EN 60099-5:2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Surge arresters - Part 5: Selection and application recommendations
01-03-2018
16-08-2013
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General principles for the application of surge
arresters
5 Surge arrester fundamentals and applications issues
6 Insulation coordination and surge arrester
applications
7 Surge arresters for special applications
8 Asset management of surge arresters
Annex A (informative) - Determination of temporary
overvoltages due to earth faults
Annex B (informative) - Current practice
Annex C (informative) - Arrester modelling techniques
for studies involving insulation coordination
and energy requirements
Annex D (informative) - Diagnostic indicators of
metal-oxide surge arresters in service
Annex E (informative) - Typical data needed from arrester
manufacturers for proper selection of surge
arresters
Annex F (informative) - Typical maximum residual
voltages for metal-oxide arresters without gaps
according to IEC 60099-4
Annex G (informative) - Steepness reduction of
incoming surge with additional line terminal
surge capacitance
Annex H (informative) - End of life and replacement
of old gapped SiC-arresters
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
IEC 60099-5:2013(E) is not a mandatory standard but provides information, guidance, and recommendations for the selection and application of surge arresters to be used in three-phase systems with nominal voltages above 1 kV. It applies to gapless metal-oxide surge arresters as defined in IEC 60099-4, to surge arresters containing both series and parallel gapped structure - rated 52 kV and less as defined in IEC 60099-6 and metal-oxide surge arresters with external series gap for overhead transmission and distribution lines (EGLA) as defined in IEC 60099-8. In Annex H, some aspects regarding the old type of SiC gapped arresters are discussed. This second edition cancels and replaces the first edition published in 1996 and its amendment 1 published in 1999. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Expanded discussion of different types of arresters and their application, including additions of discussion on transmission of line arresters, arresters for shunt capacitor switching arresters for series capacitor protection, application of arresters between phases connecting arresters in parallel; - Addition of section on asset management, including: managing surge arresters in the power grid, arrester maintenance, significantly expanded discussion of performance diagnostic tools, end-of-life considerations; - New annexes dealing with: arrester modelling for system studies, example of data needed for specifying arresters. Key words: selection and application of surge arrestors, nominal voltages above 1 kV
Committee |
CLC/SR 37
|
DevelopmentNote |
Redesignated as EN IEC 60099-5. (03/2018)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
UNE-EN 60099-5:2000 | Identical |
NBN EN 60099-5 : 2013 | Identical |
VDE 0675-5 : 2014 | Identical |
NEN EN IEC 60099-5 : 2013 | Identical |
BS EN 60099-5:2013 | Identical |
I.S. EN 60099-5:2013 | Identical |
CEI EN 60099-5:2018 | Identical |
NF EN 60099-5 : 2017 | Identical |
CEI EN 60099-5 : 2014 | Identical |
PN EN 60099-5 : 2014 | Identical |
IEC 60099-5:2013 | Identical |
DIN EN 60099-5 : 2014 | Identical |
SN EN 60099-5 : 1996 AMD 1 1999 | Identical |
SN EN 60099-5:2013 | Identical |
BS EN IEC 60794-1-23:2019 | Identical |
UNE-EN 60099-5:2013 | Identical |
PNE-FprEN 60099-5 | Identical |
UNE-EN 61400-24:2011 | Wind turbines - Part 24: Lightning protection |
CEI CLC/TS 50544 : 2011 | LOW VOLTAGE D.C. SURGE PROTECTIVE DEVICE FOR TRACTION SYSTEMS - SELECTION AND APPLICATION RULES FOR SURGE ARRESTERS |
UNE-EN 60099-4:2016 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
EN 60071-5:2015 | Insulation co-ordination - Part 5: Procedures for high-voltage direct current (HVDC) converter stations |
CLC/TS 50544:2010 | Low voltage d.c. surge protective device for traction systems - Selection and application rules for surge arresters |
S.R. CLC/TS 50544:2010 | LOW VOLTAGE D.C. SURGE PROTECTIVE DEVICE FOR TRACTION SYSTEMS - SELECTION AND APPLICATION RULES FOR SURGE ARRESTERS |
DD CLC/TS 50544:2010 | Low voltage d.c. surge protective device for traction systems. Selection and application rules for surge arresters |
S.R. CLC/TS 61643-12:2009 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 12: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER DISTRIBUTION SYSTEMS - SELECTION AND APPLICATION PRINCIPLES |
DD CLC/TS 61643-12:2009 | Low-voltage surge protective devices Surge protective devices connected to low-voltage power distribution systems. Selection and application principles |
BS EN 60071-5:2015 | Insulation co-ordination Procedures for high-voltage direct current (HVDC) converter stations |
CEI EN 61400-24 : 2011 | WIND TURBINES - PART 24: LIGHTNING PROTECTION |
UNE-CLC/TS 61643-12:2012 | Low-voltage surge protective devices -- Part 12: Surge protective devices connected to low-voltage power distribution systems - Selection and application principles |
CEI EN 60071-2 : 1998 | INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDE |
BS EN 61400-24:2010 | Wind turbines Lightning protection |
I.S. EN 61400-24:2010 | WIND TURBINES - PART 24: LIGHTNING PROTECTION |
BS EN 60071-2:1997 | Insulation co-ordination Application guide |
EN 61400-24:2010 | Wind turbines - Part 24: Lightning protection |
CLC/TS 61643-12:2009 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 12: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER DISTRIBUTION SYSTEMS - SELECTION AND APPLICATION PRINCIPLES |
IEC 62271-200:2011 | High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
EN 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
IEC TR 60071-4:2004 | Insulation co-ordination - Part 4: Computational guide to insulation co-ordination and modelling of electrical networks |
IEC TS 60815-2:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems |
EN 62271-203:2012 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
IEC TR 62271-300:2006 | High-voltage switchgear and controlgear - Part 300: Seismic qualification of alternating current circuit-breakers |
EN 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
IEC 60099-6:2002 | Surge arresters - Part 6: Surge arresters containing both series and parallel gapped structures - Rated 52 kV and less |
EN 60507:2014 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
IEC 62271-203:2011 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
EN 60071-1:2006/A1:2010 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
IEC 60099-8:2017 | Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV |
EN 60071-2:1997 | Insulation co-ordination - Part 2: Application guide |
IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC TS 60815-1:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles |
EN 62271-200:2012/AC:2015 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011) |
IEC TS 60815-3:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 3: Polymer insulators for a.c. systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.