Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 61166:1993

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

High-voltage alternating current circuit-breakers - Guide for seismic qualification of high-voltage alternating current circuit-breakers

Withdrawn date

23-07-2013

Published date

23-07-1993

Sorry this product is not available in your region.

Cooperating organizations
National foreword
Foreword
1 Scope and object
2 Normative references
3 Definitions
4 Seismic qualification requirements
5 Severities
6 Qualification by test
6.1 Introduction
6.2 Mounting
6.3 External load
6.4 Measurement
6.5 Frequency range
6.6 Test severity
6.6.1 Parameters for sine-beat excitation
6.6.2 Parameters for time-history excitation
6.7 Testing
6.7.1 Test directions
6.7.2 Test sequence
7 Qualification by combined test and analysis
7.1 Introduction
7.2 Vibrational and functional data
7.3 Analysis
7.3.1 Acceleration time-history method of calculation
7.3.2 Modal analysis using the required response
       spectrum (RRS)
7.3.3 Static coefficient analysis
8 Evaluation of the seismic qualification
8.1 Combination of stresses
8.2 Acceptance criteria of the seismic simulation
8.3 Functional evaluation of the test results
9 Documentation
9.1 Information for seismic qualification
9.2 Test report
9.3 Analysis report
Figures
Annexes
A Characterization of the equipment
ZA (normative) Other international publications
       quoted in this standard with the references of
       the relevant European publications
National annex NA (informative) Committees responsible
National annex NB (informative) Cross-references

Specifies seismic severity levels and gives a choice of methods that can be applied to demonstrate the performance of HV circuit-breakers for which seismic qualification is required.

Committee
CLC/TC 17AC
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Withdrawn

Standards Relationship
NEN 11166 : 1994 Identical
PN EN 61166 : 2002 Identical
VDE 0670-111 : 1994 Identical
NBN EN 61166 : 1995 Identical
BS EN 61166:1993 Identical
UNE-EN 61166:1997 Identical
NF EN 61166 : 1993 Identical
SN EN 61166 : 1993 Identical
IEC 61166:1993 Identical
I.S. EN 61166:1996 Identical
DIN EN 61166 : 1994 Identical
CEI EN 61166 : 2013 Identical

DIN EN 45510-2-7:2003-12 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
I.S. EN 60044-8:2002 INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS
BS EN 60044-8:2002 Instrument transformers Electronic current transformers
I.S. EN 60694:1999 COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
EN 62155:2003 Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V
EN 60694:1996/A2:2001 COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
BS EN 45510-2-7:2002 Guide for the procurement of power station equipment. Electrical equipment Switchgear and controlgear
94/712993 DC : DRAFT NOV 1994 PREN 45511 - GUIDE FOR PROCUREMENT - ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
CEI EN 62155 : 2004 HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V
CEI UNI EN 45510-2-7 : 2006 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
I.S. EN 45510-2-7:2002 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
BS EN 60694:1997 Common specifications for high-voltage switchgear and controlgear standards
CEI EN 60044-8 : 2004 INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRASFORMERS
UNI CEI EN 45510-2-7 : 2011 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
BS EN 61264:1999 Ceramic pressurized hollow insulators for high-voltage switchgear and controlgear
I.S. EN 62155:2003 HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V
EN 45510-2-7:2002 Guide for procurement of power station equipment - Part 2-7: Electrical equipment - Switchgear and controlgear
BS EN 62155:2003 Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1000 V
EN 60044-8:2002 Instrument transformers - Part 8: Electronic current transformers

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more