EN 60129:1994/A2:1996
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES
01-07-2002
12-01-2013
Clause
1. Scope
2. Normal and special service conditions
3. Definitions
3.101 General terms
3.102 Switching devices
3.103 Parts of switching devices
3.104 Operation (of a mechanical switching device)
3.105 Characteristic quantities
4. Rating
4.1 Rated voltage
4.2 Rated insulation level
4.3 Rated frequency
4.4 Rated normal current and temperature rise
4.5 Rated short-time withstand current
4.6 Rated peak withstand current
4.7 Rated duration of short circuit
4.8 Rated supply voltage of closing and opening devices
and auxiliary circuits
4.9 Rated supply frequency of operating devices and
auxiliary circuits
4.10 Rated pressure of compressed gas supply for operation
4.101 Rated short-circuit making current
4.102 Rated contact zone
4.103 Rated mechanical terminal load
4.104 Rated values of maximum force required for manual
operation (under consideration)
4.105 Behaviour when carrying rated peak withstand current
and rated short-time withstand current
4.106 Behaviour of earthing switches when making
short-circuit currents
4.107 Co-ordination of rated voltages, rated normal
currents and rated peak withstand currents
5. Design and construction
5.1 Requirements for liquids in disconnectors and
earthing switches
5.2 Requirements for gases in disconnectors and earthing
switches
5.3 Earthing of disconnectors and earthing switches
5.4 Auxiliary equipment
5.5 Dependent power closing
5.6 Stored energy closing
5.7 Operation of releases
5.8 Low and high pressure interlocking devices
5.9 Nameplates
5.101 Special requirements for earthing switches
5.102 Requirements in respect of the isolating distance of
disconnectors
5.103 Mechanical strength
5.104 Position of the movable contact system and its
indicating or signalling devices
6. Type tests
6.1 Dielectric tests
6.2 Radio interference voltage (r.i.v.) tests
6.3 Temperature-rise tests
6.4 Measurement of the resistance of the main circuit
6.5 Short-time and peak withstand current tests
6.101 Tests to prove the short-circuit making performance
of earthing switches
6.102 Operating and mechanical endurance tests
6.103 Operation under severe ice conditions
6.104 Operation at the temperature limits
7. Routine tests
7.1 Power-frequency voltage withstand dry tests on the
main circuit
7.2 Voltage withstand tests on auxiliary and control
circuits
7.3 Measurement of the resistance of the main circuit
7.101 Mechanical operating tests
8. Guide to the selection of switching devices for
service
8.101 General
8.102 Selection of rated vales for normal service
conditions
9. Information to be given with enquiries, tenders and
orders
9.101 Information to be given with enquiries and orders
9.102 Information to be given with tenders
10. Rules for transport, storage, erection and
maintenance
10.1 Conditions during transport, storage and erection
10.2 Erection
10.3 Maintenance
Figures
Annex ZA: Other international publications quoted in this
standard with the references of the relevant
European publications
Applies to alternating current disconnectors and earthing switches for voltages above 1,000 V and for service frequencies up to and including 60 Hz. Includes the following sections: definitions, rating, type tests, routine tests, and design and construction.
Committee |
TC 17A
|
DevelopmentNote |
Supersedes HD 408. (06/2005)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
DIN EN 60129 : 1998 | Identical |
IEC 60129:1984 | Identical |
UNE EN 60129 : 1996 A2 1997 | Identical |
BS EN 60129:1994 | Identical |
I.S. EN 60129:1994 | Identical |
VDE 0670-2 : 1998 | Identical |
NF EN 60129 : 94 AMD 2 96 | Identical |
CEI EN 60129 : 4ED 1998 | Identical |
SN EN 60129 : 1994 AMD 2 1996 | Identical |
NBN EN 60129 : 95 AMD 1 97 | Identical |
NEN 10129 : AMD 1 94 | Identical |
BS EN 45510-2-7:2002 | Guide for the procurement of power station equipment. Electrical equipment Switchgear and controlgear |
DIN EN 45510-2-7:2003-12 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
CEI EN 61116 : 1996 | ELECTROMECHANICAL EQUIPMENT GUIDE FOR SMALL HYDROELECTRIC INSTALLATIONS |
I.S. EN 50123-4:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES |
EN 60204-11:2000/corrigendum:2010 | SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 11: REQUIREMENTS FOR HV EQUIPMENT FOR VOLTAGES ABOVE 1000 V A.C. OR 1500 V D.C. AND NOT EXCEEDING 36 KV |
CEI EN 60265-1 : 2000 | INTERRUPTEURS A HAUTE TENSION - PARTIE 1: INTERRUPTEURS POUR TENSIONS ASSIGNEES SUPERIEURES A 1 KV ET INFERIEURES A 52 KV |
BS EN 50123-2:2003 | Railway applications. Fixed installations. D.C. switchgear D.C. circuit breakers |
CEI UNI EN 45510-2-7 : 2006 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
EN 50123-7-2:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 7-2: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating current transducers and other current measuring devices |
BS EN 50123-1:2003 | Railway applications. Fixed installations. D.C. switchgear General |
BS EN 60204-11 : 2001 | SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 11: REQUIREMENTS FOR HV EQUIPMENT FOR VOLTAGES ABOVE 1000 V A.C. OR 1500 V D.C. AND NOT EXCEEDING 36 KV |
I.S. EN 50123-7-2:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING CURRENT TRANSDUCERS AND OTHER CURRENT MEASURING DEVICES |
BS EN 50123-7-1:2003 | Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Measurement, control and protection devices for specific use in d.c. traction systems. Application guide |
CEI EN 50123-1 : 2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 1: GENERAL |
I.S. EN 45510-2-7:2002 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
I.S. EN 60204-11:2000 | SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES PART 11: REQUIREMENTS FOR HV EQUIPMENT FOR VOLTAGES ABOVE 1000 V A.C. OR 1500 V D.C. AND NOT EXCEEDING 36 KV |
BS EN 60470:2001 | High-voltage alternating current contactors and contactor-based motor starters |
BS EN 50123-7-3:2003 | Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Isolating voltage transducers and other voltage measuring devices |
I.S. EN 50123-3:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES |
UNI CEI EN 45510-2-7 : 2011 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
I.S. EN 50123-1:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - GENERAL |
I.S. EN 50123-2:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - D.C. CIRCUIT BREAKERS |
I.S. EN 50123-7-3:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING VOLTAGE TRANSDUCERS AND OTHER VOLTAGE MEASURING DEVICES |
EN 45510-2-7:2002 | Guide for procurement of power station equipment - Part 2-7: Electrical equipment - Switchgear and controlgear |
EN 50123-7-3:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 7-3: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating voltage transducers and other voltage measuring devices |
CEI 32-14 : 1998 | HIGH-VOLTAGE FUSES - PART 2: EXPULSION FUSES |
BS EN 60298:1996 | A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
I.S. EN 61116:1995 | ELECTROMECHANICAL EQUIPMENT GUIDE FOR SMALL HYDROELECTRIC INSTALLATIONS |
BS EN 60265-1:1998 | Specification for high-voltage switches Switches for rated voltages above 1 kV and less than 52 kV |
BS EN 50123-7-2:2003 | Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Isolating current transducers and other current measuring devices |
EN 50123-1:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 1: General |
EN 50123-7-1:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 7-1: Measurement, control and protection devices for specific use in d.c. traction systems - Application guide |
EN 50123-4:2003/A1:2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES |
EN 50123-2:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 2: D.C. circuit breakers |
EN 61116:1994 | Electromechanical equipment guide for small hydroelectric installations |
EN 50123-3:2003/A1:2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.