Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 50268-1:1999

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Common test methods for cables under fire conditions - Measurement of smoke density of cables burning under defined conditions - Part 1: Apparatus

Published date

23-09-1999

Superseded date

01-08-2005

Superseded by

EN 61034-1:2005

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative references
3 Definitions
4 Details of test enclosure
5 Photometric system
6 Standard fire source
7 Smoke mixing
8 Blank test
      8.1 Purpose
      8.2 Procedure
9 Qualification of test apparatus
10 Qualification burning test
      10.1 Purpose
      10.2 Preparation of cube
      10.3 Qualification smoke sources
      10.4 Test procedure
      10.5 Calculation
      10.6 Requirements
Annex A (informative) Guidance notes
Annex B (informative) Bibliography

EN 50268 specifies a method of test for measurement of smoke density of cables burning under defined conditions. It is suitable for electric insulated conductor or cable, or optical cables. This Part 1 details the apparatus. The procedure, together with an Informative Annex of recommended requirements for compliance, is given in Part 2. NOTE: Experience has shown that the test protocol is not suitable for some cables that exceed 70 mm overall diameter. In such cases the manufacturer should be consulted

Committee
CLC/TC 20
DevelopmentNote
Supersedes HD 606.1 (12/2002)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy
Supersedes

HD 21.1 : 200S4 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - GENERAL REQUIREMENTS
CEI UNI EN 45510-2-8 : 2006 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES
EN 45510-2-8 : 2004 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES
HD 22-1 : 200S4 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOSETTING INSULATION - GENERAL REQUIREMENTS
EN 50268-2:1999 Common test methods for cables under fire conditions - Measurement of smoke density of cables burning under defined conditions - Part 2: Procedure
04/19990095 DC : 0 BS EN 45545-2 - RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS
I.S. HD 22-1:2002 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 1: GENERAL REQUIREMENTS
DIN EN 50268-2 : 2000 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 2: PROCEDURE
CEI EN 50362 : 2003 METHOD OF TEST FOR RESISTANCE TO FIRE OF LARGER UNPROTECTED POWER AND CONTROL CABLES FOR USE IN EMERGENCY CIRCUITS
EN 50362:2003 Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits
EN 45510-2-8:2004 Guide for procurement of power station equipment - Part 2-8: Electrical equipment - Power cables
BS EN 45510-2-8:2004 Guide for procurement of power station equipment Electrical equipment - Power cables
I.S. HD 21-1:2002 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 1: GENERAL REQUIREMENTS
BS EN 50268-2:2000 Common test methods for cables under fire conditions. Measurement of smoke density of cables burning under defined conditions Procedure
01/207832 DC : DRAFT NOV 2001 PRHD 21.1 S4 - CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 1: GENERAL REQUIREMENTS
I.S. EN 50362:2003 METHOD OF TEST FOR RESISTANCE TO FIRE OF LARGER UNPROTECTED POWER AND CONTROL CABLES FOR USE IN EMERGENCY CIRCUITS
I.S. HD 21-2:1998 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2: TEST METHODS
I.S. EN 45510-2-8:2004 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES
01/207833 DC : DRAFT NOV 2001 PRHD 22.1 S4 - CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOSETTING INSULATION - PART 1: GENERAL REQUIREMENTS
VDE 0482-268-2 : 2000 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 2: PROCEDURE
BS EN 50362:2003 Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits
HD 22.2 S3:1997/A1:2002 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOSETTING INSULATION - TEST METHODS
HD 21-2 : S3 AMD 1 2002 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - TEST METHODS

EN 60695-4:2012 Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products

Access your standards online with a subscription

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Sorry this product is not available in your region.