Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 54-12:2015

Current

Current

The latest, up-to-date edition.

Fire detection and fire alarm systems - Part 12: Smoke detectors - Line detectors using an optical beam

Published date

08-04-2015

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Testing, assessment and sampling methods
6 Assessment and verification of constancy of
  performance (AVCP)
7 Classification and designation
8 Marking, labelling and packaging
Annex A (normative) - Bench for response value measurements
Annex B (normative) - Fire test room
Annex C (normative) - Smouldering (pyrolysis) wood fire (TF2)
Annex D (normative) - Glowing smouldering cotton fire (TF3)
Annex E (normative) - Flaming plastics (polyurethane) fire (TF4)
Annex F (normative) - Flaming liquid (n-heptane) fire (TF5)
Annex G (normative) - Apparatus for stray light
Annex H (informative) - Information concerning the requirements
        for the response to slowly developing fires
Annex I (informative) - Data supplied with line detectors using
        an optical beam
Annex ZA (informative) - Clauses of this European Standard addressing
         the provisions of the EU Construction Products
         Regulation
Bibliography

This European Standard specifies requirements, test methods and performance criteria for line detectors using an optical beam that detect smoke by utilizing the attenuation and/or changes in attenuation of an optical beam, for use in fire detection and fire alarm systems installed in buildings (see EN 54 1:2011).This European Standard provides for the assessment and verification of constancy of performance (AVCP) of line detectors using an optical beam to this EN.This European Standard does not cover:-line detectors using an optical beam designed to operate with separations between opposed components of less than 1 m;-line detectors using an optical beam whose optical path length is defined or adjusted by an integral mechanical connection;-line detectors using an optical beam with special characteristics, which cannot be assessed by the test methods in this European Standard.NOTEThe term "optical" is used to describe that part of the electromagnetic spectrum produced by the transmitter to which the receiver is responsive; this is not restricted to visible wavelengths.

Committee
CEN/TC 72
DevelopmentNote
Supersedes PREN 54-12. (04/2015)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current
Supersedes

Standards Relationship
SN EN 54-12:2015 Identical
PN EN 54-12 : 2015 Identical
SS-EN 54-12:2015 Identical
ONORM EN 54-12 : 2015 Identical
UNI EN 54-12:2015 Identical
NF EN 54-12 : 2015 Identical
UNI EN 54-12 : 2003 Identical
BS EN 54-12:2015 Identical
DIN EN 54-12:2015-10 Identical
NEN EN 54-12 : 2015 Identical
NBN EN 54-12 : 2015 Identical
UNE-EN 54-12:2003 Identical
NS EN 54-12 : 2002 Identical
ÖNORM EN 54-12: 2018 Identical
I.S. EN 54-12:2015 Identical
UNE-EN 54-12:2019 Identical

DD CEN/TS 54-14:2004 Fire detection and fire alarm systems Guidelines for planning, design, installation, commissioning, use and maintenance
I.S. EN CLC TS 50398:2003 ALARM SYSTEMS - COMBINED AND INTEGRATED ALARM SYSTEMS - GENERAL REQUIREMENTS
05/30117311 DC : 0 EN 54-25 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS AND SYSTEM REQUIREMENTS
04/30119106 DC : DRAFT AUG 2004 EN 14972 - FIXED FIREFIGHTING SYSTEMS - WATERMIST SYSTEMS - DESIGN AND INSTALLATION
CEN/TS 54-14:2004 Fire detection and fire alarm systems - Part 14: Guidelines for planning, design, installation, commissioning, use and maintenance
BS 6266:2002 Code of practice for fire protection for electronic equipment installations
11/30249544 DC : 0 BS EN 54-14 - FIRE DETECTION AND FIRE ALARM SYSTEMS - GUIDELINES FOR PLANNING, DESIGN, INSTALLATION, COMMISSIONING, USE AND MAINTENANCE
I.S. CEN TS 54-14:2004 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 14: GUIDELINES FOR PLANNING, DESIGN, INSTALLATION, COMMISSIONING, USE AND MAINTENANCE

93/68/EEC : 1993 AMD 2 1998 COUNCIL DIRECTIVE 93/68/EEC OF 22.7.93 AMENDING DIRECTIVES 87/404/EEC, 88/378/EEC, 89/106/EEC, 89/336/EEC, 89/392/EEC, 89/686/EEC, 90/384/EEC, 90/385/EEC, 90/396/EEC, 91/263/EEC, 92/42/EEC AND 73/23/EEC
EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
305/2011 : 2011 AMD 2 2014 REGULATION (EU) NO 305/2011 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 9 MARCH 2011 LAYING DOWN HARMONISED CONDITIONS FOR THE MARKETING OF CONSTRUCTION PRODUCTS AND REPEALING COUNCIL DIRECTIVE 89/106/EEC (TEXT WITH EEA RELEVANCE)
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
IEC 60064:1993+AMD1:2000+AMD2:2002+AMD3:2005 CSV Tungsten filament lamps for domestic and similar general lighting purposes - Performance requirements
EN 60064:1995/A5:2009 TUNGSTEN FILAMENT LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES - PERFORMANCE REQUIREMENTS
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
ISO 9001:2015 Quality management systems — Requirements
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.