
EN 60076-1:2011
Current
The latest, up-to-date edition.

Power transformers - Part 1: General
04-11-2011
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Service conditions
5 Rating and general requirements
6 Requirements for transformers having a tapped winding
7 Connection phase displacement symbols
8 Rating plates
9 Safety, environmental and other requirements
10 Tolerances
11 Tests
12 Electromagnetic compatibility (EMC)
13 High frequency switching transients
Annex A (informative) - Check list of information to be
provided with enquiry and order
Annex B (informative) - Examples of specifications for
transformers with tappings
Annex C (informative) - Specification of short-circuit
impedance by boundaries
Annex D (informative) - Examples of three-phase transformer
connections
Annex E (normative) - Temperature correction of load loss
Annex F (informative) - Facilities for future fitting of
condition monitoring systems to transformers
Annex G (informative) - Environmental and safety considerations
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
IEC 60076-1:2011 applies to three-phase and single-phase power transformers (including auto-transformers) with the exception of certain categories of small and special transformers. For those categories of power transformers and reactors which have their own IEC standards, this part is applicable only to the extent in which it is specifically called up by cross-reference in the other standard. This new edition includes the following significant technical additions with respect to the previous one:- definition of harmonic content;- subclause on transport;- functional method of specification;- connection symbols for single phase transformers;- safety and environmental requirements;- requirements for liquid preservation systems;- clause on DC currents;- vacuum, pressure and leak tests on tanks;- facilities for condition monitoring and environmental and safety considerations.
Committee |
CLC/TC 14
|
DevelopmentNote |
Supersedes HD 398.1 and HD 398.4. (07/2004)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Supersedes |
Standards | Relationship |
VDE 0532-76-1 : 2012 | Identical |
CEI EN 60076-1 : 2015 | Identical |
PN EN 60076-1 : 2011 | Identical |
BS EN 60076-1:2011 | Identical |
SN EN 60076-1 : 1997 AMD 12 2002 | Identical |
IEC 60076-1:2011 | Identical |
NBN EN 60076-1 : 2011 | Identical |
VDE 0532-1 : 1982 | Corresponds |
NEN EN IEC 60076-1 : 2011 | Identical |
VDE 0532-101 : 97 AMD 1 2001 | Identical |
DIN EN 60076-1 : 2012 | Identical |
NF EN 60076-1 : 2012 | Identical |
UNE-EN 60076-1:2013 | Identical |
I.S. EN 60076-1:2011 | Identical |
BS EN IEC 61190-1-3:2018 | Identical |
BS EN 60076-11:2004 | Power transformers Dry-type transformers |
BS EN 60076-13:2006 | Power transformers Self-protected liquid-filled transformers |
BS EN 60143-4:2010 | Series capacitors for power systems Thyristors controlled series capacitors |
BS EN 50329 : 2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS |
I.S. EN 60726:2003 | DRY-TYPE POWER TRANSFORMERS |
CEI EN 60076-14 : 2014 | POWER TRANSFORMERS - PART 14: LIQUID-IMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS |
CEI EN 60076-11 : 2006 | POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS |
I.S. EN 60076-3:2013 | POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR |
BS EN 50216-7:2002 | Power transformers and reactor fittings Electric pumps for transformer oil |
UNE-EN 50541-1:2012 | Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements |
UNE-EN 61378-1:2012 | Convertor transformers -- Part 1: Transformers for industrial applications |
BS EN 60076-6:2008 | Power transformers Reactors |
I.S. EN 60143-4:2010 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS |
CEI EN 50216-7 : 2002 | POWER TRANSFORMER AND REACTOR FITTINGS - PART 7: ELECTRIC PUMPS FOR TRANSFORMER OIL |
CEI EN 61378-2 : 2002 | CONVERTOR TRANSFORMERS - PART 2: TRANSFORMERS FOR HVDC APPLICATIONS |
I.S. EN 60076-11:2004 | POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS |
I.S. EN 62271-212:2017 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 212: COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATION (CEADS) |
I.S. EN 60076-14:2013 | POWER TRANSFORMERS - PART 14: LIQUIDIMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS (IEC 60076-14:2013 (EQV)) |
I.S. EN 61248-1:1998 | TRANSFORMERS AND INDUCTORS FOR USE IN ELECTRONIC AND TELECOMMUNICATION EQUIPMENT - PART 1: GENERIC SPECIFICATION |
UNE-EN 62271-212:2017 | High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS) |
BS EN 61558-1 : 2005 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
EN 50216-2 : 2002 AMD 1 2002 | POWER TRANSFORMER AND REACTOR FITTINGS - PART 2: GAS AND OIL ACTUATED RELAY FOR LIQUID IMMERSED TRANSFORMERS AND REACTORS WITH CONSERVATOR |
EN 50216-1:2002 | Power transformer and reactor fittings - Part 1: General |
EN 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
EN 61558-1:2005/A1:2009 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
EN 60076-11:2004 | Power transformers - Part 11: Dry-type transformers |
EN 61968-11:2013 | Application integration at electric utilities - System interfaces for distribution management - Part 11: Common information model (CIM) extensions for distribution |
EN 62271-212:2017 | High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS) |
EN 50541-1:2011 | Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements |
EN 62271-202:2014/AC:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION (IEC 62271-202:2014) |
EN 61378-1:2011 | Convertor transformers - Part 1: Transformers for industrial applications |
EN 60726:2003 | Dry-type power transformers |
08/30186443 DC : DRAFT SEP 2008 | BS EN 15869-3 - INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE-PHASE CURRENT 400 V, UP TO 32 A, 50 HZ - PART 3: ON-BOARD UNIT, SAFETY REQUIREMENTS |
BS EN 60076-2:2011 | Power transformers Temperature rise for liquid-immersed transformers |
CEI EN 61968-11 : 2013 | APPLICATION INTEGRATION AT ELECTRIC UTILITIES - SYSTEM INTERFACES FOR DISTRIBUTION MANAGEMENT - PART 11: COMMON INFORMATION MODEL (CIM) EXTENSIONS FOR DISTRIBUTION |
BS EN 50588-1:2017 | Medium power transformers 50 Hz, with highest voltage for equipment not exceeding 36 kV General requirements |
BS EN 50216-2:2002 | Power transformers and reactor fittings Gas and oil actuated relay for liquid immersed transformers and reactors with conservator |
BS EN 60076-14:2013 | Power transformers Liquid-immersed power transformers using high-temperature insulation materials |
CEI EN 60076-5 : 2007 | POWER TRANSFORMERS - PART 5: ABILITY TO WITHSTAND SHORT CIRCUIT |
BS EN 50541-1:2011 | Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3150 kVA, with highest voltage for equipment not exceeding 36 kV General requirements |
EN 61643-351:2017 | Components for low-voltage surge protective devices - Part 351: Performance requirements and test methods for telecommunications and signalling network surge isolation transformers (SIT) |
UNE-EN 60076-14:2014 | Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials |
CEI EN 60076-16 : 2012 | POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATIONS |
I.S. EN 60076-13:2006 | POWER TRANSFORMERS - PART 13: SELF-PROTECTED LIQUID-FILLED TRANSFORMERS |
CEI EN 50216-1 : 2002 | POWER TRANSFORMER AND REACTOR FITTINGS - PART 1: GENERAL |
I.S. EN 50299:2004 | OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT U[M] FROM 72.5 KV TO 550 KV |
I.S. EN 62271-202:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION |
I.S. EN 60076-5:2006 | POWER TRANSFORMERS - PART 5: ABILITY TO WITHSTAND SHORT-CIRCUIT |
UNI EN 15869-3 : 2010 | INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE-PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 3: ON-BOARD UNIT, SAFETY REQUIREMENTS |
DIN EN 15869-3:2010-06 | INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 3: ON-BOARD UNIT, SAFETY REQUIREMENTS |
CEI EN 61378-1 : 2012 | CONVERTOR TRANSFORMERS - PART 1: TRANSFORMERS FOR INDUSTRIAL APPLICATIONS |
CEI EN 60143-4 : 2012 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS |
I.S. EN 61803:1999 | DETERMINATION OF POWER LOSSES IN HIGH-VOLTAGE DIRECT CURRENT (HVDC) CONVERTER STATIONS WITH LINE COMMUTATED CONVERTERS |
I.S. EN 50216-12:2011 | POWER TRANSFORMER AND REACTOR FITTINGS - PART 12: FANS |
EN 50216-12:2011 | Power transformer and reactor fittings - Part 12: Fans |
VDE 0532-42 : 2001 | CONVERTOR TRANSFORMERS - PART 2: TRANSFORMERS FOR HVDC APPLICATIONS |
CEI EN 60076-2 : 2015 | POWER TRANSFORMERS - PART 2: TEMPERATURE RISE FOR LIQUID-IMMERSED TRANSFORMERS |
CEI EN 61803 : 2011 | DETERMINATION OF POWER LOSSES IN HIGH-VOLTAGE DIRECT CURRENT (HVDC) CONVERTER STATIONS |
BS EN 61803 : 1999 | DETERMINATION OF POWER LOSSES IN HIGH-VOLTAGE DIRECT CURRENT (HVDC) CONVERTER STATIONS WITH LINE-COMMUTATED CONVERTERS (IEC 61803:1999) |
NF EN 50541-1 : 2011 | THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 KVA TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS |
BS EN 60214-1:2014 | Tap-changers Performance requirements and test methods |
CEI EN 50541-1 : 2011 | THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 KVA TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS |
I.S. EN 50588-1:2017 | MEDIUM POWER TRANSFORMERS 50 HZ, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS |
BS EN 50327:2003 | Railway applications. Fixed installations. Harmonisation of the rated values for converter groups and tests on converter groups |
CEI EN 60310 : 2016 | RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK |
BS EN 60143-2:2013 | Series capacitors for power systems Protective equipment for series capacitor banks |
CEI EN 60143-2 : 2014 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 2: PROTECTIVE EQUIPMENT FOR SERIES CAPACITOR BANKS |
I.S. EN 60310:2016 | RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK |
I.S. EN 60076-19:2015 | POWER TRANSFORMERS - PART 19: RULES FOR THE DETERMINATION OF UNCERTAINTIES IN THE MEASUREMENT OF THE LOSSES ON POWER TRANSFORMERS AND REACTORS |
BS EN 15869-3:2010 | Inland navigation vessels. Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz On-board unit, safety requirements |
CEI EN 60076-10 : 2002 | POWER TRANSFORMERS - PART 10: DETERMINATION OF SOUND LEVELS |
I.S. EN 50541-1:2011 | THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 KVA TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS |
PREN 50541-1 : DRAFT 2009 | THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR DRY TYPE TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV |
UNE-EN 60076-19:2016 | Power transformers - Part 19: Rules for the determination of uncertainties in the measurement of the losses on power transformers and reactors |
I.S. EN 60076-6:2008 | POWER TRANSFORMERS - PART 6: REACTORS |
I.S. EN 60076-10:2016 | POWER TRANSFORMERS - PART 10: DETERMINATION OF SOUND LEVELS |
UNE-EN 62271-202:2015 | High-voltage switchgear and controlgear - Part 202: High-voltage/low-voltage prefabricated substation |
EN 50532:2010 | Compact Equipment Assembly for Distribution Substations (CEADS) |
09/30211604 DC : 0 | BS EN 50541-1 - THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR DRY TYPE TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV |
BS EN 61968-11:2013 | Application integration at electric utilities. System interfaces for distribution management Common information model (CIM) extensions for distribution |
I.S. EN 50532:2010 | COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATIONS (CEADS) |
BS EN 50216-1:2002 | Power transformers and reactor fittings General |
I.S. EN 60143-2:2013 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 2: PROTECTIVE EQUIPMENT FOR SERIES CAPACITOR BANKS (IEC 60143-2:2012 (EQV)) |
BS EN 60076-10:2016 | Power transformers Determination of sound levels |
BS EN 60076-16:2011 | Power transformers Transformers for wind turbines applications |
BS EN 61378-1:2011 | Convertor transformers Transformers for industrial applications |
EN IEC/IEEE 65700 : 2018 | BUSHINGS FOR DC APPLICATION (IEC/IEEE 65700-19-03:2014) |
UNE-EN 60076-16:2012 | Power transformers - Part 16: Transformers for wind turbines applications |
BS EN 60726:2003 | Dry-type power transformers |
CEI EN 60076-3 : 2015 | POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR |
EN 50588-1:2017 | Medium power transformers 50 Hz, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements |
I.S. EN 60076-2:2011 | POWER TRANSFORMERS - PART 2: TEMPERATURE RISE FOR LIQUID-IMMERSED TRANSFORMERS |
BS EN 60310:2016 | Railway applications. Traction transformers and inductors on board rolling stock |
I.S. EN 61968-11:2013 | APPLICATION INTEGRATION AT ELECTRIC UTILITIES - SYSTEM INTERFACES FOR DISTRIBUTION MANAGEMENT - PART 11: COMMON INFORMATION MODEL (CIM) EXTENSIONS FOR DISTRIBUTION (IEC 61968-11:2013 (EQV)) |
I.S. EN 15869-3:2010 | INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 3: ON-BOARD UNIT, SAFETY REQUIREMENTS |
I.S. EN 50216-1:2002 | POWER TRANSFORMER AND REACTOR FITTINGS - PART 1: GENERAL |
CEI EN 60076-6 : 2015 | POWER TRANSFORMERS - PART 6: REACTORS |
I.S. EN 61558-1:2006 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
EN 61803:1999/A2:2016 | DETERMINATION OF POWER LOSSES IN HIGH-VOLTAGE DIRECT CURRENT (HVDC) CONVERTER STATIONS WITH LINE COMMUTATED CONVERTERS (IEC 61803:1999/A2:2016) |
BS EN 62271-212:2017 | High-voltage switchgear and controlgear Compact Equipment Assembly for Distribution Substation (CEADS) |
BS EN 50532:2010 | Compact equipment assembly for distribution substations (CEADS) |
09/30202403 DC : 0 | BS EN 50532 - COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATIONS (CEADS) |
UNE-EN 50532:2011 | Compact Equipment Assembly for Distribution Substations (CEADS) |
UNE-EN 60076-2:2013 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
EN 60076-16:2011 | Power transformers - Part 16: Transformers for wind turbines applications |
EN 15869-3:2010 | Inland navigation vessels - Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz - Part 3: On-board unit, safety requirements |
CEI EN 60076-13 : 2007 | POWER TRANSFORMERS - PART 13: SELF PROTECTED LIQUID FILLED TRANSFORMERS |
I.S. EN 50216-2:2002 | POWER TRANSFORMER AND REACTOR FITTINGS - PART 2: GAS AND OIL ACTUATED RELAY FOR LIQUID IMMERSED TRANSFORMERS AND REACTORS WITH CONSERVATOR |
I.S. EN 50327:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS |
BS EN 60076-5:2006 | Power transformers Ability to withstand short-circuit |
CEI CLC/TR 50462 : 2009 | RULES FOR THE DETERMINATION OF UNCERTAINTIES IN THE MEASUREMENT OF THE LOSSES ON POWER TRANSFORMERS AND REACTORS |
BS EN 61800-4:2003 | Adjustable speed electrical power drive systems General requirements. Rating specifications for a.c. power drive systems above 1000 V a.c. and not exceeding 35 kV |
BS EN 60076-19:2015 | Power transformers Rules for the determination of uncertainties in the measurement of the losses on power transformers and reactors |
BS EN 61248-1:1997 | Transformers and inductors for use in electronic and telecommunication equipment Generic specification |
BS EN 61643-351:2017 | Components for low-voltage surge protective devices Performance requirements and test methods for telecommunications and signalling network surge isolation transformers (SIT) |
13/30281716 DC : 0 | BS EN 50299-2 - OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT U[M] FROM 72,5 KV TO 550 KV - PART 2: DRY-TYPE CABLE TERMINATIONS |
CLC/TR 50462:2008 | Rules for the determination of uncertainties in the measurement of the losses on power transformers and reactors |
BS EN 60076-3 : 2013 | POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR |
UNE-EN 15869-3:2011 | Inland navigation vessels - Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz - Part 3: On-board unit, safety requirements |
NF EN 15869-3 : 2010 | INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 3: ON-BOARD UNIT, SAFETY REQUIREMENTS |
I.S. EN 60076-16:2011 | POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATIONS (IEC 60076-16:2011) |
UNE-EN 60076-10:2017 | Power transformers - Part 10: Determination of sound levels |
I.S. EN 50329:2007 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS |
I.S. EN IEC/IEEE 65700:2018 | BUSHINGS FOR DC APPLICATION |
I.S. EN 61378-1:2011 | CONVERTOR TRANSFORMERS - PART 1: TRANSFORMERS FOR INDUSTRIAL APPLICATIONS (IEC 61378-1:2011) |
CEI EN 61800-4 : 2003 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 4: GENERAL REQUIREMENTS - RATING SPECIFICATIONS FOR A/C/ POWER DRIVE SYSTEMS ABOVE 1000 V A.C. AND NOT EXCEEDING 35 KV |
I.S. EN 61800-4:2003 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 4: GENERAL REQUIREMENTS - RATING SPECIFICATIONS FOR A.C. POWER DRIVE SYSTEMS ABOVE 1000 V A.C. AND NOT EXCEEDING 35 KV |
S.R. CLC/TR 50462:2008 | RULES FOR THE DETERMINATION OF UNCERTAINTIES IN THE MEASUREMENT OF THE LOSSES ON POWER TRANSFORMERS AND REACTORS |
BS EN 62271-202:2014 | High-voltage switchgear and controlgear High-voltage/low-voltage prefabricated substation |
EN 50327 : 2003 AMD 1 2005 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS |
EN 50329:2003/A1:2010 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS |
EN 60076-6:2008 | Power transformers - Part 6: Reactors |
EN 60076-13:2006 | Power transformers - Part 13: Self-protected liquid-filled transformers |
EN 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
EN 60076-19:2015 | Power transformers - Part 19: Rules for the determination of uncertainties in the measurement of the losses on power transformers and reactors |
EN 61248-1 : 1997 | Transformers and inductors for use in electronic and telecommunication equipment - Part 1: Generic specification |
EN 61800-4:2003 | Adjustable speed electrical power drive systems - Part 4: General requirements - Rating specifications for a.c. power drive systems above 1 000 V a.c. and not exceeding 35 kV |
EN 60143-4:2010 | Series capacitors for power systems - Part 4: Thyristor controlled series capacitors |
EN 60143-2:2013 | Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks |
EN 60076-5:2006 | Power transformers - Part 5: Ability to withstand short-circuit |
EN 60214-1:2014 | Tap-changers - Part 1: Performance requirements and test methods |
DIN EN 61558-2-17 : 1998 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLY UNITS AND SIMILAR - PART 2-17: PARTICULAR REQUIREMENTS FOR TRANSFORMERS FOR SWITCH MODE POWER SUPPLIES |
EN 60310:2016/AC:2018-03 | RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK (IEC 60310:2016/COR1:2018) |
EN 60076-14:2013 | Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials |
EN 60076-3:2013/A1:2018 | POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR (IEC 60076-3:2013/A1:2018) |
IEC 60076-15:2015 | Power transformers - Part 15: Gas-filled power transformers |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60076-7:2005 | Power transformers - Part 7: Loading guide for oil-immersed power transformers |
EN 60214-1:2014 | Tap-changers - Part 1: Performance requirements and test methods |
IEC TR 60616:1978 | Terminal and tapping markings for power transformers |
EN 60076-5:2006 | Power transformers - Part 5: Ability to withstand short-circuit |
IEC 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
EN 60076-11:2004 | Power transformers - Part 11: Dry-type transformers |
IEC 60076-5:2006 | Power transformers - Part 5: Ability to withstand short circuit |
ISO 3:1973 | Preferred numbers — Series of preferred numbers |
IEEE C57.12.00-2015 | IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers |
IEC 60068-3-3:1991 | Environmental testing - Part 3-3: Guidance - Seismic test methods for equipments |
IEC 60076-4:1976 | Power transformers - Part 4: Tappings and connections |
IEC 60076-8:1997 | Power transformers - Part 8: Application guide |
IEEE C57.12.90-2010 | IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers |
IEC 60076-12:2008 | Power transformers - Part 12: Loading guide for dry-type power transformers |
EN 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
IEC 60296:2012 RLV | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
IEC 60076-3:2013 | Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air |
IEC 60050-421:1990 | International Electrotechnical Vocabulary (IEV) - Part 421: Power transformers and reactors |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN 60296:2012 | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60137:2017 | Insulated bushings for alternating voltages above 1000 V |
IEC 60076-6:2007 | Power transformers - Part 6: Reactors |
IEC 62032:2012 | Guide for the Application, Specification and Testing of Phase-Shifting Transformers |
ISO 14001:2015 | Environmental management systems — Requirements with guidance for use |
IEEE C57.142 : 2010 | GUIDE TO DESCRIBE THE OCCURRENCE AND MITIGATION OF SWITCHING TRANSIENTS INDUCED BY TRANSFORMERS, SWITCHING DEVICE, AND SYSTEM INTERACTION |
IEC 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
ISO 9001:2015 | Quality management systems — Requirements |
ISO 2178:2016 | Non-magnetic coatings on magnetic substrates — Measurement of coating thickness — Magnetic method |
IEC 61378-2:2001 | Convertor transformers - Part 2: Transformers for HVDC applications |
IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
IEC TS 60076-14:2009 | Power transformers - Part 14: Design and application of liquid-immersed power transformers using high-temperature insulation materials |
IEC 60076-13:2006 | Power transformers - Part 13: Self-protected liquid-filled transformers |
ISO 2409:2013 | Paints and varnishes Cross-cut test |
EN 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
EN 60721-3-4:1995/A1:1997 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 4: STATIONARY USE AT NON-WEATHER-PROTECTED LOCATIONS |
IEC 60076-10-1:2016 | Power transformers - Part 10-1: Determination of sound levels - Application guide |
IEC 60076-16:2011 | Power transformers - Part 16: Transformers for wind turbine applications |
IEC 61378-1:2011 | Converter transformers - Part 1: Transformers for industrial applications |
IEC 60214-1:2014 | Tap-changers - Part 1: Performance requirements and test methods |
IEC 60310:2016 | Railway applications - Traction transformers and inductors on board rolling stock |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.
Logging out.