1 Scope
2 Normative references
3 Terms and definitions
4 General purpose cables
5 Heat resistant cables (90 degree C)
Annex A (normative) - Tests for cables to EN 50525-2-11
Annex B (normative) - General data
Annex C (normative) - Requirements for compatibility
test
Annex D (normative) - Special national conditions
Bibliography
EN 50525-2-11 applies to thermoplastic (PVC) insulated and PVC sheathed flexible cables. The cables are of rated voltages U0/U up to and including 300/500 V. The cables are intended for the connection of domestic appliances to the fixed supply. Circular cables and flat cables are included. The maximum conductor operating temperatures for the cables in this standard are 70 °C (VV types) and 90 °C (V2V2 types). NOTE HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-11 should be read in conjunction with EN 50525-1, which specifies general requirements.
Committee |
CLC/TC 20
|
DevelopmentNote |
Supersedes HD 21-12. Partially supersedes HD 21 PT5. To be read in conjunction with EN 50525-1. (05/2011) Supersedes PREN 50525-2-11. (08/2011)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Supersedes |
Standards | Relationship |
DIN EN 50525-2-11 : 2012 | Identical |
VDE 0285-525-2-11 : 2012 | Identical |
BS EN 50525-2-11:2011 | Identical |
NBN EN 50525-2-11 : 2011 | Identical |
I.S. EN 50525-2-11:2011 | Identical |
CEI EN 50525-2-11 : 2012 | Identical |
UNE-EN 50525-2-11:2012 | Identical |
NEN EN 50525-2-11 : 2011 | Identical |
SN EN 50525-2-11 : 2011 | Identical |
PN EN 50525-2-11 : 2011 | Identical |
NF EN 50525-2-11 : 2012 | Identical |
16/30318928 DC : 0 | BS EN ISO 19085-7 - WOODWORKING MACHINES - SAFETY - PART 7: SURFACE PLANING THICKNESS PLANING COMBINED SURFACE/THICKNESS PLANING MACHINES |
I.S. EN ISO 18217:2015 | SAFETY OF WOODWORKING MACHINES - EDGE-BANDING MACHINES FED BY CHAIN(S) (ISO 18217:2015) |
EN 1366-11:2018 | Fire resistance tests for service installations - Part 11: Fire protective systems for cable systems and associated components |
EN 60335-1:2012/A13:2017 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED) |
EN 60730-1:2016 | Automatic electrical controls - Part 1: General requirements |
15/30302620 DC : 0 | BS EN ISO 19085-4 - WOODWORKING MACHINES - SAFETY - PART 4: VERTICAL PANEL CIRCULAR SAWING MACHINES |
15/30304603 DC : 0 | BS EN 50066 - MINI-COUPLERS FOR THE INTERCONNECTION OF ELECTRICAL MAINS SUPPLIED EQUIPMENT IN ROAD VEHICLES |
PREN 1366-11 : DRAFT 2014 | FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 11: FIRE PROTECTIVE SYSTEMS FOR CABLE SYSTEMS AND ASSOCIATED COMPONENTS |
DIN EN ISO 18217:2015-12 | Safety of woodworking machines - Edge-banding machines fed by chain(s) (ISO 18217:2015) |
14/30299756 DC : 0 | BS EN 1366-11 - FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 11: FIRE PROTECTIVE SYSTEMS FOR CABLE SYSTEMS AND ASSOCIATED COMPONENTS |
I.S. EN 60335-1:2012 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS |
BS EN 60335-1 : 2012 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED) |
14/30293313 DC : 0 | BS EN ISO 19085-2 - WOODWORKING MACHINES - SAFETY - PART 2: HORIZONTAL BEAM PANEL CIRCULAR SAWING MACHINES |
14/30297793 DC : 0 | BS EN ISO 19085-3 - WOODWORKING MACHINES - SAFETY REQUIREMENTS - PART 3: NC BORING AND ROUTING MACHINES |
14/30316181 DC : 0 | BS EN 50628 - ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES |
PREN 50628 : DRAFT 2014 | ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES |
I.S. EN 60730-1:2016 | AUTOMATIC ELECTRICAL CONTROLS - PART 1: GENERAL REQUIREMENTS |
BS EN 60730-1:2011 | Automatic electrical controls for household and similar use General requirements |
ISO 18217:2015 | Safety of woodworking machines Edge-banding machines fed by chain(s) |
UNE-EN 60335-1:2012 | Household and similar electrical appliances - Safety - Part 1: General requirements |
16/30318924 DC : 0 | BS EN ISO 19085-6 - WOODWORKING MACHINES - SAFETY - PART 6: SINGLE SPINDLE VERTICAL MOULDING MACHINES ('TOUPIES') |
BS EN ISO 18217:2015 | Safety of woodworking machines. Edge-banding machines fed by chain(s) |
BS EN 50250 : 2002 | CONVERSION ADAPTORS FOR INDUSTRIAL USE |
15/30300474 DC : DRAFT FEB 2015 | BS ISO 19085-5 - WOODWORKING MACHINES - SAFETY - PART 5: DIMENSION SAWS |
16/30331355 DC : 0 | BS EN ISO 19085-8 - WOODWORKING MACHINES - SAFETY - PART 8: WIDE BELT CALIBRATING AND SANDING MACHINES |
UNE-EN ISO 18217:2016 | Safety of woodworking machines - Edge-banding machines fed by chain(s) (ISO 18217:2015) |
CEI EN 60730-1 : 2016 | AUTOMATIC ELECTRICAL CONTROLS - PART 1: GENERAL REQUIREMENTS |
PREN 50066 : DRAFT 2015 | MINI-COUPLERS FOR THE INTERCONNECTION OF ELECTRICAL MAINS SUPPLIED EQUIPMENT IN ROAD VEHICLES |
EN ISO 18217:2015 | Safety of woodworking machines - Edge-banding machines fed by chain(s) (ISO 18217:2015) |
EN 50250 : 2002 AMD 1 2015 | CONVERSION ADAPTERS FOR INDUSTRIAL USE |
EN 60719:1993 | Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V |
IEC 60228:2004 | Conductors of insulated cables |
EN ISO 6892-1:2016 | Metallic materials - Tensile testing - Part 1: Method of test at room temperature (ISO 6892-1:2016) |
ISO 6892-1:2016 | Metallic materials Tensile testing Part 1: Method of test at room temperature |
EN 60228:2005 COR 2005 | CONDUCTORS OF INSULATED CABLES |
EN 60332-1-2:2004/A11:2016 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015) |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
EN 50525-1:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements |
IEC 60811-1-2:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods |
EN 50363-3 : 2005 AMD 1 2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 3: PVC INSULATING COMPOUNDS |
EN 50363-4-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 4-1: PVC sheathing compounds |
EN 60811-1-2:1995/A2:2000 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - THERMAL AGEING METHODS |
HD 516 S2:1997/A2:2008 | GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES |
EN 50395 : 2005 AMD 1 2011 | ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
IEC 60811-1-4:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature |
EN 50396 : 2005 AMD 1 2011 | NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
EN 60811-1-4:1995/A2:2001 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.