EN 60079-29-2:2015
Current
The latest, up-to-date edition.
Explosive atmospheres - Part 29-2: Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen
08-05-2015
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Basic information on the properties, behaviour,
gases and vapours, and specific applications
of gas detection
5 Measuring principles
6 Selection of equipment
7 Behaviour of gas releases
8 Design and installation of fixed gas detection
systems
9 Use of portable and transportable flammable
gas detection equipment
10 Training of operational personnel
11 Maintenance, routine procedures and general
administrative control
Annex A (normative) - Measuring principles
Annex B (informative) - Environmental parameters
Annex C (informative) - Typical environmental and application
check-list for flammable gas detectors
(for both Group I and Group II equipment)
Annex D (informative) - Typical instrument maintenance
record for flammable gas Detectors
Annex E (informative) - Atmospheric visibility
Bibliography
Annex ZA (normative) - Normative references to international
Publications with their corresponding European
publications
NEW! IEC 60079-29-2:2015 is available as IEC Standards+ 60079-29-2:2015 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60079-29-2:2015 gives guidance on, and recommended practice for, the selection, installation, safe use and maintenance of electrically operated Group II equipment intended for use in industrial and commercial safety applications and Group I equipment in underground coal mines for the detection and measurement of flammable gases complying with the requirements of IEC 60079-29-1 or IEC 60079-29-4. This second edition cancels and replaces the first edition published in 2007. This edition constitutes a technical revision. Please refer to the Foreword of the document for a listing of the changes from the previous edition.
Keywords: gas detectors, flammable gases, vapours
Committee |
CLC/TC 31
|
DevelopmentNote |
Supersedes EN 50073. To be read in conjunction with EN 60079-0 and EN 60079-29-1. (02/2008)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Supersedes |
Standards | Relationship |
BS EN 60079-29-2:2015 | Identical |
NBN EN 60079-29-2 : 2015 | Identical |
VDE 0400-2 : 2015-12 | Identical |
PN EN 60079-29-2 : 2015 | Identical |
UNE-EN 60079-29-2:2016 | Identical |
I.S. EN 60079-29-2:2015 | Identical |
NEN EN IEC 60079-29-2 : 2015 | Identical |
CEI EN 60079-29-2 : 2016 | Identical |
DIN EN 60079-29-2 : 2015-12 | Identical |
NF EN 60079-29-2 : 2008 | Identical |
IEC 60079-29-2:2015 RLV | Identical |
UNE-EN 62282-3-300:2013 | Fuel cell technologies - Part 3-300: Stationary fuel cell power systems - Installation |
DIN EN 50402 : 2018 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF GAS DETECTION SYSTEMS |
I.S. EN 50402:2017 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF FIXED GAS DETECTION SYSTEMS |
VDE 0400-70 : 2018 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF GAS DETECTION SYSTEMS |
EN 378-3:2016 | Refrigerating systems and heat pumps - Safety and environmental requirements - Part 3: Installation site and personal protection |
BS EN 1755:2015 | Industrial Trucks. Safety requirements and verification. Supplementary requirements for operation in potentially explosive atmospheres |
DIN EN 1127-2:2002-07 | EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 2: BASIC CONCEPTS AND METHODOLOGY FOR MINING |
CLC/TR 60079-33:2015 | Explosive atmospheres - Part 33: Equipment protection by special protection 's' |
EN 62282-3-300:2012 | Fuel cell technologies - Part 3-300: Stationary fuel cell power systems - Installation |
OVE/ONORM EN 60079-29-1 : 2008 | EXPLOSIVE ATMOSPHERES - PART 29-1: GAS DETECTORS - PERFORMANCE REQUIREMENTS OF DETECTORS FOR FLAMMABLE GASES |
EN 60079-29-1:2016 | Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases |
BS EN 50402:2017 | Electrical apparatus for the detection and measurement of combustible or toxic gases or vapours or of oxygen. Requirements on the functional safety of gas detection systems |
BS EN 62282-3-300:2012 | Fuel cell technologies Stationary fuel cell power systems. Installation |
PREN 50402 : DRAFT 2013 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF FIXED GAS DETECTION SYSTEMS |
I.S. EN 60079-29-3:2014 | EXPLOSIVE ATMOSPHERES - PART 29-3: GAS DETECTORS - GUIDANCE ON FUNCTIONAL SAFETY OF FIXED GAS DETECTION SYSTEMS |
EN 50402:2017 | Electrical apparatus for the detection and measurement of combustible or toxic gases or vapours or of oxygen - Requirements on the functional safety of gas detection systems |
PREN 1539 : DRAFT 2012 | DRYERS AND OVENS, IN WHICH FLAMMABLE SUBSTANCES ARE RELEASED - SAFETY REQUIREMENTS |
UNE-EN 60079-29-1:2017 | Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases |
EN 50271:2010 | Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen - Requirements and tests for apparatus using software and/or digital technologies |
CEI EN 50271 : 2011 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE GASES, TOXIC GASES OR OXYGEN - REQUIREMENTS AND TESTS FOR APPARATUS USING SOFTWARE AND/OR DIGITAL TECHNOLOGIES |
CEI EN 50244 : 2017 | ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - GUIDE ON THE SELECTION, INSTALLATION, USE AND MAINTENANCE |
DIN EN 1755:2016-02 | Industrial Trucks - Safety requirements and verification - Supplementary requirements for operation in potentially explosive atmospheres |
I.S. EN 1127-2:2014 | EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 2: BASIC CONCEPTS AND METHODOLOGY FOR MINING |
I.S. EN 378-3:2016 | REFRIGERATING SYSTEMS AND HEAT PUMPS - SAFETY AND ENVIRONMENTAL REQUIREMENTS - PART 3: INSTALLATION SITE AND PERSONAL PROTECTION |
I.S. EN 1539:2015 | DRYERS AND OVENS, IN WHICH FLAMMABLE SUBSTANCES ARE RELEASED - SAFETY REQUIREMENTS |
I.S. EN 1755:2015 | INDUSTRIAL TRUCKS - SAFETY REQUIREMENTS AND VERIFICATION - SUPPLEMENTARY REQUIREMENTS FOR OPERATION IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
DIN EN 1539:2016-02 | DRYERS AND OVENS, IN WHICH FLAMMABLE SUBSTANCES ARE RELEASED - SAFETY REQUIREMENTS |
CEI EN 62282-3-300 : 2013 | FUEL CELL TECHNOLOGIES - PART 3-300: STATIONARY FUEL CELL POWER SYSTEMS - INSTALLATION |
13/30257895 DC : 0 | BS EN 1755 - SAFETY OF INDUSTRIAL TRUCKS - OPERATION IN POTENTIALLY EXPLOSIVE ATMOSPHERES - USE IN FLAMMABLE GAS, VAPOUR, MIST AND DUST |
14/30299502 DC : 0 | BS EN 45544-4:2014 - WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 4: GUIDE FOR SELECTION, INSTALLATION, USE AND MAINTENANCE |
S.R. CLC/TR 60079-33:2015 | EXPLOSIVE ATMOSPHERES - PART 33: EQUIPMENT PROTECTION BY SPECIAL PROTECTION 'S' |
12/30258755 DC : 0 | BS EN 1539 - DRYERS AND OVENS, IN WHICH FLAMMABLE SUBSTANCES ARE RELEASED - SAFETY REQUIREMENTS |
13/30260728 DC : 0 | BS EN 50402 - ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF FIXED GAS DETECTION SYSTEMS |
UNE-EN 50271:2011 | Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen - Requirements and tests for apparatus using software and/or digital technologies |
BS EN 50271:2010 | Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen. Requirements and tests for apparatus using software and/or digital technologies |
BS EN 60079-29-1:2007 | Explosive atmospheres Gas detectors. Performance requirements of detectors for flammable gases |
NF EN 50271 : 2010 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE GASES, TOXIC GASES OR OXYGEN - REQUIREMENTS AND TESTS FOR APPARATUS USING SOFTWARE AND/OR DIGITAL TECHNOLOGIES |
DIN EN 1127-2:2014-09 | EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 2: BASIC CONCEPTS AND METHODOLOGY FOR MINING |
UNE-EN 60079-14:2016 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
UNE-EN 1755:2016 | Industrial Trucks - Safety requirements and verification - Supplementary requirements for operation in potentially explosive atmospheres |
UNE-EN 378-3:2017 | Refrigerating systems and heat pumps - Safety and environmental requirements - Part 3: Installation site and personal protection |
BS EN 1539:2015 | Dryers and ovens, in which flammable substances are released. Safety requirements |
EN 45544-4:2016 | Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 4: Guide for selection, installation, use and maintenance |
UNI EN 1127-2 : 2014 | EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 2: BASIC CONCEPTS AND METHODOLOGY FOR MINING |
PREN 45544-4 : DRAFT 2014 | WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 4: GUIDE FOR SELECTION, INSTALLATION, USE AND MAINTENANCE |
BS EN 60079-29-3:2014 | Explosive atmospheres Gas detectors. Guidance on functional safety of fixed gas detection systems |
PREN 1755 : DRAFT 2013 | SAFETY OF INDUSTRIAL TRUCKS - OPERATION IN POTENTIALLY EXPLOSIVE ATMOSPHERES - USE IN FLAMMABLE GAS, VAPOUR, MIST AND DUST |
I.S. EN 50271:2010 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE GASES, TOXIC GASES OR OXYGEN - REQUIREMENTS AND TESTS FOR APPARATUS USING SOFTWARE AND/OR DIGITAL TECHNOLOGIES |
UNE-EN 1539:2010 | Dryers and ovens, in which flammable substances are released - Safety requirements |
BS EN 1127-2:2014 | Explosive atmospheres. Explosion prevention and protection Basic concepts and methodology for mining |
PD CLC/TR 60079-33:2015 | Explosive atmospheres Equipment protection by special protection \'s\' |
BS EN 378-3:2016 | Refrigerating systems and heat pumps. Safety and environmental requirements Installation site and personal protection |
EN 1755:2015 | Industrial Trucks - Safety requirements and verification - Supplementary requirements for operation in potentially explosive atmospheres |
EN 1539:2015 | Dryers and ovens, in which flammable substances are released - Safety requirements |
UNE-EN 50244:2001 | Electrical apparatus for the detection of combustible gases in domestic premises - Guide on the selection, installation, use and maintenance. |
BS EN 50244:2016 | Electrical apparatus for the detection of combustible gases in domestic premises. Guide on the selection, installation, use and maintenance |
I.S. EN 60079-29-1:2016 | EXPLOSIVE ATMOSPHERES - PART 29-1: GAS DETECTORS - PERFORMANCE REQUIREMENTS OF DETECTORS FOR FLAMMABLE GASES |
I.S. EN 62282-3-300:2012 | FUEL CELL TECHNOLOGIES - PART 3-300: STATIONARY FUEL CELL POWER SYSTEMS - INSTALLATION (IEC 62282-3-300:2012 (EQV)) |
I.S. EN 50244:2016 | ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - GUIDE ON THE SELECTION, INSTALLATION, USE AND MAINTENANCE |
BS EN 45544-4:2016 | Workplace atmospheres. Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours Guide for selection, installation, use and maintenance |
I.S. EN 45544-4:2016 | WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 4 - GUIDE FOR SELECTION, INSTALLATION, USE AND MAINTENANCE |
EN 60079-29-3:2014 | Explosive atmospheres - Part 29-3: Gas detectors - Guidance on functional safety of fixed gas detection systems |
EN 1127-2:2014 | Explosive atmospheres - Explosion prevention and protection - Part 2: Basic concepts and methodology for mining |
EN 50244:2016 | Electrical apparatus for the detection of combustible gases in domestic premises - Guide on the selection, installation, use and maintenance |
EN 45544-4 : 2016 | WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 4 - GUIDE FOR SELECTION, INSTALLATION, USE AND MAINTENANCE |
EN 60079-29-4:2010 | Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases |
EN 60079-10-1:2015 | Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres |
EN 60079-29-1:2016 | Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases |
IEC 60079-19:2010+AMD1:2015 CSV | Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation |
EN 60079-0:2012/A11:2013 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
IEC 60079-17:2013 | Explosive atmospheres - Part 17: Electrical installations inspection and maintenance |
EN 60079-19:2011/A1:2015 | EXPLOSIVE ATMOSPHERES - PART 19: EQUIPMENT REPAIR, OVERHAUL AND RECLAMATION (IEC 60079-19:2010) |
IEC 60079-29-3:2014 | Explosive atmospheres - Part 29-3: Gas detectors - Guidance on functional safety of fixed gas detection systems |
EN 60079-10-2:2015 | Explosive atmospheres - Part 10-2: Classification of areas - Explosive dust atmospheres |
IEC 60079-10-1:2015 | Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres |
IEC 60079-29-4:2009 | Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases |
IEC 60079-20-1:2010 | Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data |
IEC 60050-426:2008 | International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres |
EN 61326-1:2013 | Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
EN 60079-20-1:2010 | Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data |
EN 60079-14:2014/AC:2016 | EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016) |
NFPA 30 : 2018 | FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE |
IEC 61285:2015 | Industrial-process control - Safety of analyser houses |
EN 60079-17:2014 | Explosive atmospheres - Part 17: Electrical installations inspection and maintenance |
EN 60079-29-3:2014 | Explosive atmospheres - Part 29-3: Gas detectors - Guidance on functional safety of fixed gas detection systems |
EN 60079-13:2017 | Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" |
IEC 60079-13:2017 | Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" |
EN 61285:2015 | Industrial-process control - Safety of analyzer houses |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.