EN 54-31:2014+A1:2016
Current
The latest, up-to-date edition.
Fire detection and fire alarm systems - Part 31: Multi-sensor fire detectors - Point detectors using a combination of smoke, carbon monoxide and optionally heat sensors
27-04-2016
European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Testing, assessment and sampling methods
6 Classification and designation
7 Marking, Labelling and Packaging
Annex A (normative) - Smoke tunnel for smoke response
values
Annex B (normative) - Test aerosol for smoke response
value measurements
Annex C (normative) - Smoke measuring instruments
Annex D (normative) - Gas test chamber for CO response
threshold value and crosssensitivity to chemical agents
Annex E (normative) - Heat tunnel for heat response value
Annex F (normative) - Measuring instruments for CO
Annex G (informative) - Establishing exposure levels of
chemical agents
Annex H (normative) - Apparatus for dazzling test
Annex I (informative) - Apparatus for impact test
Annex J (normative) - Fire test room
Annex K (normative) - Open wood fire (TF1)
Annex L (normative) - Smouldering (pyrolysis) wood fire (TF2)
Annex M (normative) - Glowing smouldering cotton fire (TF3)
Annex N (normative) - Open plastics (polyurethane) fire (TF4)
Annex O (normative) - Liquid (heptane) fire (TF5)
Annex P (normative) - Low temperature black smoke
(decalene) liquid fire (TF8)
Annex Q (informative) - Information concerning the
construction of the smoke tunnel
Annex R (informative) - Information concerning the
construction of the gas test chamber
Annex S (informative) - Construction of the heat tunnel
Annex T (informative) - Information concerning test
procedures and requirements for response to slowly
developing fires, aging and contamination
Annex U (informative) - Information concerning the
construction of the measuring ionization chamber
Bibliography
This European Standard specifies requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection and fire alarm systems installed in and around buildings (see EN 54 1:2011), incorporating in one mechanical enclosure at least one optical or ionization smoke sensor and at least one carbon monoxide (CO) sensor and optionally one or more heat sensors, utilizing the combination of the detected phenomena. This European Standard covers only modes of operation, where at least the signals of both smoke and carbon monoxide sensors are continuously evaluated.This European Standard provides for the assessment and verification of constancy of performance (AVCP) of point detectors using a combination of smoke, carbon monoxide and optionally heat sensors to this EN.Point detectors using a combination of smoke, carbon monoxide and optionally heat sensors, which are having special characteristics suitable for the detection of specific fire risks are not covered by this European Standard. The performance requirements for any additional functions are beyond the scope of this standard (e.g. additional features or enhanced functionality for which this European Standard does not define a test or assessment method).
Committee |
CEN/TC 72
|
DevelopmentNote |
Supersedes PREN 54-31. (12/2014) 2014 Edition Re-Issued in April 2016 & incorporates AMD 1 2016. (05/2016)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
UNE-EN 54-3:2016+A1:2019 | Identical |
PN EN 54-31 : 2015 + A1 2016 | Identical |
NS EN 54-31 : 2014 + A1 2016 | Identical |
SN EN 54-31+A1:2016 | Identical |
DIN EN 54-31:2015-05 | Identical |
UNI EN 54-31 : 2016 | Identical |
NF EN 54-31 : 2015 + A1 2016 | Identical |
NEN EN 54-31 : 2015 + A1 2016 | Identical |
BS EN 54-31 : 2014 | Identical |
NBN EN 54-31 : 2015 + A1 2016 | Identical |
DIN EN 54-31:2016-12 | Identical |
UNE-EN 54-31:2014+A1:2019 | Identical |
DIN EN 54-31 E : 2016 | Identical |
I.S. EN 54-31:2014 | Identical |
BS EN 54-31:2014+A1:2016 | Identical |
11/30249544 DC : 0 | BS EN 54-14 - FIRE DETECTION AND FIRE ALARM SYSTEMS - GUIDELINES FOR PLANNING, DESIGN, INSTALLATION, COMMISSIONING, USE AND MAINTENANCE |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
ISO 209:2007 | Aluminium and aluminium alloys — Chemical composition |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 54-5:2017 | Fire detection and fire alarm systems - Part 5: Heat detectors - Point heat detectors |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 54-26:2015 | Fire detection and fire alarm systems - Part 26: Carbon monoxide detectors - Point detectors |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.