EN 60044-7:2000
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Instrument transformers - Part 7: Electronic voltage transformers
01-12-2016
24-01-2000
1 General
1.1 Scope
1.2 Normative references
1.3 General block diagram of electronic voltage
transformers
2 Definitions
2.1 General definitions
2.2 Additional definitions for single-phase
electronic protective voltage transformers
2.3 Index of symbols
3 General requirements
3.1 General
3.2 Information to be given for enquiries,
tenders and orders
4 Normal and special service conditions
4.1 Normal service conditions
4.2 Special service conditions
4.3 Earthing system
5 Ratings
5.1 Standard values of rated voltages
5.2 Standard values of rated output
5.3 Standard values of rated voltage factor
5.4 Standard values of rated auxiliary power
supply voltage
5.5 Standard reference values of other influencing
parameters
6 Design requirements
6.1 Insulation requirements for primary voltage
sensor
6.2 Insulation requirements for low-voltage
components
6.3 Short-circuit withstand capability
6.4 Limits of temperature rise
6.5 Radio interference voltage requirements
6.6 Transmitted overvoltage requirements
6.7 Electromagnetic compatibility requirements
6.8 Reliability
6.9 Abnormal conditions withstand capability
6.10 Abnormal conditions signalling
6.11 Mechanical requirements
6.12 Earthing terminals
7 Classification of tests
7.1 Type tests
7.2 Routine tests
7.3 Special tests
8 Type tests
8.1 Impulse test on primary voltage terminals
8.2 Wet test for outdoor type electronic voltage
transformers
8.3 Tests for accuracy
8.4 Test for abnormal conditions withstand capability
8.5 Radio interference voltage test
8.6 Transmitted overvoltage test
8.7 Electromagnetic compatibility tests
8.8 Impulse voltage withstand test for low-voltage
components
8.9 Transient performance tests
9 Routine tests
9.1 Verification of terminal markings
9.2 Power-frequency withstand tests on primary
voltage terminals and partial discharge
measurement
9.3 Power-frequency voltage withstand test for
low-voltage components
9.4 Tests for accuracy
10 Special tests
10.1 Chopped lightning-impulse test on primary voltage
terminals
10.2 Measurement of capacitance and dielectric
dissipation factor
10.3 Mechanical strength tests
11 Markings
11.1 Rating plate markings
11.2 Terminal markings
12 Accuracy requirements for single-phase electronic
measuring voltage transformers
12.1 General requirements
12.2 Maintenance requirement
12.3 Accuracy class designation for electronic
measuring voltage transformers
12.4 Standard accuracy classes for electronic
measuring voltage transformers
12.5 Limits of voltage error and phase displacement
for electronic measuring voltage transformers
13 Additional requirements for single-phase electronic
protective voltage transformers
13.1 General requirements
13.2 Maintenance requirements
13.3 Accuracy class designation for electronic
protective voltage transformers
13.4 Standard accuracy classes for electronic
protective voltage transformers
13.5 Limits of voltage error and phase displacement
for electronic protective voltage transformers
13.6 Transient performance requirements
Annex A (normative) Burdens for the transient response test
Annex B (informative) Technical information for electronic
voltage transformers
Annex C (informative) Bibliography
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Applies to newly manufactured electronic voltage transformers with analogue output, for use with electrical measuring instruments and electrical protective devices at frequencies from 15 Hz to 100 Hz. The standard covers optical arrangements with electronic components. Three-phase voltage transformers are not included, but some of the requirements apply.
Committee |
CLC/TC 38
|
DevelopmentNote |
Superseded by EN 61869-6 but remains current and will be withdrawn until all the relevant parts of EN 61869 series will be published. (01/2017)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
PN EN 60044-7 : 2003 | Identical |
I.S. EN 60044-7:2000 | Identical |
NF EN 60044-7 : 2001 | Identical |
BS EN 60044-7:2000 | Identical |
NEN EN IEC 60044-7 : 2000 | Identical |
DIN EN 60044-7 : 2000 | Identical |
IEC 60044-7:1999 | Identical |
NBN EN 60044-7 : 2001 | Identical |
VDE 0414-44-7 : 2000 | Identical |
UNE-EN 60044-7:2001 | Identical |
SN EN 60044-7 : 2000 | Identical |
CEI EN 60044-7 : 2001 | Identical |
UNE-EN 62271-205:2011 | High-voltage switchgear and controlgear -- Part 205: Compact switchgear assemblies for operation at rated voltages above 52 kV |
I.S. EN 50327:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS |
BS EN 60255-1:2010 | Measuring relays and protection equipment Common requirements |
I.S. EN 60044-8:2002 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
EN 62271-205:2008/corrigendum:2008 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
EN 61869-6:2016 | Instrument transformers - Part 6: Additional general requirements for low-power instrument transformers |
EN 61850-9-1:2003 | Communication networks and systems in substations - Part 9-1: Specific Communication Service Mapping (SCSM) - Sampled values over serial unidirectional multidrop point to point link |
UNE-EN 61557-12:2010 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures -- Part 12: Performance measuring and monitoring devices (PMD) |
BS EN 60044-8:2002 | Instrument transformers Electronic current transformers |
I.S. EN 62689-1:2016 | CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS |
S.R. CLC/TS 50549-2:2015 | REQUIREMENTS FOR GENERATING PLANTS TO BE CONNECTED IN PARALLEL WITH DISTRIBUTION NETWORKS - PART 2: CONNECTION TO A MV DISTRIBUTION NETWORK |
BS EN 50327:2003 | Railway applications. Fixed installations. Harmonisation of the rated values for converter groups and tests on converter groups |
CEI EN 61850-9-1 : 2015 | COMMUNICATION NETWORKS AND SYSTEMS IN SUBSTATIONS - PART 9-1: SPECIFIC COMMUNICATION SYSTEM MAPPINGS (SCSM) - SAMPLED VALUES OVER SERIAL UNIDIRECTIONAL MULTIDROP POINT TO POINT LINK |
I.S. EN 62271-205:2008 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
CEI EN 60044-8 : 2004 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRASFORMERS |
BS EN 61850-9-1:2003 | Communication networks and systems in substations. Specific communication service mapping (SCSM) Sampled values over serial unidirectional multidrop point to point link |
EN 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements |
CLC/TS 50549-2:2015 | Requirements for generating plants to be connected in parallel with distribution networks - Part 2: Connection to a MV distribution network |
I.S. EN 61850-9-1:2003 | COMMUNICATION NETWORKS AND SYSTEMS IN SUBSTATIONS - PART 9-1: SPECIFIC COMMUNICATION SERVICE MAPPING (SCSM) - SAMPLED VALUES OVER SERIAL UNIDIRECTIONAL MULTIDROP POINT TO POINT LINK |
CEI EN 60255-1 : 2011 | MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 1: COMMON REQUIREMENTS |
CEI EN 62271-205 : 2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
UNE-EN 60255-1:2010 | Measuring relays and protection equipment -- Part 1: Common requirements |
BS EN 61869-6:2016 | Instrument transformers Additional general requirements for low-power instrument transformers |
BS EN 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes General principles and requirements |
BS EN 62271-205:2008 | High-voltage switchgear and controlgear Compact switchgear assemblies for rated voltages above 52 kV |
I.S. EN 60255-1:2010 | MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 1: COMMON REQUIREMENTS |
EN 50327 : 2003 AMD 1 2005 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS |
EN 60255-1:2010 | Measuring relays and protection equipment - Part 1: Common requirements |
EN 60044-8:2002 | Instrument transformers - Part 8: Electronic current transformers |
IEC 60255-22-1:2007 | Measuring relays and protection equipment - Part 22-1: Electrical disturbance tests - 1 MHz burst immunity tests |
IEC 60038:2009 | IEC standard voltages |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60050-601:1985 | International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General |
IEC 60044-2:1997+AMD1:2000+AMD2:2002 CSV | Instrument transformers - Part 2 : Inductive voltage transformers |
IEC 60255-11:2008 | Measuring relays and protection equipment - Part 11: Voltage dips, short interruptions, variations and ripple on auxiliary power supply port |
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV | Common specifications for high-voltage switchgear and controlgear standards |
EN 50081-2:1993 | Electromagnetic compatibility - Generic emission standard - Part 2: Industrial environment |
IEC 60617-1:1985 | Graphical symbols for diagrams. Part 1: General information, general index. Cross-reference tables |
IEC 60255-5:2000 | Electrical Relays - Part 5: Insulation coordination for measuring relays and protection equipment - Requirements and tests |
IEC 60255-6:1988 | Electrical relays - Part 6: Measuring relays and protection equipment |
IEC 60050-321:1986 | International Electrotechnical Vocabulary (IEV) - Part 321: Instrument transformers |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 60186:1987 | Voltage transformers |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.