Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 60811-507:2012

Current

Current

The latest, up-to-date edition.

Electric and optical fibre cables - Test methods for non-metallic materials - Part 507: Mechanical tests - Hot set test for cross-linked materials

Published date

15-06-2012

Sorry this product is not available in your region.

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Test method
5 Test report
Annex A (informative) - Recommended
        performance requirement
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

IEC 60811-507:2012 gives the procedure for the hot set test, which typically applies to cross-linkable compounds used for insulating and sheathing materials. IEC 60811-507:2012 cancels and replaces Clause 9 of IEC 60811-2-1:1998, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.[
]

This publication is to be read in conjunction with IEC 60811-100:2012.

Committee
CLC/TC 20
DevelopmentNote
Supersedes EN 60811-2-1. To be read in conjunction with EN 60811-100. (06/2012)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current
Supersedes

UNE-EN 50620:2017 Electric cables - Charging cables for electric vehicles
CEI EN 50290-2-29 : 2002 COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES
CEI EN 50290-2-36 : 1ED 2017 COMMUNICATION CABLES - PART 2-36: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED SILICONE RUBBER INSULATION COMPOUND
I.S. EN 50618:2014 ELECTRIC CABLES FOR PHOTOVOLTAIC SYSTEMS
I.S. EN 50620:2017 ELECTRIC CABLES - CHARGING CABLES FOR ELECTRIC VEHICLES
EN 50290-2-29:2016 Communication cables - Part 2-29: Common design rules and construction - Crosslinked polyethylene insulation compounds: instrumentation, control and field bus cables
UNE-EN 50290-2-29:2016 Communication cables - Part 2-29: Common design rules and construction - Crosslinked polyethylene insulation compounds: instrumentation, control and field bus cables
UNE 211067-2:2017 Power cables with extruded insulation and their accessories for rated voltages above 150 kV (Um = 170 kV) up to 400 kV (Um = 420 kV). Part 2: Cables with XLPE insulation and polyolefin compound sheath or high density polyethylene (HDPE) compound sheath.
I.S. EN 50290-2-29:2016 COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES
UNE 211632-4A:2017 Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 4A: Cables with XLPE insulation and polyolefin compound sheath (Types 1, 2 and 3) or high density polyethylene (HDPE) compound sheath.
UNE-HD 603-5X:2007 Distribution cables of rated voltage 0,6/1 kV. Part 5: XLPE insulated cables unarmoured. Section X: Polyolefin sheathed cables without concentric conductor (Type 5X-1)
CEI EN 50620 : 1ED 2017 ELECTRIC CABLES - CHARGING CABLES FOR ELECTRIC VEHICLES
PREN 50620 : DRAFT 2014 CHARGING CABLES FOR ELECTRIC VEHICLES
UNE-EN 50618:2015 Electric cables for photovoltaic systems
UNE-HD 603-5N:2007 Distribution cables of rated voltage 0,6/1 kV. Part 5: XLPE insulated cables unarmoured. Section N: PVC sheathed cables without concentric conductor. (Type 5N)
16/30336762 DC : 0 BS EN 50290-2-29 - COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES
UNE-EN 50290-2-36:2016 Communication cables - Part 2-36: Common design rules and construction - Crosslinked Silicone rubber insulation compound
EN 50620:2017 Electric cables - Charging cables for electric vehicles
BS EN 50620:2017 Electric cables. Charging cables for electric vehicles (BT(DE/NOT)259)
BS EN 50618:2014 Electric cables for photovoltaic systems (BT(DE/NOT)258)
14/30288755 DC : 0 BS EN 50620 - CHARGING CABLES FOR ELECTRIC VEHICLES
BS EN 50290-2-29:2016 Communication cables Common design rules and construction. Crosslinked polyethylene insulation compounds: instrumentation, control and field bus cables
PREN 50290-2-29 : DRAFT 2016 COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES
UNE 211632-6A:2017 Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 6A: Cables with HEPR insulation and polyolefin compound sheath (Types 1, 2 and 3) or high density polyethylene (HDPE) compound sheath.
I.S. EN 50290-2-36:2016 COMMUNICATION CABLES - PART 2-36: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED SILICONE RUBBER INSULATION COMPOUND
EN 50290-2-36:2016 Communication cables - Part 2-36: Common design rules and construction - Crosslinked Silicone rubber insulation compound
EN 50618:2014 Electric cables for photovoltaic systems

IEC 60811-501:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds
EN 60811-501:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds
IEC 60811-401:2012+AMD1:2017 CSV Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven
IEC 60811-202:2012+AMD1:2017 CSV Electric and optical fibre cables - Test methods for non-metallic materials - Part 202: General tests - Measurement of thickness of non-metallic sheath
EN 60811-100:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General
IEC 60811-201:2012+AMD1:2017 CSV Electric and optical fibre cables - Test methods for non-metallic materials - Part 201: General tests - Measurement of insulation thickness
IEC 60811-2-1:1998+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
IEC 60811-100:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.