EN 50167:1994
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Sectional specification for horizontal floor wiring cables with a common overall screen for use in digital communication
01-02-2001
07-10-1994
1 Guide to use
1.1 Scope
1.2 Introduction
1.3 Installation considerations
1.4 Object
2. Definitions and requirements
2.1 General
2.2 Reference publications
2.3 Definitions
2.4 Materials and cable construction
2.4.1 General
2.4.2 Cable construction
2.4.3 Conductor
2.4.4 Insulation
2.4.5 Cable element
2.4.6 Screening of the cable element
2.4.7 Colour code of insulation
2.4.8 Cable make-up
2.4.9 Screening of the cable core
2.4.10 Sheath
2.4.11 Colour of sheath
2.4.12 Identification
2.4.13 Finished cable
2.4.14 Cable overall diameter
3 Characteristics and requirements
3.1 General
3.2 Electrical tests
3.2.1 Conductor resistance
3.2.2 Resistance unbalance
3.2.3 Dielectric strength
3.2.4 Insulation resistance
3.2.5 Mutual capacitance
3.2.6 Capacitance unbalance
3.2.7 Transfer impedance
3.3 Transmission characteristics
3.3.1 Velocity of propagation
3.3.2 Attenuation
3.3.3 Unbalance attenuation
3.3.4 Near-end crosstalk
3.3.5 Far-end crosstalk
3.3.6 Characteristics impedance
3.3.7 Structural Return Loss (SRL)
3.3.8 Longitudinal to Differential Conversion
Loss (LCL)
3.4 Mechanical and dimension characteristics and
requirements
3.4.1 Dimensional requirements
3.4.2 Elongation at break of conductors
3.4.3 Elongation and tensile strength at break of
the insulation
3.4.4 Elongation and tensile strength at break of sheath
3.4.5 Crushing of the cable
3.4.6 Impact test on the cable
3.4.7 Repeated bending of the cable
3.4.8 Tensile performance of the cable
3.5 Environmental characteristics
3.5.1 Shrinkage of insulation
3.5.2 Wrapping of insulation after thermal ageing
3.5.3 Bending of insulation at low temperature
3.5.4 Elongation and tensile strength at break of the
sheath after ageing
3.5.5 Sheath pressure test at high temperature
3.5.6 Cold bend of the cable
3.5.7 Heat shock
3.5.8 Flame propagation characteristics of single cable
3.5.9 Flame propagation characteristics of bunched
cables
3.5.10 Acid gas evolution
3.5.11 Smoke generation
3.5.12 Toxic gas emission
4 Quality assessment procedures
Annex A (informative) Attenuation NEXT and ACR
This standard refers to HD 608 S1:1992, Generic specification for symmetrical pair/quad or multicore cables for digital communications. It covers individually screened pair(s) or quad(s) in cables for horizontal floor wiring. In the same cable both screened and unscreened elements may be used. The cables shall be provided with a common overall screen. These cables are suitable for different communication systems to which reference is made in the detail specifications. The cables covered by this specification are intended to operate with voltages and currents normally adopted for communication systems. These cables shall not be connected to low impedance sources, for example, the public mains electricity supply
Committee |
CLC/TC 46X
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
SN EN 50167 : 1994 | Identical |
DIN EN 50167 : 1995 | Identical |
UNE-EN 50167:1996 | Identical |
NF EN 50167 : 1995 | Identical |
BS EN 50167:1996 | Identical |
NEN EN 50167 : 1994 | Identical |
I.S. EN 50167:1995 | Identical |
NBN EN 50167 : 1995 | Identical |
CEI EN 50167 : 1ED 1998 | Identical |
VDE 0819-2 : 1995 | Identical |
DIN EN 50173:2000-07 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS |
HD 606.1 : 200S1 | MEASUREMENT OF SMOKE DENSITY OF ELECTRIC CABLES BURNING UNDER DEFINED CONDITIONS - TEST APPARATUS |
HD 606.2 : 200S1 | MEASUREMENT OF SMOKE DENSITY OF ELECTRIC CABLES BURNING UNDER DEFINED CONDITIONS - TEST PROCEDURE AND REQUIREMENTS |
HD 624.5 : 200S1 | MATERIALS USED IN COMMUNICATION CABLES - POLYPROPYLENE INSULATION COMPOUNDS |
HD 624.7 : 200S1 | MATERIALS USED IN COMMUNICATION CABLES - HALOGEN FREE FLAME RETARDANT THERMOPLASTIC SHEATHING COMPOUND |
IEC TR 60344:2007 | Calculation of d.c. resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide |
HD 624.3 : S1 AMD 2 94 | MATERIALS USED IN COMMUNICATION CABLES - PE SOLID INSULATION |
HD 602 : 200S1 | TEST ON GASES EVOLVED DURING COMBUSTION OF ELECTRIC CABLES - DETERMINATION OF DEGREE OF ACIDITY OF GASES EVOLVED DURING THE COMBUSTION OF MATERIALS TAKEN FROM ELECTRIC CABLES BY MEASURING PH CONDUCTIVITY |
HD 624.6 : 200S1 | MATERIALS USED IN COMMUNICATION CABLES - HALOGEN FREE FLAME RETARDANT INSULATION COMPOUNDS |