EN 50411-2-9:2010
Current
The latest, up-to-date edition.
Fibre organisers and closures to be used in optical fibre communications systems - Product specifications - Part 2-9: Non-sealed closures for air blown fibre microduct cable, for category S & A
19-02-2010
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Description
5 Variants
6 Dimensions
7 Tests
8 Test report
9 Performance requirements
Annex A (informative) - Sample size and product sourcing
requirements
Annex B (informative) - Closure minimum internal diameters,
containing microduct connectors
Annex C (informative) - Typical buried subterranean blown
fibre microduct cable outside diameters
Annex D (informative) - Microduct definitions and sketches
Annex E (informative) - Microduct minimum bend radius
Annex F (informative) - Typical (U) closure configurations
1.1Product definitionThis specification contains the initial, start of life dimensional, mechanical and environmental performance requirements which a fully installed blown fibre protected, non-sealed closure for duct and microduct cable, must meet in order for it to be categorised as an EN standard product.These products are suitable for installation of and use with microduct fibre units, microduct optical fibre cables, microduct and protected microduct as defined within EN 60794-5.When the non-sealed closures are installed in subterranean environments it is mandatory to use sealed ABF connectors meeting EN 50411-2-8 in order to guarantee the expected network performance and reliability.1.2Operating environmentThe tests selected combined with the severities and duration are representative of an outside plant for subterranean and/or aerial environment defined by:-ETSI EN 300 019 series:Class 8.1: underground locations (without earthquake requirement);-EN 61753-1:Category S: subterranean environment;Category A: aerial environment.1.3Test severityThe test severities are based on IP40 (see EN 60529). The test criteria for all mechanical and environmental tests cover visual appearance, and protected microduct retention of the closure.It is generally accepted practice that liquids will enter the closure through its body or connected ducts.1.4ReliabilityWhilst the anticipated service life expectancy of the product in this environment is a minimum of 20 years, compliance with this specification does not guarantee the reliability of the product. This should be predicted using a recognised reliability assessment programme.1.5Quality assuranceCompliance with this specification does not guarantee the manufacturing consistency of the product. This should be maintained using a recognised quality assurance programme.1.6Allowed fibre and cable typesThis closure standard covers all IEC/EN standard optical fibre microducts, and protected microducts with their various fibre capacities, types and designs. This includes optical fibre cable standard EN 60794-5.This product specification has only considered protected microduct cables containing microducts of same outside diameters. There are other hybrid protected microduct cables with microducts of differing OD’s; it may be possible to use these hybrids, however the user must verify suitability in each case.1.7Allowed microduct connector typesThis closure standard covers all EN standard microduct connectors, including: straight, reducer/enlarger stem, reducer/enlarger, close down, liquid block, liquid block with barb end, and end stop connectors. This includes EN 50411-2-8.1.8Microduct storage constraintsMicroduct excess storage is not required in all air blown fibre closures. Some closure types do not have sufficient internal space to provide storage. The need for microduct storage is provided inside the closure when opened, typically to ensure that there is enough microduct to fulfil the following functions:•remove the coiled microduct attached to the ‘closedown’ connectors, to a remote location, close to blowing equipment, in the process uncoiling the microducts to aid blowing;•provide additional microduct if repeated cut backs for connectors are planned or likely to be fitted throughout the closure life.The minimum microduct storage bend radius is based on the outside diameter and material selection, typically based on 12 times the outside diameter (below 8 mm) and 20 times above. During fibre blowing the bend radius is typically 20 times the microduct diameter.
Committee |
CLC/TC 86BXA
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
BS EN 50411-2-9:2010 | Identical |
DIN EN 50411-2-9:2010-09 | Identical |
NF EN 50411-2-9 : 2010 | Identical |
NBN EN 50411-2-9 : 2010 | Identical |
NEN EN 50411-2-9 : 2010 | Identical |
CEI EN 50411-2-9 : 2011 | Identical |
UNE-EN 50411-2-9:2010 | Identical |
PN EN 50411-2-9 : 2010 | Identical |
I.S. EN 50411-2-9:2010 | Identical |
SN EN 50411-2-9 : 2010 | Identical |
PNE-prEN 50411-2-9 | Identical |
CEI EN 50174-3 : 2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
12/30260552 DC : 0 | BS EN 50174-3:201X - INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
I.S. EN 50174-3:2013 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
PREN 50174-3 : DRAFT 2012 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
EN 50174-3:2013/A1:2017 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
BS EN 50174-3 : 2013 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
EN 61300-2-5:2011 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion |
EN 61300-2-1:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) |
EN 61300-2-10:2012 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 2-10: TESTS - CRUSH RESISTANCE (IEC 61300-2-10:2012) |
IEC 61300-2-37:2016 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-37: Tests - Cable bending for fibre optic closures |
EN 61300-2-37:2016 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-37: Tests - Cable bending for fibre optic closures |
EN 50411-2-8:2009 | Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 2-8: Microduct connectors, for air blown optical fibres, Type 1 |
IEC 61300-2-1:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) |
IEC 61300-2-12:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-12: Tests - Impact |
EN 50411-2-5:2009 | Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 2-5: Sealed closures for air blown fibre microduct, type 1, for category S & A |
EN 50411-2:2008 | Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 2: General and guidance for optical fibre cable joint closures, protected microduct closures, and microduct connectors |
EN 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
IEC 61753-1:2007 | Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards |
EN 61753-1:2007 | Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards |
IEC 61300-2-5:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion |
IEC 61300-2-26:2006 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-26: Tests - Salt mist |
EN 61300-2-33:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-33: Tests - Assembly and disassembly of fibre optic mechanical splices, fibre management systems and closures |
IEC 60794-5:2014 | Optical fibre cables - Part 5: Sectional specification - Microduct cabling for installation by blowing |
EN 61300-2-34:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-34: Tests - Resistance to solvents and contaminating fluids of interconnecting components and closures |
ISO 1998-1:1998 | Petroleum industry Terminology Part 1: Raw materials and products |
IEC 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
EN 61300-3-1:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60068-2-10:2005 | Environmental testing - Part 2-10: Tests - Test J and guidance: Mould growth |
EN 61300-2-12:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-12: Tests - Impact |
IEC 61300-2-34:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-34: Tests - Resistance to solvents and contaminating fluids of interconnecting components and closures |
EN 61300-2-4:1997 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
EN 60794-5:2016 | Optical fibre cables - Part 5: Sectional specification - Microduct cabling for installation by blowing |
IEC 61300-2-33:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-33: Tests - Assembly and disassembly of fibre optic mechanical splices, fibre management systems and closures |
IEC 61300-2-4:1995 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 61300-2-26:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-26: Tests - Salt mist |
IEC 61300-3-1:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination |
IEC 61300-2-10:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-10: Tests - Crush resistance |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.