EN 61260-1:2014
Current
The latest, up-to-date edition.
Electroacoustics - Octave-band and fractional-octave-band filters - Part 1: Specifications
20-06-2014
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Reference environmental conditions
5 Performance requirements
6 Instrument marking
7 Instruction manual
Annex A (informative) - Relationship between tolerance
interval, corresponding acceptance interval and
the maximum-permitted uncertainty of measurement
Annex B (normative) - Maximum-permitted expanded
uncertainties of measurement
Annex C (informative) - Examples of conformance
assessment to specifications of this standard
Annex D (informative) - Base 2 filters
Annex E (normative) - Nominal mid-band frequencies
Annex F (informative) - Normalized frequencies at
breakpoints of acceptance limits on minimum
and maximum relative attenuation for
one-third-octave-band filters
Annex G (informative) - Filter response to exponentially
swept sinusoidal signals
Annex H (informative) - Measurement of filter decay time
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
IEC 61260-1:2014 specifies performance requirements for analogue, sampled-data, and digital implementations of band-pass filters. The extent of the pass-band region of a filter's relative attenuation characteristic is a constant percentage of the exact mid-band frequency for all filters of a given bandwidth. An instrument conforming to the requirements of this standard may contain any number of contiguous band-pass filters covering any desired frequency range. Performance requirements are provided for two filter classes: class 1 and class 2. In general, specifications for class 1 and class 2 filters have the same design goals and differ mainly in the acceptance limits and the range of operational temperature. Acceptance limits for class 2 are greater than, or equal to, those for class 1. Maximum-permitted expanded uncertainties of measurement are also specified. Band-pass filters conforming to the performance requirements of this standard may be part of various measurement systems or may be an integral component of a specific instrument such as a spectrum analyser. This standard specifies the ranges of environmental conditions for operation of the filters. The required range depends on whether the instrument containing the filters is designed to be operated in a controlled environment or more generally in the field. Band-pass filters conforming to the requirements of this standard are capable of providing frequency-band-filtered spectral information for a wide variety of signals, for example, time-varying, intermittent or steady; broadband or discrete frequency; and long or short durations. This first edition of IEC 61260-1, future IEC 61260-2 and future IEC 61260-3, cancel and replace the first edition of IEC 61260 (1995) and its amendment 1 (2001). This edition constitutes a technical revision which includes the following significant technical changes with respect to the IEC 61260 (1995) and its amendment 1 (2001): - the single document in the first edition of IEC 61260 (1995) and its amendment 1 (2001) is in IEC 61260 series separated into the three parts covering: specifications, pattern evaluation tests and periodic tests; - the performance category class 0 is removed; - the design goals for the specification can be based only base-10; - the reference environmental conditions have been changed from 20 °C / 65 % RH to 23 °C / 50 % RH; and - IEC 61260 (1995) specified tolerance limits without considering the uncertainty of measurement for verification of the specifications. IEC 61260 series specifies acceptance limits for the observed values and maximum-permitted uncertainty of measurements for laboratories testing conformance to specifications in the standard.
Committee |
CLC/SR 29
|
DevelopmentNote |
Supersedes EN 61260. (07/2014)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Supersedes |
Standards | Relationship |
CEI EN 61260-1 : 2017 | Identical |
NEN EN IEC 61260-1 : 2014 | Identical |
BS EN 61260-1:2014 | Identical |
DIN EN 61260-1:2014-10 | Identical |
NF EN 61260-1 : 2014 | Identical |
NBN EN 61260-1 : 2014 | Identical |
I.S. EN 61260-1:2014 | Identical |
PN EN 61260-1 : 2015 | Identical |
SN EN 61260-1:2014 | Identical |
IEC 61260-1:2014 | Identical |
UNE-EN 61260-1:2014 | Identical |
UNE-EN 61260-1 | Identical |
PNE-FprEN 61260-1 | Identical |
PREN 15610 : DRAFT 2017 | RAILWAY APPLICATIONS - ACOUSTICS - RAIL AND WHEEL ROUGHNESS MEASUREMENT RELATED TO ROLLING NOISE GENERATION |
EN 61669:2016 | Electroacoustics - Measurement of real-ear acoustical performance characteristics of hearing aids |
BS EN 61260-2 : 2016 | ELECTROACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS - PART 2: PATTERN-EVALUATION TESTS |
S.R. CEN/TR 16891:2016 | RAILWAY APPLICATIONS - ACOUSTICS - MEASUREMENT METHOD FOR COMBINED ROUGHNESS, TRACK DECAY RATES AND TRANSFER FUNCTIONS |
VDI 2057-1 : 2017 COR 1 2017 | HUMAN EXPOSURE TO MECHANICAL VIBRATIONS - WHOLE-BODY VIBRATION |
CEI EN 61260-2 : 2017 | ELECTROACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS - PART 2: PATTERN-EVALUATION TESTS |
BS EN 61260-3:2016 | Electroacoustics. Octave-band and fractional-octave-band filters Periodic tests |
I.S. EN 61260-3:2016 | ELECTROACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS - PART 3: PERIODIC TESTS |
I.S. EN 60645-1:2017 | ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY |
BS EN 60268-4:2014 | Sound system equipment Microphones |
BS EN 60645-1:2017 | Electroacoustics. Audiometric equipment Equipment for pure-tone and speech audiometry |
CEI EN 61260-3 : 2017 | ELECTROACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS - PART 3: PERIODIC TESTS |
EN 61260-2:2016/A1:2017 | ELECTROACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS - PART 2: PATTERN-EVALUATION TESTS (IEC 61260-2:2016/A1:2017) |
PD CEN/TR 16891:2016 | Railway applications. Acoustics. Measurement method for combined roughness, track decay rates and transfer functions |
I.S. EN 61669:2016 | ELECTROACOUSTICS - MEASUREMENT OF REAL-EAR ACOUSTICAL PERFORMANCE CHARACTERISTICS OF HEARING AIDS |
I.S. EN 61260-2:2016 | ELECTROACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS - PART 2: PATTERN-EVALUATION TESTS |
17/30304301 DC : 0 | BS EN 15610 - RAILWAY APPLICATIONS - ACOUSTICS - RAIL AND WHEEL ROUGHNESS MEASUREMENT RELATED TO ROLLING NOISE GENERATION |
I.S. EN 60268-4:2014 | SOUND SYSTEM EQUIPMENT - PART 4: MICROPHONES |
EN 61260-3:2016 | Electroacoustics - Octave-band and fractional-octave-band filters - Part 3: Periodic tests |
CEN/TR 16891:2016 | Railway applications - Acoustics - Measurement method for combined roughness, track decay rates and transfer functions |
EN 60268-4:2014 | Sound system equipment - Part 4: Microphones |
EN 60645-1:2017 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry |
EN 61000-6-1:2007 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments |
EN 61000-6-3:2007/A1:2011/AC:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010) |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
ISO/IEC Guide 98-4:2012 | Uncertainty of measurement Part 4: Role of measurement uncertainty in conformity assessment |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
IEC 61000-6-3:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
EN 61672-1:2013 | Electroacoustics - Sound level meters - Part 1: Specifications |
EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
EN 61000-6-2:2005/corrigendum:2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005) |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 61000-6-1:2016 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.