phase system
6.9.2 Test set-up and dimensions
6.9.3 Test method
Annexes
A Typical joint types
B Typical test circuit - Class A Joints
C Typical test circuit - Class B joints
D Diagrammatic representation of heat cycle test
sequence
E Mathematical acceptance criterion
F Examples of normative documents recommended for
fitting materials
G Potential points
H Test voltage calibration device
ZA Normative references to international publications
with their corresponding European publications
Applies to fittings for overhead lines of nominal voltage above 45 kV. It may also be applied to fittings for overhead lines of lower nominal voltage and to similar fittings for substations.
Committee |
CLC/TC 11
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
I.S. EN 61284:1995 | Identical |
DIN EN 61284 : 1998 | Identical |
CEI EN 61284 : 1999 | Identical |
NEN EN IEC 61284 : 1998 | Identical |
SN EN 61284 : 1997 | Identical |
BS EN 61284:1998 | Identical |
VDE 0212-1 : 1998 | Identical |
UNE-EN 61284:1999 | Identical |
NBN EN 61284 : 1998 | Identical |
NF EN 61284 : 2000 | Similar to |
IEC 61284:1997 | Identical |
PN EN 61284 : 2002 | Identical |
UNE-EN 50341-1:2017 | Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications |
BS EN 50119 : 2009 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
BS EN 50341-2-20:2015 | Overhead electrical lines exceeding AC 45 kV National Normative Aspects (NNA) for ESTONIA (based on EN 50341-1:2012) |
BS EN 50397-1:2006 | Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV a.c. and not exceeding 36 kV a.c Covered conductors |
VDE 0212-2 : 1999 | OVERHEAD LINES - REQUIREMENTS AND TESTS FOR SPACERS |
CEI EN 61897 : 1999 | OVERHEAD LINES - REQUIREMENTS AND TESTS FOR STOCKBRIDGE TYPE AEOLIAN VIBRATION DAMPERS |
PREN 50119 : DRAFT 2017 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
CEI EN 50483-4 : 2011 | TEST REQUIREMENTS FOR LOW VOLTAGE AERIAL BUNDLED CABLE ACCESSORIES - PART 4: CONNECTORS |
CEI EN 50483-2 : 2011 | TEST REQUIREMENTS FOR LOW VOLTAGE AERIAL BUNDLED CABLE ACCESSORIES - PART 2: TENSION AND SUSPENSION CLAMPS FOR SELF SUPPORTING SYSTEM |
BS EN 50341-1:2012 | Overhead electrical lines exceeding AC 1 kV General requirements. Common specifications |
EN 61897:1998 | Overhead lines - Requirements and tests for Stockbridge type aeolian vibration dampers |
VDE 0212-3 : 1999 | OVERHEAD LINES - REQUIREMENTS AND TESTS FOR STOCKBRIDGE TYPE AEOLIAN VIBRATION DAMPERS |
EN 50483-4:2009 | Test requirements for low voltage aerial bundled cable accessories - Part 4: Connectors |
BS EN 50397-2:2009 | Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV AC and not exceeding 36 kV AC Accessories for covered conductors. Tests and acceptance criteria |
BS EN 50483-1:2009 | Test requirements for low voltage aerial bundled cable accessories Generalities |
17/30341013 DC : DRAFT AUG 2017 | BS EN 50119 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
CEI EN 50483-1 : 2011 | TEST REQUIREMENTS FOR LOW VOLTAGE AERIAL BUNDLED CABLE ACCESSORIES - PART 1: GENERALITIES |
I.S. EN 50483-3:2009 | TEST REQUIREMENTS FOR LOW VOLTAGE AERIAL BUNDLED CABLE ACCESSORIES - PART 3: TENSION AND SUSPENSION CLAMPS FOR NEUTRAL MESSENGER SYSTEM |
UNE-EN 50483-3:2013 | Test requirements for low voltage aerial bundled cable accessories -- Part 3: Tension and suspension clamps for neutral messenger system |
CEI EN 61854 : 2000 | OVERHEAD LINES - REQUIREMENTS AND TESTS FOR SPACERS |
NF EN 50397-2 : 2010 | COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV AC AND NOT EXCEEDING 36 KV AC - PART 2: ACCESSORIES FOR COVERED CONDUCTORS - TESTS AND ACCEPTANCE CRITERIA |
I.S. EN 61897:1999 | OVERHEAD LINES - REQUIREMENTS AND TESTS FOR STOCKBRIDGE TYPE AEOLIAN VIBRATION DAMPERS |
EN 50341-2-20:2015 | Overhead electrical lines exceeding AC 1 kV - Part 2-20: National Normative Aspects (NNA) for ESTONIA (based on EN 50341-1:2012) |
EN 50341-1:2012 | Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications |
I.S. EN 50119:2009 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
EN 61854:1998 | Overhead lines - Requirements and tests for spacers |
DIN EN 61897 : 1999 | OVERHEAD LINES - REQUIREMENTS AND TESTS FOR STOCKBRIDGE TYPE AEOLIAN VIBRATION DAMPERS |
EN 50397-1:2006 | Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV a.c. and not exceeding 36 kV a.c. - Part 1: Covered conductors |
03/308257 DC : DRAFT JUNE 2003 | EN 50397-1 - COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV A.C. AND NOT EXCEEDING 37 KV A.C - PART 1: COVERED CONDUCTORS |
DIN EN 61854 : 1999 | OVERHEAD LINES - REQUIREMENTS AND TESTS FOR SPACERS |
CEI EN 50397-1 : 2008 | COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV A.C. AND NOT EXCEEDING 36 KV A.C. - PART 1: COVERED CONDUCTORS |
NF EN 50119 : 2010 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
BS EN 50483-3:2009 | Test requirements for low voltage aerial bundled cable accessories Tension and suspension clamps for neutral messenger system |
I.S. EN 61854:1999 | OVERHEAD LINES - REQUIREMENTS AND TESTS FOR SPACERS |
CEI EN 50341-1 : 2013 | OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
I.S. EN 50341-2-20:2015 | OVERHEAD ELECTRICAL LINES EXCEEDING AC 45 KV - PART 2-20: NATIONAL NORMATIVE ASPECTS (NNA) FOR ESTONIA (BASED ON EN 50341-1:2012) |
12/30260570 DC : 0 | BS EN 50341-1 - OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
UNE-EN 50483-1:2013 | Test requirements for low voltage aerial bundled cable accessories -- Part 1: Generalities |
I.S. EN 50483-1:2009 | TEST REQUIREMENTS FOR LOW VOLTAGE AERIAL BUNDLED CABLE ACCESSORIES - PART 1: GENERALITIES |
I.S. EN 50483-2:2009 | TEST REQUIREMENTS FOR LOW VOLTAGE AERIAL BUNDLED CABLE ACCESSORIES - PART 2: TENSION AND SUSPENSION CLAMPS FOR SELF SUPPORTING SYSTEM |
I.S. EN 50119:2020 | Railway applications - Fixed installations - Electric traction overhead contact lines |
EN 50119 : 2009 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
PREN 50341-1 : DRAFT 2012 | OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
CEI EN 50397-2 : 2011 | COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV AC AND NOT EXCEEDING 36 KV AC - PART 2: ACCESSORIES FOR COVERED CONDUCTORS - TESTS AND ACCEPTANCE CRITERIA |
I.S. EN 50341-1:2012 | OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
UNE-EN 50483-4:2013 | Test requirements for low voltage aerial bundled cable accessories -- Part 4: Connectors |
BS EN 50483-2:2009 | Test requirements for low voltage aerial bundled cable accessories Tension and suspension clamps for self supporting system |
BS EN 50483-4:2009 | Test requirements for low voltage aerial bundled cable accessories Connectors |
CEI EN 50483-3 : 2011 | TEST REQUIREMENTS FOR LOW VOLTAGE AERIAL BUNDLED CABLE ACCESSORIES - PART 3: TENSION AND SUSPENSION CLAMPS FOR NEUTRAL MESSENGER SYSTEM |
I.S. EN 50397-1:2006 | COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV A.C. AND NOT EXCEEDING 36 KV A.C. - PART 1: COVERED CONDUCTORS |
I.S. EN 50397-2:2009 | COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV AC AND NOT EXCEEDING 36 KV AC - PART 2: ACCESSORIES FOR COVERED CONDUCTORS - TESTS AND ACCEPTANCE CRITERIA |
I.S. EN 50483-4:2009 | TEST REQUIREMENTS FOR LOW VOLTAGE AERIAL BUNDLED CABLE ACCESSORIES - PART 4: CONNECTORS |
UNE-EN 50483-2:2013 | Test requirements for low voltage aerial bundled cable accessories -- Part 2: Tension and suspension clamps for self supporting system |
EN 50483-2:2009 | Test requirements for low voltage aerial bundled cable accessories - Part 2: Tension and suspension clamps for self supporting system |
EN 50483-1:2009 | Test requirements for low voltage aerial bundled cable accessories - Part 1: Generalities |
EN 50483-3:2009 | Test requirements for low voltage aerial bundled cable accessories - Part 3: Tension and suspension clamps for neutral messenger system |
EN 50397-2:2009 | Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV AC and not exceeding 36 kV AC - Part 2: Accessories for covered conductors - Tests and acceptance criteria |
DS/EN 50341-2-21:2023 | Overhead electrical lines exceeding AC 1 kV – National Normative Aspects (NNA) for Slovenia (based on EN 50341-1:2012) |
ISO 426-1:1983 | Wrought copper-zinc alloys — Chemical composition and forms of wrought products — Part 1: Non-leaded and special copper-zinc alloys |
ISO 9004-1:1994 | Quality management and quality system elements Part 1: Guidelines |
ISO 209-1:1989 | Wrought aluminium and aluminium alloys Chemical composition and forms of products Part 1: Chemical composition |
IEC 60826:2017 | Design criteria of overhead transmission lines |
ISO 683-13:1974 | Heat-treated steels, alloy steels and free-cutting steels Part 13: Wrought stainless steels |
ISO 6362-2:2014 | Wrought aluminium and aluminium alloys — Extruded rods/bars, tubes and profiles — Part 2: Mechanical properties |
ISO 3951:1989 | Sampling procedures and charts for inspection by variables for percent nonconforming |
ISO 3574:2012 | Cold-reduced carbon steel sheet of commercial and drawing qualities |
ISO 1083:2004 | Spheroidal graphite cast irons - Classification |
ISO 2604-1:1975 | Steel products for pressure purposes Quality requirements Part 1: Forgings |
ISO 426-2:1983 | Wrought copper-zinc alloys — Chemical composition and forms of wrought products — Part 2: Leaded copper-zinc alloys |
ISO 5922:2005 | Malleable cast iron |
ISO 1463:2003 | Metallic and oxide coatings Measurement of coating thickness Microscopical method |
ISO 1461:2009 | Hot dip galvanized coatings on fabricated iron and steel articles — Specifications and test methods |
EN ISO 9002:1994/AC:1997 | QUALITY SYSTEMS - SPECIFICATION FOR PRODUCTION AND INSTALLATION |
ISO 2859-2:1985 | Sampling procedures for inspection by attributes — Part 2: Sampling plans indexed by limiting quality (LQ) for isolated lot inspection |
HD 588.1 : S1 AMD 1 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS |
EN ISO 9003:1994/AC:1997 | QUALITY SYSTEMS - SPECIFICATION FOR FINAL INSPECTION AND TEST |
ISO 9002:1994 | Quality systems — Model for quality assurance in production, installation and servicing |
ISO 1187:1983 | Special wrought copper alloys — Chemical composition and forms of wrought products |
ISO 3506:1979 | Corrosion-resistant stainless steel fasteners — Specifications |
EN ISO 9000-1 : 1994 | QUALITY MANAGEMENT AND QUALITY ASSURANCE STANDARDS - PART 1: GUIDELINES FOR SELECTION AND USE (ISO 9000-1:1994) |
HD 474 : 200S1 | DIMENSIONS OF BALL AND SOCKET COUPLINGS OF STRING INSULATOR UNITS |
IEC 60437:1997 | Radio interference test on high-voltage insulators |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN ISO 9004-1 : 1994 | QUALITY SYSTEMS - PRINCIPAL CONCEPTS AND APPLICATIONS - GUIDE TO QUALITY MANAGEMENT AND QUALITY SYSTEM ELEMENTS |
ISO 1459:1973 | Metallic coatings — Protection against corrosion by hot dip galvanizing — Guiding principles |
IEC 60050-466:1990 | International Electrotechnical Vocabulary (IEV) - Part 466: Overhead lines |
ISO 6361-2:2014 | Wrought aluminium and aluminium alloys Sheets, strips and plates Part 2: Mechanical properties |
IEC 60372:1984 | Locking devices for ball and socket couplings of string insulator units - Dimensions and tests |
ISO 9001:2015 | Quality management systems — Requirements |
ISO 427:1983 | Wrought copper-tin alloys Chemical composition and forms of wrought products |
ISO 6932:2014 | Cold-reduced carbon steel strip with a maximum carbon content of 0,25 % |
ISO 9003:1994 | Quality systems Model for quality assurance in final inspection and test |
ISO 630:1995 | Structural steels Plates, wide flats, bars, sections and profiles |
ISO 1460:1992 | Metallic coatings Hot dip galvanized coatings on ferrous materials Gravimetric determination of the mass per unit area |
ISO 1336:1980 | Wrought coppers (having minimum copper contents of 97,5 %) Chemical composition and forms of wrought products |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60120:1984 | Dimensions of ball and socket couplings of string insulator units |
ISO 3522:2007 | Aluminium and aluminium alloys — Castings — Chemical composition and mechanical properties |
ISO 3755:1991 | Cast carbon steels for general engineering purposes |
CISPR 16-1:1999+AMD1:2002 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus |
ISO 683-1:2016 | Heat-treatable steels, alloy steels and free-cutting steels Part 1: Non-alloy steels for quenching and tempering |
ISO 6363-2:2012 | Wrought aluminium and aluminium alloys — Cold-drawn rods/bars and tubes and wires — Part 2: Mechanical properties |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.