EN 50393:2015
Current
The latest, up-to-date edition.
Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV
13-02-2015
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Components
5 Electrical characteristics
6 Range of compliance
7 Type tests
8 Test methods
Annex A (informative) - Determination of cable conductor
temperature
Annex B (informative) - Identification of test cable
Annex C (informative) - Identification of accessory test
samples
Annex D (informative) - Identification of connector
Bibliography
This European Standard details the performance requirements and the test methods for type testing of cable accessories for use with power distribution cables of rated voltage 0,6/1,0 (1,2) kV as defined in HD 603 or other relevant cable standards.Cable accessories covered by this European Standard include joints, stop ends and outdoor terminations for extruded solid dielectric insulated cables and transition joints between extruded solid dielectric insulated and impregnated paper insulated cables. Joints, stop ends and outdoor terminations for impregnated paper insulated cables are not included.The service operating conditions of accessories should be compatible with the service operating conditions of cables on which they are to be installed.Accessories for special applications such as submarine, shipboard, explosive or seismic environments, or where specified fire performance characteristics are required, are not included.NOTE 1This European Standard does not invalidate existing approvals of products achieved on the basis of national standards and specifications and/or the demonstration of satisfactory service performance. However, products approved according to such national standards or specifications cannot directly claim approval to this European standard.NOTE 2It may be possible, subject to agreement between supplier and purchaser, and/or the relevant conformity assessment body, to demonstrate that conformity to the earlier standard can be used to claim conformity to this European Standard, provided an assessment is made of any additional type testing that may need to be carried out. Any such additional testing that is part of a sequence of testing cannot be done separately.
Committee |
CLC/TC 20
|
DevelopmentNote |
Supersedes HD 623. (04/2006) Supersedes PREN 50393. (02/2015)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Supersedes |
Standards | Relationship |
CEI EN 50393 : 2016 | Identical |
BS EN 50393:2015 | Identical |
NF EN 50393 : 2015 | Identical |
I.S. EN 50393:2015 | Identical |
NEN EN 50393 : 2015 | Identical |
VDE 0278-393:2015-10 | Identical |
NBN EN 50393 : 2015 | Identical |
PN EN 50393 : 2015 | Identical |
DIN EN 50393:2015-10 | Identical |
UNE-EN 50393:2015 | Identical |
SN EN 50393:2015 | Identical |
BS EN 50655-3:2017 | Electric cables. Accessories. Material characterization Fingerprinting for cold shrinkable components for low and medium voltage applications up to 20,8/36 (42) kV |
CEI 20-95 : 2010 | ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 2: FINGERPRINTING AND TYPE TESTS FOR HEAT SHRINKABLE COMPONENTS FOR LOW VOLTAGE APPLICATIONS |
EN 50655-3:2017 | Electric cables - Accessories - Material characterization - Part 3: Fingerprinting for cold shrinkable components for low and medium voltage applications up to 20,8/36 (42) kV |
PREN 50655-2 : DRAFT 2015 | ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 2: FINGERPRINTING FOR HEAT SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV |
I.S. HD 631.2:2007 | ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 2: FINGERPRINTING AND TYPE TESTS FOR HEAT SHRINKABLE COMPONENTS FOR LOW VOLTAGE APPLICATIONS |
HD 631.4 S1:2008 | Electrical cables - Accessories - Material characterisation - Part 4: Fingerprinting for cold shrinkable components for low and medium voltage applications up to 20,8/36 (42) kV |
HD 631.2 : 2007 | ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 2: FINGERPRINTING AND TYPE TESTS FOR HEAT SHRINKABLE COMPONENTS FOR LOW VOLTAGE APPLICATIONS |
EN 60455-3-8:2013 | Resin based reactive compounds used for electrical insulation - Part 3: Specifications for individual materials - Sheet 8: Resins for cable accessories |
I.S. EN 50655-1:2017 | ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 1: FINGERPRINTING FOR RESINOUS COMPOUNDS |
I.S. EN 50655-2:2017 | ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 2: FINGERPRINTING FOR HEAT SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV |
EN 50655-1:2017 | Electric cables - Accessories - Material characterization - Part 1: Fingerprinting for resinous compounds |
14/30267388 DC : 0 | BS EN 62677-2 ED 1.0 - HEAT SHRINKABLE LOW AND MEDIUM VOLTAGE MOULDED SHAPES - PART 2: METHODS OF TEST |
PREN 50655-3 : DRAFT 2015 | ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 3: FINGERPRINTING FOR COLD SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV |
EN IEC 62677-2:2018 | Heat shrinkable low and medium voltage moulded shapes - Part 2 Methods of test |
PREN 50655-1 : DRAFT 2015 | ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 1: FINGERPRINTING FOR RESINOUS COMPOUNDS |
17/30365113 DC : 0 | BS EN 60455-3-8 ED.2.0 - RESIN BASED REACTIVE COMPOUNDS USED FOR ELECTRICAL INSULATION - PART 3: SPECIFICATIONS FOR INDIVIDUAL MATERIALS - SHEET 8: RESINS FOR CABLE ACCESSORIES |
BS EN IEC 62677-3-102:2018 | Heat-shrinkable low and medium voltage moulded shapes Specification for individual materials. Sheet 102: Heat-shrinkable, polyolefin, anti-tracking moulded shapes for medium voltage applications |
BS EN 50655-1:2017 | Electric cables. Accessories. Material characterization Fingerprinting for resinous compounds |
I.S. EN IEC 62677-2:2018 | HEAT SHRINKABLE LOW AND MEDIUM VOLTAGE MOULDED SHAPES - PART 2: METHODS OF TEST |
CEI EN 60455-3-8 : 2014 | RESIN BASED REACTIVE COMPOUNDS USED FOR ELECTRICAL INSULATION - PART 3: SPECIFICATIONS FOR INDIVIDUAL MATERIALS - SHEET 8: RESINS FOR CABLE ACCESSORIES |
CEI 20-94 : 2010 | ELECTRICAL CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 4: FINGERPRINTING FOR COLD SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV |
IEC 62677-3-101:2018 | Heat-shrinkable low and medium voltage moulded shapes - Part 3: Specification for individual materials - Sheet 101: Heat-shrinkable, polyolefin moulded shapes for low voltage applications |
BS 7933-1:2007 | Electric cables. Accessories. Material characterisation Fingerprinting and type tests for resinous compounds |
15/30325650 DC : 0 | BS EN 50655-1 - ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 1: FINGERPRINTING FOR RESINOUS COMPOUNDS |
BS EN 60455-3-8:2013 | Resin based reactive compounds used for electrical insulation Specifications for individual materials. Sheet 8: Resins for cable accessories |
15/30325653 DC : 0 | BS EN 50655-2 - ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 2: FINGERPRINTING FOR HEAT SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV |
EN 50655-2:2017 | Electric cables - Accessories - Material characterization - Part 2: Fingerprinting for heat shrinkable components for low and medium voltage applications up to 20,8/36 (42) kV |
HD 631.1 : 200S2 | ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 1: FINGERPRINTING AND TYPE TESTS FOR RESINOUS COMPOUNDS |
I.S. EN 50628:2016 | ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES |
I.S. HD 631.4:2008 | ELECTRICAL CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 4: FINGERPRINTING FOR COLD SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV |
EN IEC 62677-3-102:2018 | Heat-shrinkable low and medium voltage moulded shapes - Part 3: Specification for individual materials - Sheet 102: Heat-shrinkable, polyolefin, anti-tracking moulded shapes for medium voltage applications |
BS EN IEC 62677-3-101:2018 | Heat-shrinkable low and medium voltage moulded shapes Specification for individual materials. Sheet 101: Heat-shrinkable, polyolefin moulded shapes for low voltage applications |
14/30316181 DC : 0 | BS EN 50628 - ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES |
IEC 62677-1:2017 | Heat shrinkable low and medium voltage moulded shapes - Part 1: General requirements |
05/30134209 DC : DRAFT MAY 2005 | HD 631.4 S1 ED. 1 - ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 4: FINGERPRINTING FOR COLD SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36(42) KV |
BS 7933-4:2008 | Electric cables. Accessories. Material characterisation Fingerprinting for cold shrinkable components for low and medium voltage applications up to 20,8/36 (42) kV |
BS 7933-2:2007 | Electric cables. Accessories. Material characterisation Fingerprinting and type tests for heat shrinkable components for low voltage applications |
I.S. EN IEC 62677-3-102:2018 | HEAT-SHRINKABLE LOW AND MEDIUM VOLTAGE MOULDED SHAPES - PART 3: SPECIFICATION FOR INDIVIDUAL MATERIALS - SHEET 102: HEAT-SHRINKABLE, POLYOLEFIN, ANTI-TRACKING MOULDED SHAPES FOR MEDIUM VOLTAGE APPLICATIONS |
PREN 50628 : DRAFT 2014 | ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES |
IEC 62677-2:2017 | Heat shrinkable low and medium voltage moulded shapes - Part 2: Methods of test |
IEC 62677-3-102:2018 | Heat-shrinkable low and medium voltage moulded shapes - Part 3: Specification for individual materials - Sheet 102: Heat-shrinkable, polyolefin, anti-tracking moulded shapes for medium voltage applications |
BS EN 50628:2016 | Erection of electrical installations in underground mines |
IEC 60455-3-8:2013 | Resin based reactive compounds used for electrical insulation - Part 3: Specifications for individual materials - Sheet 8: Resins for cable accessories |
I.S. EN 50655-3:2017 | ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 3: FINGERPRINTING FOR COLD SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV |
15/30325656 DC : 0 | BS EN 50655-3 - ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 3: FINGERPRINTING FOR COLD SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV |
CEI 20-79 : 2009 | ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 1: FINGERPRINTING AND TYPE TESTS FOR RESINOUS COMPOUNDS |
EN IEC 62677-3-101:2018 | Heat-shrinkable low and medium voltage moulded shapes - Part 3: Specification for individual materials - Sheet 101: Heat-shrinkable, polyolefin moulded shapes for low voltage applications |
15/30324018 DC : 0 | BS EN 62677-3-101 ED. 1.0 - HEAT SHRINKABLE LOW AND MEDIUM VOLTAGE MOULDED SHAPES - PART 3: MATERIAL REQUIREMENTS - SHEET 101: HEAT-SHRINKABLE, POLYOLEFIN MOULDED SHAPES FOR LOW VOLTAGE APPLICATIONS |
I.S. EN IEC 62677-3-101:2018 | HEAT-SHRINKABLE LOW AND MEDIUM VOLTAGE MOULDED SHAPES - PART 3: SPECIFICATION FOR INDIVIDUAL MATERIALS - SHEET 101: HEAT-SHRINKABLE, POLYOLEFIN MOULDED SHAPES FOR LOW VOLTAGE APPLICATIONS |
I.S. EN 60455-3-8:2013 | RESIN BASED REACTIVE COMPOUNDS USED FOR ELECTRICAL INSULATION - PART 3: SPECIFICATIONS FOR INDIVIDUAL MATERIALS - SHEET 8: RESINS FOR CABLE ACCESSORIES (IEC 60455-3-8:2013 (EQV)) |
EN 50628:2016 | Erection of electrical installations in underground mines |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60684-2:2011 | Flexible insulating sleeving - Part 2: Methods of test |
EN 61238-1:2003 | Compression and mechanical connectors for power cables for rated voltages up to 36 kV (Um = 42 kV) - Part 1: Test methods and requirements |
EN 60684-2:2011 | Flexible insulating sleeving - Part 2: Methods of test |
IEC 60055-2:1981 | Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or aluminium conductors and excluding gas-pressure and oil-filled cables). Part 2: General and construction requirements |
IEC 60455-3-8:2013 | Resin based reactive compounds used for electrical insulation - Part 3: Specifications for individual materials - Sheet 8: Resins for cable accessories |
IEC 60684-1:2003 | Flexible insulating sleeving - Part 1: Definitions and general requirements |
EN 60684-3-247:2011/A1:2017 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 247: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, DUAL WALL, NOT FLAME RETARDED, THICK AND MEDIUM WALL (IEC 60684-3-247:2011/A1:2016) |
EN 60228:2005 COR 2005 | CONDUCTORS OF INSULATED CABLES |
HD 603 S1:1994/A3:2007 | DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV |
EN 60455-3-8:2013 | Resin based reactive compounds used for electrical insulation - Part 3: Specifications for individual materials - Sheet 8: Resins for cable accessories |
EN 60684-1:2003 | Flexible insulating sleeving - Part 1: Definitions and general requirements |
IEC 61238-1:2003 | Compression and mechanical connectors for power cables for rated voltages up to 30 kV (Um = 36 kV) - Part 1: Test methods and requirements |
IEC 60050-461:2008 | International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables |
IEC 60684-3-247:2011+AMD1:2016 CSV | Flexible insulating sleeving - Part 3 Specifications for individual types of sleeving - Sheet 247: Heatshrinkable, polyolefin sleeving, dual wall, not flame retarded, thick and medium wall |
IEC 61180-1:1992 | High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements |
EN 61180-1:1994 | High-voltage test techniques for low-voltage equipment - Part 1: Definitions, test and procedure requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.