EN 60811-507:2012
Current
The latest, up-to-date edition.
Electric and optical fibre cables - Test methods for non-metallic materials - Part 507: Mechanical tests - Hot set test for cross-linked materials
15-06-2012
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Test method
5 Test report
Annex A (informative) - Recommended
performance requirement
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
IEC 60811-507:2012 gives the procedure for the hot set test, which typically applies to cross-linkable compounds used for insulating and sheathing materials. IEC 60811-507:2012 cancels and replaces Clause 9 of IEC 60811-2-1:1998, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.[
]
This publication is to be read in conjunction with IEC 60811-100:2012.
Committee |
CLC/TC 20
|
DevelopmentNote |
Supersedes EN 60811-2-1. To be read in conjunction with EN 60811-100. (06/2012)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Supersedes |
Standards | Relationship |
IEC 60811-507:2012 | Identical |
NF EN 60811-507 : 2012 | Identical |
NEN EN IEC 60811-507 : 2012 | Identical |
I.S. EN 60811-507:2012 | Identical |
PN EN 60811-507 : 2012 | Identical |
VDE 0473-811-507 : 2012 | Identical |
DIN EN 60811-507 : 2012 | Identical |
UNE-EN 60811-507:2012 | Identical |
BS EN 60811-507:2012 | Identical |
CEI EN 60811-507 : 2015 | Identical |
UNE-EN 50620:2017 | Electric cables - Charging cables for electric vehicles |
CEI EN 50290-2-29 : 2002 | COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES |
CEI EN 50290-2-36 : 1ED 2017 | COMMUNICATION CABLES - PART 2-36: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED SILICONE RUBBER INSULATION COMPOUND |
I.S. EN 50618:2014 | ELECTRIC CABLES FOR PHOTOVOLTAIC SYSTEMS |
I.S. EN 50620:2017 | ELECTRIC CABLES - CHARGING CABLES FOR ELECTRIC VEHICLES |
EN 50290-2-29:2016 | Communication cables - Part 2-29: Common design rules and construction - Crosslinked polyethylene insulation compounds: instrumentation, control and field bus cables |
UNE-EN 50290-2-29:2016 | Communication cables - Part 2-29: Common design rules and construction - Crosslinked polyethylene insulation compounds: instrumentation, control and field bus cables |
UNE 211067-2:2017 | Power cables with extruded insulation and their accessories for rated voltages above 150 kV (Um = 170 kV) up to 400 kV (Um = 420 kV). Part 2: Cables with XLPE insulation and polyolefin compound sheath or high density polyethylene (HDPE) compound sheath. |
I.S. EN 50290-2-29:2016 | COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES |
UNE 211632-4A:2017 | Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 4A: Cables with XLPE insulation and polyolefin compound sheath (Types 1, 2 and 3) or high density polyethylene (HDPE) compound sheath. |
UNE-HD 603-5X:2007 | Distribution cables of rated voltage 0,6/1 kV. Part 5: XLPE insulated cables unarmoured. Section X: Polyolefin sheathed cables without concentric conductor (Type 5X-1) |
CEI EN 50620 : 1ED 2017 | ELECTRIC CABLES - CHARGING CABLES FOR ELECTRIC VEHICLES |
PREN 50620 : DRAFT 2014 | CHARGING CABLES FOR ELECTRIC VEHICLES |
UNE-EN 50618:2015 | Electric cables for photovoltaic systems |
UNE-HD 603-5N:2007 | Distribution cables of rated voltage 0,6/1 kV. Part 5: XLPE insulated cables unarmoured. Section N: PVC sheathed cables without concentric conductor. (Type 5N) |
16/30336762 DC : 0 | BS EN 50290-2-29 - COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES |
UNE-EN 50290-2-36:2016 | Communication cables - Part 2-36: Common design rules and construction - Crosslinked Silicone rubber insulation compound |
EN 50620:2017 | Electric cables - Charging cables for electric vehicles |
BS EN 50620:2017 | Electric cables. Charging cables for electric vehicles (BT(DE/NOT)259) |
BS EN 50618:2014 | Electric cables for photovoltaic systems (BT(DE/NOT)258) |
14/30288755 DC : 0 | BS EN 50620 - CHARGING CABLES FOR ELECTRIC VEHICLES |
BS EN 50290-2-29:2016 | Communication cables Common design rules and construction. Crosslinked polyethylene insulation compounds: instrumentation, control and field bus cables |
PREN 50290-2-29 : DRAFT 2016 | COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES |
UNE 211632-6A:2017 | Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 6A: Cables with HEPR insulation and polyolefin compound sheath (Types 1, 2 and 3) or high density polyethylene (HDPE) compound sheath. |
I.S. EN 50290-2-36:2016 | COMMUNICATION CABLES - PART 2-36: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED SILICONE RUBBER INSULATION COMPOUND |
EN 50290-2-36:2016 | Communication cables - Part 2-36: Common design rules and construction - Crosslinked Silicone rubber insulation compound |
EN 50618:2014 | Electric cables for photovoltaic systems |
IEC 60811-501:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds |
EN 60811-501:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds |
IEC 60811-401:2012+AMD1:2017 CSV | Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven |
IEC 60811-202:2012+AMD1:2017 CSV | Electric and optical fibre cables - Test methods for non-metallic materials - Part 202: General tests - Measurement of thickness of non-metallic sheath |
EN 60811-100:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General |
IEC 60811-201:2012+AMD1:2017 CSV | Electric and optical fibre cables - Test methods for non-metallic materials - Part 201: General tests - Measurement of insulation thickness |
IEC 60811-2-1:1998+AMD1:2001 CSV | Common test methods for insulating and sheathing materials of electric and optical cables - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests |
IEC 60811-100:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.