EN 50336:2002

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Bushings for transformers and reactor cable boxes not exceeding 36 kV

Superseded date

04-05-2021

Superseded by

EN 50336:2021

Published date

11-06-2002

Sorry this product is not available in your region.

1 Scope
2 Normative references
3 Definitions
4 Requirements
  4.1 Rating
      4.1.1 Standard values of rated voltage (U[r])
      4.1.2 Standard values of rated current (I[r])
  4.2 Compliance
      4.2.1 General - Ceramic bushings
      4.2.2 General - Resin insulated bushings

This standard is applicable to insulated bushings for use in air insulated, shroud insulated and fully insulated cable boxes for liquid filled transformers and reactors for rated voltages up to 36 kV, and rated currents up to 4 000 A at frequencies from 15 Hz to 60 Hz.

Committee
CLC/TC 36A
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

Standards Relationship
CEI EN 50336 : 2003 Identical
I.S. EN 50336:2002 Identical
NEN EN 50336 : 2002 Identical
DIN EN 50336:2002-12 Identical
SN EN 50336 : 2002 Identical
UNE-EN 50336:2003 Identical
PN EN 50336 : 2006 Identical
NBN EN 50336 : 2002 Identical
BS EN 50336:2002 Identical
NF EN 50336 : 2003 Identical

BS EN 50464-2-2:2007 Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2500 kVA with highest voltage for equipment not exceeding 36 kV Distribution transformers with cable boxes on the high-voltage and/or low-voltage side. Cable boxes type 1 for use on distribution transformers meeting the requirements of EN 50464-2-1
EN 50588-3:2018 Medium power transformers 50 Hz, with highest voltage for equipment not exceeding 36 kV - Part 3: Transformers with cable boxes on the high-voltage and/or low-voltage side - Cable boxes type 1 for use on transformers meeting the requirements of EN 50588-2
I.S. EN 50464-2-2:2007 THREE-PHASE OIL-IMMERSED DISTRIBUTION TRANSFORMERS 50 HZ, FROM 50 KVA TO 2 500 KVA WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 2-2: DISTRIBUTION TRANSFORMERS WITH CABLE BOXES ON THE HIGH-VOLTAGE AND/OR LOW-VOLTAGE SIDE - CABLE BOXES TYPE 1 FOR USE ON DISTRIBUTION TRANSFORMERS MEETING THE REQUIREMENTS OF EN 50464-2-1
CEI EN 50464-2-2 : 2007 THREE-PHASE OIL-IMMERSED DISTRIBUTION TRANSFORMERS 50 HZ, FROM 50 KVA TO 2500 KVA WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 2-2: DISTRIBUTION TRANSFORMERS WITH CABLE BOXES ON THE HIGH-VOLTAGE AND/OR LOW-VOLTAGE SIDE - CABLE BOXES TYPE 1 FOR USE ON DISTRIBUTION TRANSFORMERS MEETING THE REQUIREMENTS OF EN 50464-2-1
UNE-EN 50464-2-2:2010 Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 2-2: Distribution transformers with cable boxes on the high-voltage and/or low-voltage side - Cable boxes type 1 for use on distribution transformers meeting the requirements of EN 50464-2-1
I.S. EN 50588-3:2018 MEDIUM POWER TRANSFORMERS 50 HZ, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 3: TRANSFORMERS WITH CABLE BOXES ON THE HIGH-VOLTAGE AND/OR LOW-VOLTAGE SIDE - CABLE BOXES TYPE 1 FOR USE ON TRANSFORMERS MEETING THE REQUIREMENTS OF EN 50588-2
EN 50464-2-2:2007 Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 2-2: Distribution transformers with cable boxes on the high-voltage and/or low-voltage side - Cable boxes type 1 for use on distribution transformers meeting the requirements of EN 50464-2-1

EN 61099:2010 Insulating liquids - Specifications for unused synthetic organic esters for electrical purposes
IEC 61099:2010 Insulating liquids - Specifications for unused synthetic organic esters for electrical purposes
IEC 60836:2015 Specifications for unused silicone insulating liquids for electrotechnical purposes
IEC 60296:2012 RLV Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
IEC 60137:2017 Insulated bushings for alternating voltages above 1000 V
EN 22768-1:1993 General tolerances - Part 1: Tolerances for linear and angular dimensions without individual tolerance indications (ISO 2768-1:1989)
HD 565 : 200S1 SPECIFICATION FOR SILICONE LIQUIDS FOR ELECTRICAL PURPOSES
HD 428.2.1 : 200S1 THREE PHASE OIL IMMERSED DISTRIBUTION TRANSFORMERS 50 HZ, FROM 50 TO 2500 KVA WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - DISTRIBUTION TRANSFORMERS WITH CABLE BOXES ON THE HIGH VOLTAGE AND/OR LOW VOLTAGE SIDE - GENERAL REQUIREMENTS
HD 329 : 200S1 TESTS ON HOLLOW INSULATORS FOR USE IN ELECTRICAL EQUIPMENT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more