EN 61223-2-5:1994
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Evaluation and routine testing in medical imaging departments - Part 2-5: Constancy tests - Image display devices
01-03-2000
09-06-1994
Introduction
1. Scope and object
1.1 Scope
1.2 Object
2. Normative references
3. Terminology
3.1 Degree of requirements
3.2 Use of terms
3.3 Definitions
4. General aspects of CONSTANCY TESTS
4.1 General conditions affecting test procedures
4.2 Establishment of BASELINE VALUES
4.3 Frequency of CONSTANCY TESTS
4.4 Identification of equipment, instrumentation and
test conditions
4.5 Measured functional parameters
5. Test methods
5.1 Summary
5.2 Test equipment
5.3 Test procedure
5.4 Data evaluation
5.5 Criteria to be applied
5.6 Test report
5.7 Action to be taken
5.8 Frequency of testing
6. Statement of compliance
Figures
1. Schematic representation of a test pattern used to
check the constancy with respect to grey-scale
reproduction
2. Schematic representation of a test pattern used to
check the constancy with respect to geometry and
line structure
3. Schematic representation of a crosshatched pattern
used to carry out measurements with respect to
geometry
4. Schematic representation of a test pattern used to
check the constancy with respect to resolution
5. Schematic representation of a test pattern used to
check the constancy with respect to colour-related
aspects
6. Preventive measures to establish optimal working
conditions in workstations
Annexes
A. Terminology - Index of terms
B. Example of a form for the standardized test report
C. Guidance on action to be taken
D. Rationale
E. Bibliography - Reference test pattern
F. IMAGE DISPLAY DEVICES in workstations: Environmental
conditions
Annex ZA (normative) Other international publications
quoted in this standard with the references of the
relevant European publications
Applies to image display devices as used in diagnostic imaging systems. Describes a method to check, in terms of functional parameters the constancy of the quality of images reproduced by image display devices.
Committee |
CLC/TC 62
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
Standards | Relationship |
DIN EN 61223-2-5:2004-09 | Identical |
NF EN 61223-2-5 : 1994 | Identical |
IEC 61223-2-5:1994 | Identical |
NBN EN 61223 2-5 : 1995 | Identical |
NEN 11223-2-5 : 1994 | Identical |
I.S. EN 61223-2-5:1994 | Identical |
PN EN 61223-2-5 : 2002 | Identical |
SN EN 61223-2-5 : 1994 | Identical |
BS EN 61223-2-5:1995 | Identical |
BS 7725-2.5(1995) : 1995 | Identical |
UNE-EN 61223-2-5:1996 | Identical |
CEI EN 61223-2-5 : 1998 | Identical |
UNE-EN 61223-2-5:1994 | Identical |
BS EN 62563-1:2010 | Medical electrical equipment. Medical image display systems Evaluation methods |
EN 62563-1:2010/A1:2016 | MEDICAL ELECTRICAL EQUIPMENT - MEDICAL IMAGE DISPLAY SYSTEMS - PART 1: EVALUATION METHODS (IEC 62563-1:2009/A1:2016) |
IEC TR 60788:2004 | Medical electrical equipment - Glossary of defined terms |
IEC 61223-2-4:1994 | Evaluation and routine testing in medical imaging departments - Part 2-4: Constancy tests - Hard copy cameras |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.