EN 60099-1:1994/A1:1999
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
SURGE ARRESTERS - PART 1: NON-LINEAR RESISTOR TYPE GAPPED SURGE ARRESTERS FOR A.C. SYSTEMS
05-05-2015
12-01-2013
Foreword
Introduction
Section 1: General
1.1 Scope
1.2 Normative references
Section 2: Definitions
2.1 Surge arrestor
2.2 Non-linear resistor type gapped arrester
2.3 Series gap of an arrester
2.4 Non-linear series resistor of an arrester
2.5 Section of an arrester
2.6 Unit of an arrester
2.7 Pressure-relief device of an arrester
2.8 Rated voltage of an arrester
2.9 Rated frequency of an arrester
2.10 Disruptive discharge
2.11 Puncture
2.12 Flashover
2.13 Sparkover of an arrester
2.14 Impulse
2.15 Rectangular impulse
2.16 Peak (crest) value of an impulse
2.17 Front of an impulse
2.18 Tail of an impulse
2.19 Full-wave voltage impulse
2.20 Chopped voltage impulse
2.21 Prospective peak (crest) value of a chopped
voltage impulse
2.22 Virtual origin of an impulse
2.23 Virtual front time of an impulse (T1)
2.24 Virtual steepness of the front of an impulse
2.25 Virtual time to half value on the tail of an
impulse (T2)
2.26 Designation of an impulse shape
2.27 Standard lightning voltage impulse
2.28 Switching voltage impulse
2.29 Virtual duration of the peak of a rectangular
impulse
2.30 Virtual total duration of a rectangular impulse
2.31 Peak (crest) value of opposite polarity of an
impulse
2.32 Discharge current of an arrester
2.33 Nominal discharge current of an arrester
2.34 Follow-current of an arrester
2.35 Residual voltage (discharge voltage) of an
arrester
2.36 Power-frequency sparkover voltage of an arrester
2.37 Impulse sparkover voltage of an arrester
2.38 Front-of-wave impulse sparkover of an arrester
2.39 Standard lightning impulse sparkover voltage of
an arrester
2.40 Time to sparkover of an arrester
2.41 Impulse sparkover-voltage/time curve
2.42 Prospective current
2.43 Type tests (design tests)
2.44 Routine tests
2.45 Acceptance tests
2.46 Protective characteristics of an arrester
2.47 Arrester disconnector
Section 3: Identification and classification
3.1 Arrester identification
3.2 Arrester classification
Section 4: Standard ratings
4.1 Standard voltage ratings
4.2 Standard rated frequencies
4.3 Standard nominal discharge currents
4.4 Service conditions
4.4.1 Normal service conditions
4.4.2 Abnormal service conditions
Section 5: Requirements
5.1 Power-frequency sparkover voltage
5.2 Standard lightning impulse sparkover voltage
5.3 Front-of-wave impulse sparkover voltage
5.4 Switching impulse sparkover voltage
5.5 Lightning impulse residual voltage
5.6 Switching impulse residual voltage
5.7 High-current impulse withstand
5.8 Long-duration current withstand
5.9 Operating-duty
5.10 Pressure-relief
5.11 Disconnectors
5.11.1 Disconnector withstand
5.11.2 Disconnector operation
Section 6: General testing procedure
6.1 Test samples and measurements
6.2 Power-frequency voltage tests
6.3 Wet tests
6.4 Artificial-pollution tests
Section 7: Routine and acceptance tests
7.1 Routine tests
7.2 Acceptance tests
Section 8: Type tests (design tests)
8.1 General
8.2 Power-frequency voltage sparkover tests
8.3 Voltage impulse sparkover tests
8.3.1 General
8.3.2 Standard lightning impulse sparkover test
8.3.3 Lightning impulse sparkover-voltage/time
curve test
8.3.4 Front-of-wave impulse sparkover test
8.3.5 Switching impulse sparkover-voltage/time
curve test
8.4 Measurement of residual voltage
8.4.1 Lightning impulse residual voltage
8.4.2 Switching impulse residual voltage
8.5 Current impulse withstand test
8.5.1 General
8.5.2 High-current impulse test
8.5.3 Long-duration current impulse test
8.6 Operating-duty test
8.7 Pressure-relief tests
8.7.1 General
8.7.2 High-current pressure-relief tests
8.7.3 Low-current pressure-relief tests
8.8 Tests of arrester disconnectors
8.8.1 General
8.8.2 Current impulse withstand and
operating-duty tests
8.8.3 Disconnector operation
Annexes
A (normative) Abnormal service conditions
B (informative) Typical information given with
enquiries and tenders
C (informative) Selection of the long-duration
discharge class of heavy-duty arresters
D (informative) Typical circuit for a
distributed-constant impulse generator for the
long-duration current impulse test according to
8.5.3
E (informative) Typical circuit for operating-duty
test according to 8.6
ZA (normative) Other international publications
quoted in this standard with the references of
the relevant European publications
Applies to surge protective devices designed for repeated operation to limit voltage surges on a.c. power circuits and to interrupt power follow current. Coverage includes arrester identification, arrester classification, standard voltage ratings, standard rated frequencies, switching impulse sparkover voltage, pressure relief, wet tests and acceptance tests. Also gives detailed definitions, table and annexes.
Committee |
SR 37
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
Standards | Relationship |
PN EN 60099-1 : 2002 | Identical |
UNE-EN 60099-1:1996 | Identical |
NBN EN 60099-1 : 1995 AMD 1 2000 | Identical |
IEC 60099-1:1991+AMD1:1999 CSV | Identical |
CEI EN 60099-1 : 2015 | Identical |
VDE 0675-1 : 2000 COR 1 2000 | Identical |
NF EN 60099-1 : 94 AMD 1 2000 | Identical |
NEN 10099-1 : 1994 | Identical |
NEN EN IEC 60099-1 : 1994 AMD 1 2000 | Identical |
SN EN 60099-1 : 1994 AMD 1 1999 | Identical |
I.S. EN 60099-1:1994 | Identical |
DIN EN 60099-1 : 2000 COR 1 2000 | Identical |
BS EN 60099-1:1994 | Identical |
BS EN 61076-3-001:2008 | Identical |
UNE-EN 50124-1:2017 | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment |
15/30298489 DC : 0 | BS EN 50124-1 - RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT |
DIN EN 45510-2-7:2003-12 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
I.S. EN 50123-4:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES |
CEI EN 61095 : 2010 | ELECTROMECHANICAL CONTACTORS FOR HOUSEHOLD AND SIMILAR PURPOSES |
UNE-EN 60099-4:2016 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
I.S. EN 50124-1:2017 | RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT |
EN 60730-1:2016 | Automatic electrical controls - Part 1: General requirements |
96/209091 DC : DRAFT JUN 1996 | EN 50124-2 RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 2: OVERVOLTAGES AND RELATED PROPERTIES |
BS EN 45510-2-7:2002 | Guide for the procurement of power station equipment. Electrical equipment Switchgear and controlgear |
BS EN 50123-2:2003 | Railway applications. Fixed installations. D.C. switchgear D.C. circuit breakers |
CEI EN 60664-1 : 2008 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 1: PRINCIPLES, REQUIREMENTS AND TESTS |
CEI UNI EN 45510-2-7 : 2006 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
PREN 50124-1 : DRAFT 2015 | RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT |
PD CLC/TR 50450:2006 | Resistibility requirements for equipment having (a) telecommunication port(s) |
EN 50123-7-2:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 7-2: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating current transducers and other current measuring devices |
CEI EN 61810-1 : 2016 | ELECTROMECHANICAL ELEMENTARY RELAYS - PART 1: GENERAL AND SAFETY REQUIREMENTS |
BS EN 50123-1:2003 | Railway applications. Fixed installations. D.C. switchgear General |
I.S. CLC/TR 50450:2006 | RESISTIBILITY REQUIREMENTS FOR EQUIPMENT HAVING (A) TELECOMMUNICATION PORT(S) |
EN 50124-1:2017 | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment |
I.S. EN 50123-7-2:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING CURRENT TRANSDUCERS AND OTHER CURRENT MEASURING DEVICES |
15/30298492 DC : 0 | BS EN 50124-2 - RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 2: OVERVOLTAGES AND RELATED PROTECTION |
BS EN 50123-7-1:2003 | Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Measurement, control and protection devices for specific use in d.c. traction systems. Application guide |
CEI EN 50123-1 : 2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 1: GENERAL |
I.S. EN 50123-5:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - SURGE ARRESTERS AND LOW-VOLTAGE LIMITERS FOR SPECIFIC USE IN D.C. SYSTEMS |
BS EN 50123-5:2003 | Railway applications. Fixed installations. D.C. switchgear Surge arresters and low-voltage limiters for specific use in d.c. systems |
BS EN 60934 : 2001 | CIRCUIT-BREAKERS FOR EQUIPMENT (CBE) |
I.S. EN 45510-2-7:2002 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
CLC/TR 50450:2006 | Resistibility requirements for equipment having (a) telecommunication port(s) |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
UNE-EN 60730-1:2013 | Automatic electrical controls for household and similar use - Part 1: General requirements |
EN 50123-5:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 5: Surge arresters and low-voltage limiters for specific use in d.c. systems |
DIN EN 50123-5 : 2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 5: SURGE ARRESTERS AND LOW-VOLTAGE LIMITERS FOR SPECIFIC USE IN D.C. SYSTEMS |
BS EN 50124-1:2017 | Railway applications. Insulation coordination Basic requirements. Clearances and creepage distances for all electrical and electronic equipment |
I.S. EN 50123-3:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES |
UNI CEI EN 45510-2-7 : 2011 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
PREN 50124-2 : DRAFT 2015 | RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 2: OVERVOLTAGES AND RELATED PROTECTION |
BS EN 61810-1:2015 | Electromechanical elementary relays General and safety requirements |
I.S. EN 50123-1:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - GENERAL |
EN 61810-1:2015/AC:2018-04 | ELECTROMECHANICAL ELEMENTARY RELAYS - PART 1: GENERAL AND SAFETY REQUIREMENTS (IEC 61810-1:2015/COR1:2018) |
I.S. EN 50123-2:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - D.C. CIRCUIT BREAKERS |
I.S. EN 60730-1:2016 | AUTOMATIC ELECTRICAL CONTROLS - PART 1: GENERAL REQUIREMENTS |
I.S. EN 50123-7-3:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING VOLTAGE TRANSDUCERS AND OTHER VOLTAGE MEASURING DEVICES |
I.S. EN 60664-1:2007 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 1: PRINCIPLES, REQUIREMENTS AND TESTS |
I.S. EN 60439-1:2000 | LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1 - TYPE TESTED AND PARTIALLY TYPE TESTED ASSEMBLIES |
BS EN 60439-1:1999 | Low-voltage switchgear and controlgear assemblies Type-tested and partially type-tested assemblies |
EN 45510-2-7:2002 | Guide for procurement of power station equipment - Part 2-7: Electrical equipment - Switchgear and controlgear |
EN 50123-7-3:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 7-3: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating voltage transducers and other voltage measuring devices |
CEI CLC/TR 50450 : 2006 | RESISTIBILITY REQUIREMENTS FOR EQUIPMENT HAVING (A) TELECOMMUNICATION PORT(S) |
BS EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems Principles, requirements and tests |
BS EN 50123-7-3:2003 | Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Isolating voltage transducers and other voltage measuring devices |
I.S. EN 61810-1:2015 | ELECTROMECHANICAL ELEMENTARY RELAYS - PART 1: GENERAL AND SAFETY REQUIREMENTS |
BS EN 61095:1993 | Specification for electromechanical contactors for household and similar purposes |
CEI EN 60071-2 : 1998 | INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDE |
I.S. EN 60934:2001 | CIRCUIT BREAKERS FOR EQUIPMENT (CBE) (IEC 60934:2000 (EQV)) |
I.S. EN 61095:2009 | ELECTROMECHANICAL CONTACTORS FOR HOUSEHOLD AND SIMILAR PURPOSES |
BS EN 50123-7-2:2003 | Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Isolating current transducers and other current measuring devices |
BS EN 60730-1:2011 | Automatic electrical controls for household and similar use General requirements |
EN 60934:2001/A2:2013 | CIRCUIT BREAKERS FOR EQUIPMENT (CBE) (IEC 60934:2000/A2:2013) |
EN 50123-1:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 1: General |
EN 50123-7-1:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 7-1: Measurement, control and protection devices for specific use in d.c. traction systems - Application guide |
EN 50123-4:2003/A1:2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES |
EN 50123-2:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 2: D.C. circuit breakers |
EN 60439-1:1999/A1:2004 | LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1 - TYPE TESTED AND PARTIALLY TYPE TESTED ASSEMBLIES |
EN 50123-3:2003/A1:2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES |
EN 61095:2009 | Electromechanical contactors for household and similar purposes |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.