Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 61000-2-4:2002/AC:2014

Current

Current

The latest, up-to-date edition.

ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-4: ENVIRONMENT - COMPATIBILITY LEVELS IN INDUSTRIAL PLANTS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES

Published date

10-07-2014

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 Electromagnetic environment classes
5 Compatibility levels
6 Compatibility levels
Annex A (informative) - Explanations and examples for
        interharmonics
Annex B (informative) - Examples of expected disturbance levels
        in typical industrial networks
Annex C (informative) - Interharmonic and voltages at higher
        frequencies
Bibliography
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications

Deals with conducted disturbances in the frequency range from 0 kHz to 9 kHz. Also provides numerical compatibility levels for industrial and non-public power distribution systems at nominal voltages up to 35 kV and a nominal frequency of 50 Hz or 60 Hz.

Committee
TC 210
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

CEI EN 62586-2 : 2015 POWER QUALITY MEASUREMENT IN POWER SUPPLY SYSTEMS - PART 2: FUNCTIONAL TESTS AND UNCERTAINTY REQUIREMENTS
EN 61000-4-30:2015/AC:2017-01 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS (IEC 61000-4-30:2015/COR1:2016)
14/30297515 DC : 0 BS EN 16704-2-1 - RAILWAY APPLICATIONS - TRACK - SAFETY PROTECTION ON THE TRACK DURING WORK - PART 2-1: COMMON SOLUTIONS AND TECHNOLOGY - TECHNICAL REQUIREMENTS FOR TRACK WARNING SYSTEMS (TWS)
CLC/TS 50217:2005 Guide for in situ measurements - In situ measurement of disturbance emission
BS EN 50240:2004 Electromagnetic compatibilty (EMC). Product standard for resistance welding equipment
DD CLC/TS 50217:2005 Guide for in situ measurements. In situ measurement of disturbance emission
BS EN 61800-5-2:2017 Adjustable speed electrical power drive systems Safety requirements. Functional
09/30214359 DC : 0 BS EN 50533 - RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
I.S. EN 50125-3:2003 RAILWAY APPLICATION - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 3: EQUIPMENT FOR SIGNALLING AND TELECOMMUNICATIONS
UNE-EN 61000-4-30:2015 Electromagnetic compatibility (EMC) - Part 4-30: Testing and measurement techniques - Power quality measurement methods
BS EN 61000-4-27 : 2001 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-27: TESTING AND MEASUREMENT TECHNIQUES - UNBALANCE, IMMUNITY TEST FOR EQUIPMENT WITH INPUT CURRENT NOT EXCEEDING 16 A PER PHASE
CEI EN 50328 : 2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRONIC POWER CONVERTERS FOR SUBSTATIONS
BS EN 50533 : 2011 RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
PD CLC/TR 50646:2015 Railway Application. Fixed Installations. Specification for reversible d.c. substations
CEI EN 60146-2 : 2001 SEMICONDUCTOR CONVERTERS - PART 2: SELF-COMMUTATED SEMICONDUCTOR CONVERTERS INCLUDING DIRECT D.C. CONVERTERS
CEI EN 61000-3-12 : 2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-12: LIMITS - LIMITS FOR HARMONIC CURRENTS PRODUCED BY EQUIPMENT CONNECTED TO PUBLIC LOW-VOLTAGE SYSTEMS WITH INPUT CURRENT > 16 A AND <= 75 A PER PHASE
I.S. EN 61000-4-30:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS
I.S. EN 50328:2007 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRONIC POWER CONVERTERS FOR SUBSTATIONS
EN 61000-4-8:2010 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
EN 61000-4-13:2002/A2:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-13: TESTING AND MEASUREMENT TECHNIQUES - HARMONICS AND INTERHARMONICS INCLUDING MAINS SIGNALLING AT A.C. POWER PORT, LOW FREQUENCY IMMUNITY TESTS (IEC 61000-4-13:2002/A2:2015)
EN 61000-3-12:2011 Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and
EN 50125-3 : 2003 COR 2010 RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 3: EQUIPMENT FOR SIGNALLING AND TELECOMMUNICATIONS
EN 61136-1 : 1995 SEMICONDUCTOR POWER CONVECTORS - ADJUSTABLE SPEED ELECTRIC DRIVE SYSTEMS - GENERAL REQUIREMENTS - RATING SPECIFICATIONS, PARTICULARLY FOR D.C. MOTOR DRIVES
EN 61000-4-27:2000/A1:2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-27: TESTING AND MEASUREMENT TECHNIQUES - UNBALANCE, IMMUNITY TEST FOR EQUIPMENT WITH INPUT CURRENT NOT EXCEEDING 16 A PER PHASE
UNE-EN 62586-2:2014 Power quality measurement in power supply systems - Part 2: Functional tests and uncertainty requirements
EN 61000-2-12:2003 Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems
EN 61800-5-2:2017 Adjustable speed electrical power drive systems - Part 5-2: Safety requirements - Functional
03/111744 DC : DRAFT JULY 2003
CEI EN 62274 : 2005 MEDICAL ELECTRICAL EQUIPMENT - SAFETY OF RADIOTHERAPY RECORD AND VERIFY SYSTEMS
UNE-EN 61000-3-12:2012 Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and
I.S. EN 61000-4-14:1999 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-14: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE FLUCTUATION IMMUNITY TEST FOR EQUIPMENT WITH INPUT CURRENT NOT EXCEEDING 16 A PER PHASE
UNE EN 62586-2 : 2014 POWER QUALITY MEASUREMENT IN POWER SUPPLY SYSTEMS - PART 2: FUNCTIONAL TESTS AND UNCERTAINTY REQUIREMENTS
I.S. EN 16704-2-1:2016 RAILWAY APPLICATIONS - TRACK - SAFETY PROTECTION ON THE TRACK DURING WORK - PART 2-1: COMMON SOLUTIONS AND TECHNOLOGIES - TECHNICAL REQUIREMENTS FOR TRACK WARNING SYSTEMS (TWS)
I.S. EN 61000-4-27:2000 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-27: TESTING AND MEASUREMENT TECHNIQUES - UNBALANCE, IMMUNITY TEST FOR EQUIPMENT WITH INPUT CURRENT NOT EXCEEDING 16 A PER PHASE
BS EN 50600-2-2:2014 Information technology. Data centre facilities and infrastructures Power distribution
I.S. EN 60146-1-1:2010 SEMICONDUCTOR CONVERTERS - GENERAL REQUIREMENTS AND LINE COMMUTATED CONVERTERS - PART 1-1: SPECIFICATION OF BASIC REQUIREMENTS
I.S. EN 809:1998 PUMPS AND PUMP UNITS FOR LIQUIDS - COMMON SAFETY REQUIREMENTS
DIN EN 61800-1 : 1999-08 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 1: GENERAL REQUIREMENTS; RATING SPECIFICATIONS FOR LOW VOLTAGE ADJUSTABLE SPEED D.C. POWER DRIVE SYSTEMS
VDE 0160-101 : 1999-08 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - GENERAL REQUIREMENTS - RATING SPECIFICATIONS FOR LOW VOLTAGE ADJUSTABLE SPEED D.C. POWER DRIVE SYSTEMS
CEI EN 61800-1 : 2000 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 1: GENERAL REQUIREMENTS - RATING SPECIFICATIONS FOR LOW VOLTAGE ADJUSTABLE SPEED D.C. POWER DRIVE SYSTEMS
DIN EN 60146-2 : 2001 SEMICONDUCTOR CONVERTORS - PART 2: SELF-COMMUTATED SEMICONDUCTOR CONVERTORS INCLUDING DIRECT D.C. CONVERTORS
VDE 0558-2 : 2001 SEMICONDUCTOR CONVERTORS - PART 2: SELF-COMMUTATED SEMICONDUCTOR CONVERTORS INCLUDING DIRECT D.C. CONVERTORS
VDI 3551:2011-01 Electromagnetic compatibility (EMC) in building services
I.S. EN 61800-3:2005 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS (IEC 61800-3:2004 (EQV))
I.S. EN 50600-2-2:2014 INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-2: POWER DISTRIBUTION
BS EN 61000-4-28 : 2000 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-28: TESTING AND MEASUREMENT TECHNIQUES - VARIATION OF POWER FREQUENCY, IMMUNITY TEST FOR EQUIPMENT WITH INPUT CURRENT NOT EXCEEDING 16 A PER PHASE
BS EN 61800-3 : 2004 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS
BS EN 61000-4-30:2015 Electromagnetic compatibility (EMC) Testing and measurement techniques. Power quality measurement methods
BS EN 50125-3:2003 Railway applications. Environmental conditions for equipment Equipment for signalling and telecommunications
BS EN 61136-1:1998 Semiconductor power convertors. Adjustable speed electric drive systems. General requirements. Rating specifications, particularly for d.c. motor drives
I.S. EN 50533:2011 RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
I.S. CLC/TS 50217:2005 GUIDE FOR IN SITU MEASUREMENTS - IN SITU MEASUREMENT OF DISTURBANCE EMISSION
CEI EN 61000-2-12 : 2004 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-12: ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC MEDIUM-VOLTAGE POWER SUPPLY SYSTEMS
EN 62586-2:2017 Power quality measurement in power supply systems - Part 2: Functional tests and uncertainty requirements
BS EN 809 : 1998 PUMPS AND PUMP UNITS FOR LIQUIDS - COMMON SAFETY REQUIREMENTS
UNE-EN 50160:2011 Voltage characteristics of electricity supplied by public electricity networks
EN 809 : 1998 COR 2010 PUMPS AND PUMP UNITS FOR LIQUIDS - COMMON SAFETY REQUIREMENTS
EN 809:1998+A1:2009 Pumps and pump units for liquids - Common safety requirements
EN 50600-2-2:2014 Information technology - Data centre facilities and infrastructures - Part 2-2: Power distribution
UNI EN 809 : 2009 PUMPS AND PUMP UNITS FOR LIQUIDS - COMMON SAFETY REQUIREMENTS
EN 61000-4-28:2000/A2:2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-28: TESTING AND MEASUREMENT TECHNIQUES - VARIATION OF POWER FREQUENCY, IMMUNITY TEST FOR EQUIPMENT WITH INPUT CURRENT NOT EXCEEDING 16 A PER PHASE
I.S. EN 61000-2-12:2003 ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC MEDIUM-VOLTAGE POWER SUPPLY SYSTEMS
I.S. EN 62274:2005 MEDICAL ELECTRICAL EQUIPMENT - SAFETY OF RADIOTHERAPY RECORD AND VERIFY SYSTEMS
08/30180966 DC : DRAFT APR 2008 BS EN 50160 - VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC DISTRIBUTION NETWORKS
CEI EN 50125-3 : 2004 RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 3: EQUIPMENT FOR SIGNALLING AND TELECOMMUNICATIONS
BS EN 16704-2-1:2016 Railway applications. Track. Safety protection on the track during work Common solutions and technologies. Technical requirements for Track Warning Systems (TWS)
BS EN 61000-2-12:2003 Electromagnetic compatibility (EMC). Environment Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems
BS EN 62274:2005 Medical electrical equipment. Safety of radiotherapy record and verify systems
02/204840 DC : DRAFT APR 2002 PREN 50217 - IN SITU MEASUREMENTS OF DISTURBANCE EMISSION
CEI EN 61800-5-2 : 2009 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 5-2: SAFETY REQUIREMENTS - FUNCTIONAL
BS EN 61000-4-14 : 1999 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-14: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE FLUCTUATION IMMUNITY TEST FOR EQUIPMENT WITH INPUT CURRENT NOT EXCEEDING 16 A PER PHASE
I.S. EN 50160:2010 VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS
I.S. EN 60146-2:2003 SEMICONDUCTOR CONVERTERS - PART 2: SELF-COMMUTATED SEMICONDUCTOR CONVERTERS INCLUDING DIRECT D.C. CONVERTERS
CEI EN 60146-1-1 : 2013 SEMICONDUCTOR CONVERTERS - GENERAL REQUIREMENTS AND LINE COMMUTATED CONVERTERS - PART 1-1: SPECIFICATION OF BASIC REQUIREMENTS
I.S. EN 50240:2006
CEI EN 50533 : 2012 RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
I.S. EN 61136-1:1996 SEMICONDUCTOR POWER CONVERTORS - ADJUSTABLE SPEED ELECTRIC DRIVE SYSTEMS GENERAL REQUIREMENTS - PART 1: RATING SPECIFICATIONS, PARTICULARLY FOR D.C. MOTOR DRIVES
DIN EN 809:2012-10 Pumps and pump units for liquids - Common safety requirements
95/214868 DC : 0 PREN 50178 - ELECTRONIC EQUIPMENT FOR USE IN POWER INSTALLATIONS
EN 16704-2-1:2016 Railway applications - Track - Safety protection on the track during work - Part 2-1: Common solutions and technologies - Technical requirements for Track Warning Systems (TWS)
UNE-EN 50533:2012 Railway applications - Three-phase train line voltage characteristics.
BS EN 61800-4:2003 Adjustable speed electrical power drive systems General requirements. Rating specifications for a.c. power drive systems above 1000 V a.c. and not exceeding 35 kV
UNE-EN 16704-2-1:2017 Railway applications - Track - Safety protection on the track during work - Part 2-1: Common solutions and technologies - Technical requirements for Track Warning Systems (TWS)
BS EN 50328:2003 Railway applications. Fixed installations. Electronic power convertors for substations
PREN 50533 : DRAFT 2009 RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
BS EN 61000-3-12:2011 Electromagnetic compatibility (EMC) Limits. Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and ≤ 75 A per phase
BS EN 61000-4-8:2010 Electromagnetic compatibility (EMC) Testing and measurement techniques. Power frequency magnetic field immunity test
BS EN 60146-1-1:2010 Semiconductor converters. General requirements and line commutated converters Specification of basic requirements
S.R. CLC/TR 50646:2015 RAILWAY APPLICATION - FIXED INSTALLATIONS - SPECIFICATION FORREVERSIBLE D.C. SUBSTATIONS
I.S. EN 62586-2:2017 POWER QUALITY MEASUREMENT IN POWER SUPPLY SYSTEMS - PART 2: FUNCTIONAL TESTS AND UNCERTAINTY REQUIREMENTS
I.S. EN 61000-3-12:2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-12: LIMITS - LIMITS FOR HARMONIC CURRENTS PRODUCED BY EQUIPMENT CONNECTED TO PUBLIC LOW-VOLTAGE SYSTEMS WITH INPUT CURRENT > 16 A AND <= 75 A PER PHASE (IEC 61000-3-12:2011 (EQV))
BS EN 61000-4-13 : 2002 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-13: TESTING AND MEASUREMENT TECHNIQUES - HARMONICS AND INTERHARMONICS INCLUDING MAINS SIGNALLING AT A.C. POWER PORT, LOW FREQUENCY IMMUNITY TESTS (IEC 61000-4-13:2002)
BS EN 50160 : 2010 VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS
I.S. EN 61000-4-28:2000 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-28: TESTING AND MEASUREMENT TECHNIQUES - VARIATION OF POWER FREQUENCY, IMMUNITY TEST FOR EQUIPMENT WITH INPUT CURRENT NOT EXCEEDING 16 A PER PHASE
EN 50328 : 2003 COR 2006 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRONIC POWER CONVERTERS FOR SUBSTATIONS
CEI EN 61800-4 : 2003 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 4: GENERAL REQUIREMENTS - RATING SPECIFICATIONS FOR A/C/ POWER DRIVE SYSTEMS ABOVE 1000 V A.C. AND NOT EXCEEDING 35 KV
EN 50160 : 2010 AMD 1 2015 VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS
BS EN 809:1998+A1:2009 Pumps and pump units for liquids. Common safety requirements
I.S. EN 61800-5-2:2017 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 5-2: SAFETY REQUIREMENTS - FUNCTIONAL
I.S. EN 61800-4:2003 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 4: GENERAL REQUIREMENTS - RATING SPECIFICATIONS FOR A.C. POWER DRIVE SYSTEMS ABOVE 1000 V A.C. AND NOT EXCEEDING 35 KV
EN 61800-3 : 2004 AMD 1 2012 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS (IEC 61800-3:2004/A1:2011)
EN 62274:2005 Medical electrical equipment - Safety of radiotherapy record and verify systems
EN 61000-4-14:1999/A2:2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-14: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE FLUCTUATION IMMUNITY TEST FOR EQUIPMENT WITH INPUT CURRENT NOT EXCEEDING 16 A PER PHASE
EN 60146-1-1:2010 Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements
EN 61800-4:2003 Adjustable speed electrical power drive systems - Part 4: General requirements - Rating specifications for a.c. power drive systems above 1 000 V a.c. and not exceeding 35 kV
EN 50533 : 2011 AMD 1 2016 RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
EN 50240:2004/corrigendum:2005
EN 60146-2:2000 Semiconductor converters - Part 2: Self-commutated semiconductor converters including direct d.c. converters
CLC/TR 50646:2015 Railway Application - Fixed Installations - Specification for reversible d.c. substations
UNE-EN 809:1999 PUMPS AND PUMP UNITS FOR LIQUIDS - COMMON SAFETY REQUIREMENTS

IEC 60038:2009 IEC standard voltages
IEC 61000-2-12:2003 Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems
IEC 60050-551:1998 International Electrotechnical Vocabulary (IEV) - Part 551: Power electronics
EN 61000-2-2:2002/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (IEC 61000-2-2:2002/A1:2017)
IEC 60050-101:1998 International Electrotechnical Vocabulary (IEV) - Part 101: Mathematics
IEC 61000-4-15:2010 Electromagnetic compatibility (EMC) - Part 4-15: Testing and measurement techniques - Flickermeter - Functional and design specifications
IEC TR 61000-2-1:1990 Electromagnetic compatibility (EMC) - Part 2: Environment - Section 1: Description of the environment - Electromagnetic environment for low-frequency conducted disturbances and signalling in public power supply systems
IEC 61000-2-2:2002+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
IEC 61000-4-7:2002+AMD1:2008 CSV Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto
IEC TR 61000-2-8:2002 Electromagnetic compatibility (EMC) - Part 2-8: Environment - Voltage dips and short interruptions on public electric power supply systems with statistical measurement results
IEC 60050-551-20:2001 International Electrotechnical Vocabulary (IEV) - Part 551-20: Power electronics - Harmonic analysis

Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.