EN 61000-4-25 : 2002 AMD 1 2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-25: TESTING AND MEASUREMENT TECHNIQUES - HEMP IMMUNITY TEST METHODS FOR EQUIPMENT AND SYSTEMS (IEC 61000-4-25:2001/A1:2012)
08-04-2020
12-01-2013
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 General
5 Immunity tests and immunity test levels
6 Test equipment
7 Test set-up
8 Test procedure
9 Test results and test reports
Annex A (informative) - Rationale for the immunity test
levels
Annex B (informative) - Conducted immunity tests for
antennas
Annex C (informative) - Conducted disturbance immunity
Tests
Annex D (informative) - Damped oscillatory wave test
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Covers the immunity test levels and related test methods for electrical and electronic equipment and systems exposed to high-altitude electromagnetic pulse (HEMP) environments.
Committee |
TC 210
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
CEI EN 61000-4-25/A1:2013 | Identical |
OVE/ONORM EN 61000-4-25 : 2013 | Identical |
NF EN 61000-4-25 : 2002 AMD 1 2013 | Identical |
UNE-EN 61000-4-25:2003 | Identical |
IEC 61000-4-25:2001+AMD1:2012 CSV | Identical |
NEN EN IEC 61000-4-25 : 2004 AMD 1 2012 | Identical |
I.S. EN 61000-4-25:2002 | Identical |
PN EN 61000-4-25 : 2003 AMD 1 2012 | Identical |
VDE 0847-4-25 : 2013 | Identical |
DIN EN 61000-4-25 : 2013 | Identical |
BS EN 61000-4-25 : 2002 | Identical |
I.S. EN 61000-4-25:2002/A2:2020 | Identical |
NBN EN 61000 4-25 : 2003 AMD 1 2012 | Identical |
BS EN 61000-4-1:2007 | Electromagnetic compatibility (EMC) Testing and measurement techniques. Overview of IEC 61000-4 series |
BS EN 61000-4-18 : 2007 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-18: TESTING AND MEASUREMENT TECHNIQUES - DAMPED OSCILLATORY WAVE IMMUNITY TEST |
I.S. EN 61000-4-1:2007 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-1: TESTING AND MEASUREMENT TECHNIQUES - OVERVIEW OF IEC 61000-4 SERIES |
EN 61000-4-1:2007 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
IEC TR 61000-5-3:1999 | Electromagnetic compatibility (EMC) - Part 5-3: Installation and mitigation guidelines - HEMP protection concepts |
IEC 60038:2009 | IEC standard voltages |
VG 96903-78 : 2011 | NUCLEAR ELECTROMAGNETIC PULSE (NEMP) AND LIGHTNING PROTECTION - TEST METHODS, TEST EQUIPMENT AND LIMITING VALUES - PART 78: DIRECT INJECTION OF NEMP DISTURBING QUANTITIES TO CABLES AND CABLE HARNESSES OF MULTI-APPLICATION EQUIPMENT (TEST METHOD LF 78) |
IEC 61024-1:1990 | Protection of structures against lightning - Part 1: General principles |
IEC 61000-2-10:1998 | Electromagnetic compatibility (EMC) - Part 2-10: Environment - Description of HEMP environment - Conducted disturbance |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 61000-2-10:1999 | Electromagnetic compatibility (EMC) - Part 2-10: Environment - Description of HEMP environment - Conducted disturbance |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
IEC 61000-2-11:1999 | Electromagnetic compatibility (EMC) - Part 2-11: Environment - Classification of HEMP environments |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 61000-2-9:1996 | Electromagnetic compatibility (EMC) - Part 2: Environment - Section 9: Description of HEMP environment - Radiated disturbance |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 61000-4-33:2005 | Electromagnetic compatibility (EMC) - Part 4-33: Testing and measurement techniques - Measurement methods for high-power transient parameters |
MIL-STD-461 Revision G:2015 | REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT |
IEC 61000-4-20:2010 | Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides |
VG 96903-70 : 2011 | NUCLEAR ELECTROMAGNETIC PULSE (NEMP) AND LIGHTNING PROTECTION - TEST METHODS, TEST EQUIPMENT AND LIMITING VALUES - PART 70: DIRECT INJECTION OF NEMP DISTURBING QUANTITIES INTO LINE TERMINALS OF MULTI-APPLICATION EQUIPMENT (TEST METHOD LF 70) |
ISO 7137:1995 | Aircraft — Environmental conditions and test procedures for airborne equipment |
IEC 61000-2-9:1996 | Electromagnetic compatibility (EMC) - Part 2: Environment - Section 9: Description of HEMP environment - Radiated disturbance. Basic EMC publication |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
EN 61000-4-13:2002/A2:2016 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-13: TESTING AND MEASUREMENT TECHNIQUES - HARMONICS AND INTERHARMONICS INCLUDING MAINS SIGNALLING AT A.C. POWER PORT, LOW FREQUENCY IMMUNITY TESTS (IEC 61000-4-13:2002/A2:2015) |
IEC 61000-4-18:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-18: Testing and measurement techniques - Damped oscillatory wave immunity test |
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV | Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests |
EN 61000-4-20:2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-20: TESTING AND MEASUREMENT TECHNIQUES - EMISSION AND IMMUNITY TESTING IN TRANSVERSE ELECTROMAGNETIC (TEM) WAVEGUIDES |
EN 60038:2011 | CENELEC STANDARD VOLTAGES (IEC 60038:2009, MODIFIED) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.