EN 61166:1993
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
High-voltage alternating current circuit-breakers - Guide for seismic qualification of high-voltage alternating current circuit-breakers
23-07-2013
23-07-1993
Cooperating organizations
National foreword
Foreword
1 Scope and object
2 Normative references
3 Definitions
4 Seismic qualification requirements
5 Severities
6 Qualification by test
6.1 Introduction
6.2 Mounting
6.3 External load
6.4 Measurement
6.5 Frequency range
6.6 Test severity
6.6.1 Parameters for sine-beat excitation
6.6.2 Parameters for time-history excitation
6.7 Testing
6.7.1 Test directions
6.7.2 Test sequence
7 Qualification by combined test and analysis
7.1 Introduction
7.2 Vibrational and functional data
7.3 Analysis
7.3.1 Acceleration time-history method of calculation
7.3.2 Modal analysis using the required response
spectrum (RRS)
7.3.3 Static coefficient analysis
8 Evaluation of the seismic qualification
8.1 Combination of stresses
8.2 Acceptance criteria of the seismic simulation
8.3 Functional evaluation of the test results
9 Documentation
9.1 Information for seismic qualification
9.2 Test report
9.3 Analysis report
Figures
Annexes
A Characterization of the equipment
ZA (normative) Other international publications
quoted in this standard with the references of
the relevant European publications
National annex NA (informative) Committees responsible
National annex NB (informative) Cross-references
Specifies seismic severity levels and gives a choice of methods that can be applied to demonstrate the performance of HV circuit-breakers for which seismic qualification is required.
Committee |
CLC/TC 17AC
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
Standards | Relationship |
NEN 11166 : 1994 | Identical |
PN EN 61166 : 2002 | Identical |
VDE 0670-111 : 1994 | Identical |
NBN EN 61166 : 1995 | Identical |
BS EN 61166:1993 | Identical |
UNE-EN 61166:1997 | Identical |
NF EN 61166 : 1993 | Identical |
SN EN 61166 : 1993 | Identical |
IEC 61166:1993 | Identical |
I.S. EN 61166:1996 | Identical |
DIN EN 61166 : 1994 | Identical |
CEI EN 61166 : 2013 | Identical |
DIN EN 45510-2-7:2003-12 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
I.S. EN 60044-8:2002 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
BS EN 60044-8:2002 | Instrument transformers Electronic current transformers |
I.S. EN 60694:1999 | COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS |
EN 62155:2003 | Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V |
EN 60694:1996/A2:2001 | COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS |
BS EN 45510-2-7:2002 | Guide for the procurement of power station equipment. Electrical equipment Switchgear and controlgear |
94/712993 DC : DRAFT NOV 1994 | PREN 45511 - GUIDE FOR PROCUREMENT - ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
CEI EN 62155 : 2004 | HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V |
CEI UNI EN 45510-2-7 : 2006 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
I.S. EN 45510-2-7:2002 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
BS EN 60694:1997 | Common specifications for high-voltage switchgear and controlgear standards |
CEI EN 60044-8 : 2004 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRASFORMERS |
UNI CEI EN 45510-2-7 : 2011 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
BS EN 61264:1999 | Ceramic pressurized hollow insulators for high-voltage switchgear and controlgear |
I.S. EN 62155:2003 | HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V |
EN 45510-2-7:2002 | Guide for procurement of power station equipment - Part 2-7: Electrical equipment - Switchgear and controlgear |
BS EN 62155:2003 | Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1000 V |
EN 60044-8:2002 | Instrument transformers - Part 8: Electronic current transformers |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.