EN 60599:2016
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Mineral oil-filled electrical equipment in service - Guidance on the interpretation of dissolved and free gases analysis
15-01-2016
21-10-2018
IEC 60599:2015 is available as IEC 60599:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60599:2015 describes how the concentrations of dissolved gases or free gases may be interpreted to diagnose the condition of oil-filled electrical equipment in service and suggest future action. This standard is applicable to electrical equipment filled with mineral insulating oil and insulated with cellulosic paper or pressboard-based solid insulation. Information about specific types of equipment such as transformers (power, instrument, industrial, railways, distribution), reactors, bushings, switchgear and oil-filled cables is given only as an indication in the application notes. This standard may be applied, but only with caution, to other liquid-solid insulating systems. This third edition cancels and replaces the second edition published in 1999 and Amendment 1:2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) revision of 5.5, 6.1, 7, 8, 9, 10, A.2.6, A.3, A.7;
b) addition of new sub-clause 4.3;
c) expansion of the Bibliography;
d) revision of Figure 1;
e) addition of Figure B.4.
| Committee |
CLC/SR 10
|
| DevelopmentNote |
Supersedes HD 397. (07/2007)
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Withdrawn
|
| Supersedes |
| Standards | Relationship |
| NEN EN IEC 60599 : 2016 | Identical |
| I.S. EN 60599:2016 | Identical |
| NBN EN 60599 : 2016 | Identical |
| BS EN 60599:2016 | Identical |
| PN EN 60599 : 2016 | Identical |
| SS-EN 60599 : 2016 | Identical |
| NF EN 60599 : 2016 | Identical |
| IEC 60599:2015 | Identical |
| CEI EN 60599 : 2016 | Identical |
| VDE 0370-7 : 2016 | Identical |
| DIN EN 60599 : 2016 | Identical |
| UNE-EN 60599:2016 | Identical |
| BS EN 61869-1:2009 | Instrument transformers General requirements |
| S.R. CLC/TR 50503:2010 | GUIDELINES FOR THE INVENTORY CONTROL, MANAGEMENT, DECONTAMINATION AND/OR DISPOSAL OF ELECTRICAL EQUIPMENT AND INSULATING LIQUIDS CONTAINING PCBS |
| 06/30159746 DC : 0 | BS EN 50503 - FLUIDS FOR ELECTROTECHNICAL APPLICATIONS - STANDARD FOR THE INVENTORY CONTROL, MANAGEMENT, DECONTAMINATION AND/OR DISPOSAL OF ELECTRICAL EQUIPMENT AND INSULATING LIQUIDS CONTAINING PCBS |
| BS EN 60214-1:2014 | Tap-changers Performance requirements and test methods |
| BS EN 60567:2011 | Oil-filled electrical equipment. Sampling of gases and analysis of free and dissolved gases. Guidance |
| BS EN 61181 : 2007 | MINERAL OIL-FILLED ELECTRICAL EQUIPMENT - APPLICATION OF DISSOLVED GAS ANALYSIS (DGA) TO FACTORY TESTS ON ELECTRICAL EQUIPMENT |
| CEI EN 60567 : 2012 | OIL-FILLED ELECTRICAL EQUIPMENT - SAMPLING OF GASES AND ANALYSIS OF FREE AND DISSOLVED GASES - GUIDANCE |
| I.S. EN 60567:2011 | OIL-FILLED ELECTRICAL EQUIPMENT - SAMPLING OF GASES AND ANALYSIS OF FREE AND DISSOLVED GASES - GUIDANCE (IEC 60567:2011 (EQV)) |
| CLC/TR 50503:2010 | Guidelines for the inventory control, management, decontamination and/or disposal of electrical equipment and insulating liquids containing PCBs |
| EN 61181:2007/A1:2012 | MINERAL OIL-FILLED ELECTRICAL EQUIPMENT - APPLICATION OF DISSOLVED GAS ANALYSIS (DGA) TO FACTORY TESTS ON ELECTRICAL EQUIPMENT (IEC 61181:2007/A1:2012) |
| EN 61869-1:2009 | Instrument transformers - Part 1: General requirements |
| EN 60567:2011 | Oil-filled electrical equipment - Sampling of gases and analysis of free and dissolved gases - Guidance |
| EN 60214-1:2014 | Tap-changers - Part 1: Performance requirements and test methods |
| UNE-EN 61869-1:2010 | Instrument transformers -- Part 1: General requirements |
| UNE-EN 60567:2012 | Oil-filled electrical equipment - Sampling of gases and analysis of free and dissolved gases - Guidance |
| IEC 60050-212:2010 | International Electrotechnical Vocabulary (IEV) - Part 212: Electrical insulating solids, liquids and gases |
| IEC 60475:2011 | Method of sampling insulating liquids |
| IEC 60567:2011 | Oil-filled electrical equipment - Sampling of gases and analysis of free and dissolved gases - Guidance |
| EN 61198:1994 | Mineral insulating oils - Methods for the determination of 2-furfural and related compounds |
| IEC 60050-321:1986 | International Electrotechnical Vocabulary (IEV) - Part 321: Instrument transformers |
| ASTM D 7150 : 2013 : REDLINE | Standard Test Method for the Determination of Gassing Characteristics of Insulating Liquids Under Thermal Stress |
| IEC 61198:1993 | Mineral insulating oils - Methods for the determination of 2-furfural and related compounds |
| EN 60567:2011 | Oil-filled electrical equipment - Sampling of gases and analysis of free and dissolved gases - Guidance |
| EN 60475:2011 | Method of sampling insulating liquids |