FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Types of test method
5 Types of test specimen
6 Published static test methods
7 Published dynamic test methods
8 Overview of methods and relevance of data
Annex A (informative) - Repeatability and reproducibility
data - NBS smoke chamber - Interlaboratory tests
from the French standard NF C20-902-1 and NF C20-902-2
Annex B (informative) - Repeatability and reproducibility
data - ISO 5659-2
Annex C (informative) - Repeatability and reproducibility
data - 'Three metre cube' smoke chamber - French
interlaboratory tests according to IEC 61034-2
Annex D (informative) - Repeatability and reproducibility
data - NFPA 262
Annex E (informative) - Precision data of smoke measurement
in ISO 5660-2
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Bibliography
Defines a summary of the test methods that are used in the assessment of smoke obscuration.
Committee |
SR 89
|
DevelopmentNote |
To be read in conjunction with EN 60695-6-1. (10/2011)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NF EN 60695-6-2 : 2012 | Identical |
UNE-EN 60695-6-2:2012 | Identical |
NEN EN IEC 60695-6-2 : 2011 | Identical |
NBN EN 60695-6-2 : 2011 | Identical |
DIN EN 60695-6-2 : 2014 | Identical |
BS EN 60695-6-2:2011 | Identical |
PN EN 60695-6-2 : 2012 | Identical |
I.S. EN 60695-6-2:2011 | Identical |
CEI EN 60695-6-2 : 2013 | Identical |
IEC 60695-6-2:2011 | Identical |
VDE 0471-6-2 : 2014 | Identical |
BS EN 60695-1-40:2014 | Fire hazard testing Guidance for assessing the fire hazard of electrotechnical products. Insulating liquids |
BS EN 60695-6-1 : 2005 | FIRE HAZARD TESTING - PART 6-1: SMOKE OBSCURATION - GENERAL GUIDANCE |
EN 60695-6-1:2005/A1:2010 | FIRE HAZARD TESTING - PART 6-1: SMOKE OBSCURATION - GENERAL GUIDANCE |
I.S. EN 60695-1-40:2014 | FIRE HAZARD TESTING - PART 1-40: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - INSULATING LIQUIDS |
I.S. EN 60695-6-1:2005 | FIRE HAZARD TESTING - PART 6-1: SMOKE OBSCURATION - GENERAL GUIDANCE |
UNE-EN 60695-1-40:2014 | Fire hazard testing - Part 1-40: Guidance for assessing the fire hazard of electrotechnical products - Insulating liquids |
IEC 60695-1-10:2016 | Fire hazard testing - Part 1-10: Guidance for assessing the fire hazard of electrotechnical products - General guidelines |
CEI EN 60695-1-40 : 2014 | FIRE HAZARD TESTING - PART 1-40: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - INSULATING LIQUIDS |
EN 60695-1-40:2014 | Fire hazard testing - Part 1-40: Guidance for assessing the fire hazard of electrotechnical products - Insulating liquids |
EN 50399 : 2011 AMD 1 2016 | COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - HEAT RELEASE AND SMOKE PRODUCTION MEASUREMENT ON CABLES DURING FLAME SPREAD TEST - TEST APPARATUS, PROCEDURES, RESULTS |
IEC TS 60695-6-31:2013 | Fire hazard testing - Part 6-31: Smoke obscuration - Small-scale static test - Materials |
UL 1685:4ED 2015-07-07 | Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables |
NFPA 262 : 2015 | METHOD OF TEST FOR FLAME TRAVEL AND SMOKE OF WIRES AND CABLES FOR USE IN AIR-HANDLING SPACES |
ISO/TR 5924:1989 | Fire tests — Reaction to fire — Smoke generated by building products (dual-chamber test) |
EN 50289-4-11:2002 | Communication cables - Specifications for test methods - Part 4-11: Environmental test methods - A horizontal integrated fire test method |
ISO 5659-2:2017 | Plastics — Smoke generation — Part 2: Determination of optical density by a single-chamber test |
89/106/EEC : 1988 | COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS |
ISO 5660-2:2002 | Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 2: Smoke production rate (dynamic measurement) |
IEC 60695-6-1:2005+AMD1:2010 CSV | Fire hazard testing - Part 6-1: Smoke obscuration - General guidance |
BS 6401:1983 | Method for measurement, in the laboratory, of the specific optical density of smoke generated by materials |
ISO 13943:2017 | Fire safety — Vocabulary |
NFC 20 19902-1 : 1990 | FIRE HAZARD TESTING - TEST METHODS - DETERMINATION OF SMOKE OPACITY WITHOUT AIR-CHANGE - PART 1: METHODOLOGY AND TEST DEVICES |
EN 61034-2:2005/A1:2013 | MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 2: TEST PROCEDURE AND REQUIREMENTS (IEC 61034-2:2005/A1:2013) |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
NFC 20 19902-2-1 : 1990 | FIRE HAZARD TESTING - TEST METHODS - DETERMINATION OF SMOKE OPACITY WITHOUT AIR-CHANGE - PART 2-1: TEST METHODS FOR MATERIALS USED IN ELECTRIC CABLES AND IN OPTICAL FIBER CABLES |
ASTM E 662 : 2017-02 | TEST METHOD FOR SPECIFIC OPTICAL DENSITY OF SMOKE GENERATED BY SOLID MATERIALS |
EN ISO 13943:2017 | Fire safety - Vocabulary (ISO 13943:2017) |
ISO 5725-2:1994 | Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method |
EN 61034-1:2005/A1:2014 | MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 1: TEST APPARATUS (IEC 61034-1:2005/A1:2013) |
EN 60695-6-1:2005/A1:2010 | FIRE HAZARD TESTING - PART 6-1: SMOKE OBSCURATION - GENERAL GUIDANCE |
ISO 19706:2011 | Guidelines for assessing the fire threat to people |
IEC 61034-2:2005+AMD1:2013 CSV | Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements |
IEC 60332-3-10:2000+AMD1:2008 CSV | Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus |
IEC 61034-1:2005+AMD1:2013 CSV | Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus |
ASTM E 1354 : 2017 : REDLINE | Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.