Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Functional requirements
5 Marking
6 Documentation
7 Tests
Annex A (informative) - Determination of
Storage Device failure
Annex B (normative) - Measurement of ripple
voltage
Annex C (normative) - Measurement of transients
Annex D (informative) - Test on Demand signal or
message timing and usage protocol
Annex E (informative) - Cross-reference between
requirements and corresponding tests
This European Standard specifies the requirements, performance criteria and testing procedures for PS to be used as part of Intrusion and Hold up Alarm Systems. The PS will either be an integral part of an I&HAS component or stand-alone. The control functions of the PS may be incorporated as part of the PS device, or may be provided by another I&HAS component, e.g. a CIE.
This European Standard is not applicable when the PS requirements for I&HAS components are included within the relevant product standard.
The requirements correspond to each of the four security grades given in the European Standard EN 50131 1, Alarm Systems - Intrusion and Hold-Up Systems - Part 1: System requirements. Requirements are also given for four environmental classes covering applications in indoor and outdoor locations.
This standard covers:
a)mandatory functions which will be provided on all PS; and
b)optional functions which may be provided.
This European Standard does not deal with requirements for compliance with EC regulatory Directives, such as the EMC Directive, Low Voltage Directive, etc. except that it specifies the equipment operating conditions and reduced functional test for EMC susceptibility testing as required by EN 50130 4.
Other functions associated with I&HAS not specified in this standard may be provided. Such functions will not affect the requirements of any mandatory or optional functions.
Committee |
CLC/TC 79
|
DevelopmentNote |
Supersedes PREN 50131-6. (10/2017)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
UNE-EN 50131-6:2008 | Identical |
DIN EN 50131-6 : 2015 | Identical |
I.S. EN 50131-6:2008 | Identical |
DIN EN 50131-6:2018-07 | Identical |
SN EN 50131-6 : 2008 AMD 1 2014 | Identical |
BS EN 50131-6 : 2008 | Identical |
NEN EN 50131-6 : 2017 | Identical |
NBN EN 50131-6 : 2008 AMD 1 2014 | Identical |
CEI EN 50131-6 : 2018 | Identical |
VDE 0830-2-6 : 2015 | Identical |
VDE 0830-2-6:2018 | Identical |
DIN EN 50131-6:2021-12 | Identical |
UNE-EN 50131-6:2018 | Identical |
PN EN 50131-6 : 2017 | Identical |
NF EN 50131-6 : 2017 | Identical |
BS EN 50131-6:2017 | Identical |
I.S. EN 50131-6:2017 | Identical |
BS EN 50131-2-7-3 : 2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-3: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACTIVE) |
CLC/TS 50131-2-5:2004 | Alarm systems - Intrusion systems - Part 2-5: Requirements for combined passive infrared and ultrasonic detectors |
CLC/TS 50131-2-6:2004 | Alarm systems - Intrusion systems - Part 2-6: Requirements for opening contacts (magnetic) |
16/30349685 DC : 0 | BS EN 50131-2-2 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-2: INTRUSION DETECTORS - PASSIVE INFRARED DETECTORS |
07/30170080 DC : DRAFT AUG 2007 | PREN 50131-2-6 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-6: OPENING CONTACTS (MAGNETIC) |
I.S. EN 50131-10:2014 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 10: APPLICATION SPECIFIC REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT) |
BS EN 50131-2-2:2017 | Alarm systems. Intrusion and hold-up systems Intrusion detectors. Passive infrared detectors |
DD CLC/TS 50131-2-3:2004 | Alarm systems. Intrusion systems Requirements for microwave detectors |
CLC/TS 50131-2-3:2004 | Alarm systems - Intrusion systems - Part 2-3: Requirements for microwave detectors |
I.S. EN 50131-2-2:2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-2: INTRUSION DETECTORS - PASSIVE INFRARED DETECTORS |
PD CLC/TS 50131-2-9:2016 | Alarm systems. Intrusion and hold-up systems Intrusion detectors. Active infrared beam detectors |
BS EN 50131-2-7-2 : 2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-2: INTRUSION DETECTORS - GLASS BREAK DETECTORS (PASSIVE) |
BS EN 50131-2-5:2008 | Alarm systems. Intrusion and hold-up systems Requirements for combined passive infrared and ultrasonic detectors |
PD CLC/TS 50131-2-10:2014 | Alarm systems. Intrusion and hold-up systems Intrusion detectors. Lock state contacts (magnetic) |
CLC/TS 50661-1:2017 | Alarm systems - External perimeter security systems - Part 1: System requirements |
S.R. CLC/TS 50131-2-7-3:2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-3: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACTIVE) |
IEC 62642-1:2010 | Alarm systems - Intrusion and hold-up systems - Part 1: System requirements |
S.R. CLC/TS 50661-1:2017 | ALARM SYSTEMS - EXTERNAL PERIMETER SECURITY SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
I.S. CLC TS 50131-3:2003 | ALARM SYSTEMS - INTRUSION SYSTEMS - PART 3: CONTROL AND INDICATING EQUIPMENT |
CEI EN 50131-2-3 : 2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-3: REQUIREMENTS FOR MICROWAVE DETECTORS |
I.S. EN 50131-2-7-1:2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-1: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACOUSTIC) |
OVE/ONORM EN 50131-2-4 : 2008 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-4: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND MICROWAVE DETECTORS |
CLC/TS 50131-3:2003 | Alarm systems - Intrusion systems - Part 3: Control and indicating equipment |
EN 50131-10:2014 | Alarm systems - Intrusion and hold-up systems - Part 10: Application specific requirements for Supervised Premises Transceiver (SPT) |
EN 50131-2-8:2016 | Alarm systems - Intrusion and hold-up systems - Part 2-8: Intrusion detectors - Shock detectors |
OVE/ONORM EN 50131-2-3 : 2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-3: REQUIREMENTS FOR MICROWAVE DETECTORS |
08/30180887 DC : DRAFT MAY 2008 | BS EN 50131-4 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 4: WARNING DEVICES |
17/30353695 DC : 0 | BS EN 50131-4 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 4: WARNING DEVICES |
99/703461 DC : DRAFT AUG 1999 | BS EN 50131-2-2 - ALARM SYSTEMS - INTRUSION SYSTEMS - PART 2-2: REQUIREMENTS FOR PASSIVE INFRARED DETECTORS |
02/708067 DC : DRAFT SEP 2002 | BS EN 50131-2-4 - ALARM SYSTEMS - INTRUSION SYSTEMS - PART 2-4: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND MICROWAVE DETECTORS |
BS EN 50131-2-4:2008 | Alarm systems. Intrusion and hold-up systems Requirements for combined passive infrared and microwave detectors |
PD CLC/TS 50131-11:2012 | Alarm systems. Intrusion and hold-up systems Hold-up devices |
CEI EN 50131-2-6 : 2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-6: OPENING CONTACTS (MAGNETIC) |
BS EN 50131-2-8:2016 | Alarm systems. Intrusion and hold-up systems Intrusion detectors. Shock detectors |
PD CLC/TS 50661-1:2017 | Alarm systems. External perimeter security systems System requirements |
BS EN 50131-3:2009 | Alarm systems. Intrusion and hold-up systems Control and indicating equipment |
DD CLC/TS 50131-2-7-2:2009 | Alarm systems. Intrusion and hold-up systems Intrusion detectors. Glass break detectors (passive) |
CEI EN 50131-1 : 2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
UNE-EN 50131-10:2014 | Alarm systems - Intrusion and hold-up systems - Part 10: Application specific requirements for Supervised Premises Transceiver (SPT) |
I.S. EN 50131-2-6:2008 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-6: OPENING CONTACTS (MAGNETIC) |
I.S. EN 50131-2-4:2008 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-4: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND MICROWAVE DETECTORS |
BS EN 50131-1 : 2006 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
I.S. EN 50131-2-8:2016 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-8: INTRUSION DETECTORS - SHOCK DETECTORS |
I.S. EN 50131-2-7-3:2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-3: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACTIVE) |
CEI EN 50131-2-4 : 2008 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-4: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND MICROWAVE DETECTORS |
CLC/TS 50131-2-7-1:2009 | Alarm systems - Intrusion and hold-up systems - Part 2-7-1: Intrusion detectors - Glass break detectors (acoustic) |
S.R. CLC/TS 50131-2-7-2:2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-2: INTRUSION DETECTORS - GLASS BREAK DETECTORS (PASSIVE) |
I.S. EN 50131-1:2006 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
EN 50131-2-4:2008 | Alarm systems - Intrusion and hold-up systems - Part 2-4: Requirements for combined passive infrared and microwave detectors |
07/30162539 DC : 0 | BS EN 50131-2-2 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-2: INTRUSION DETECTORS - PASSIVE INFRARED DETECTORS |
BS EN 50131-10:2014 | Alarm systems. Intrusion and hold-up systems Application specific requirements for Supervised Premises Transceiver (SPT) |
DD CLC/TS 50131-2-5:2004 | Alarm systems. Intrusion systems Requirements for combined passive infrared and ultrasonic detectors |
TR 103 056 : 1.1.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); SYSTEM REFERENCE DOCUMENT; SHORT RANGE DEVICES (SRD); TECHNICAL CHARACTERISTICS FOR SRD EQUIPMENT FOR SOCIAL ALARM AND ALARM APPLICATIONS |
DD CLC/TS 50131-2-4:2004 | Alarm systems. Intrusion systems Requirements for combined passive infrared and microwave detectors |
PD CLC/TR 50531:2009 | Alarm systems. Terms and definitions |
CEI EN 50131-2-7-1 : 2013 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-1: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACOUSTIC) |
CEI CLC/TS 50131-2-11 : 1ED 2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-11: INTRUSION DETECTORS - ALDDR |
BS EN 50131-2-7-1 : 2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-1: INTRUSION DETECTORS - GLASS BREAK DETECTORS (PASSIVE) |
EN 50131-1:2006/A2:2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
IEC 62642-3:2010 | Alarm systems - Intrusion and hold-up systems - Part 3: Control and indicating equipment |
S.R. CLC/TS 50131-2-9:2016 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-9: INTRUSION DETECTORS - ACTIVE INFRARED BEAM DETECTORS |
I.S. EN 50131-3:2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 3: CONTROL AND INDICATING EQUIPMENT |
S.R. CLC/TS 50131-2-11:2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-11: INTRUSION DETECTORS - ALDDR |
CLC/TR 50531:2009 | Alarm systems - Terms and definitions |
EN 50131-2-2:2017 | Alarm systems - Intrusion and hold-up systems - Part 2-2: Intrusion detectors - Passive infrared detectors |
S.R. CLC/TS 50131-2-10:2014 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-10: INTRUSION DETECTORS - LOCK STATE CONTACTS (MAGNETIC) |
BS EN 50131-2-3:2008 | Alarm systems. Intrusion and hold-up systems Requirements for microwave detectors |
CEI CLC/TS 50131-2-9 : 1ED 2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-9: INTRUSION DETECTORS - ACTIVE INFRARED BEAM DETECTORS |
DD CLC/TS 50131-4:2006 | Alarm systems. Intrusion and hold-up systems Warning devices |
CEI EN 50131-2-7-2 : 2013 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-2: INTRUSION DETECTORS - GLASS BREAK DETECTORS (PASSIVE) |
DD CLC/TS 50131-2-7-1:2009 | Alarm systems. Intrusion and hold-up systems Intrusion detectors. Glass break detectors (acoustic) |
CLC/TS 50131-2-11:2017 | Alarm systems - Intrusion and hold-up systems - Part 2-11: Intrusion detectors - ALDDR |
BS EN 50131-2-6:2008 | Alarm systems. Intrusion and hold-up systems Opening contacts (magnetic) |
DD CLC/TS 50131-2-2:2004 | Alarm systems. Intrusion systems Requirements for passive infrared detectors |
CEI CLC/TS 50131-2-8 : 2013 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-8: INTRUSION DETECTORS - SHOCK DETECTORS |
PD CLC/TS 50131-2-8:2012 | Alarm systems. Intrusion and hold-up systems Intrusion detectors. Shock detectors |
11/30245742 DC : 0 | BS EN 50131-10 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 10: APPLICATION SPECIFIC REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT) |
CLC/TS 50131-2-7-2:2009 | Alarm systems - Intrusion and hold-up systems - Part 2-7-2: Intrusion detectors - Glass break detectors (passive) |
UNE-EN 50131-2-7-1:2013 | Alarm systems - Intrusion and hold-up systems - Part 2-7-1: Intrusion detectors - Glass break detectors (acoustic) |
CLC/TS 50131-2-8:2012 | Alarm systems - Intrusion and hold-up systems - Part 2-8: Intrusion detectors - Shock detectors |
UNE-EN 50131-2-8:2017 | Alarm systems - Intrusion and hold-up systems - Part 2-8: Intrusion detectors - Shock detectors |
S.R. CLC/TS 50131-11:2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 11: HOLD-UP DEVICES |
S.R. CLC/TR 50531:2009 | ALARM SYSTEMS - TERMS AND DEFINITIONS |
I.S. CLC TS 50131-4:2006 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 4: WARNING DEVICES |
I.S. EN 50131-2-7-3:2012/A2:2016 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-3: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACTIVE) |
I.S. EN 50131-4:2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 4: WARNING DEVICES |
I.S. EN 50131-2-5:2008 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-5: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND ULTRASONIC DETECTORS |
UNE-EN 50131-2-7-2:2013 | Alarm systems - Intrusion and hold-up systems - Part 2-7-2: Intrusion detectors - Glass break detectors (passive) |
UNE-EN 50131-2-7-3:2013 | Alarm systems - Intrusion and hold-up systems - Part 2-7-3: Intrusion detectors - Glass break detectors (active) |
CLC/TS 50131-2-10:2014 | Alarm systems - Intrusion and hold-up systems - Part 2-10: Intrusion detectors - Lock state contacts (magnetic) |
PREN 50131-2-2 : DRAFT 2016 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-2: INTRUSION DETECTORS - PASSIVE INFRARED DETECTORS |
PREN 50131-10 : DRAFT 2011 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 10: APPLICATION SPECIFIC REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT) |
DD CLC/TS 50131-2-7-3:2009 | Alarm systems. Intrusion and hold-up systems Intrusion detectors. Glass break detectors (active) |
DD CLC/TS 50131-2-6:2004 | Alarm systems. Intrusion systems Requirements for opening contacts (magnetic) |
I.S. EN 50131-2-3:2008 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-3: REQUIREMENTS FOR MICROWAVE DETECTORS |
CEI EN 50131-2-7-3 : 2013 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-3: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACTIVE) |
CEI EN 50131-3 : 2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 3: CONTROL AND INDICATING EQUIPMENT |
CEI CLC/TS 50131-11 : 2013 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 11: HOLD-UP DEVICES |
CEI EN 50131-2-2 : 2008 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-2: INTRUSION DETECTORS - PASSIVE INFRARED DETECTORS |
DD CLC/TS 50131-3:2003 | Alarm systems. Intrusion systems Control and indicating equipment |
I.S. EN 50131-2-7-2:2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-2: INTRUSION DETECTORS - GLASS BREAK DETECTORS (PASSIVE) |
CEI EN 50131-2-5 : 2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-5: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND ULTRASONIC DETECTORS |
CEI EN 50131-2-8 : 1ED 2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-8: INTRUSION DETECTORS - SHOCK DETECTORS |
07/30162638 DC : 0 | BS 50131-2-3 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-3: REQUIREMENTS FOR MICROWAVE DETECTORS |
PD CLC/TS 50131-2-11:2017 | PD CLC/TS 50131-2-11 Alarm systems - Intrusion and hold-up systems Part 2-11: Intrusion detectors - ALDDR |
07/30162640 DC : 0 | BS EN 50131-2-4 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-4: REQUIREMENTS FOR COMBINED PASSIVE INFRA-RED AND MICROWAVE DETECTORS |
UNE-EN 50131-4:2010 | Alarm systems - Intrusion and hold-up systems - Part 4: Warning devices |
07/30162643 DC : DRAFT AUG 2007 | BS EN 50131-2-5 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-5: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND ULTRASONIC DETECTORS |
CLC/TS 50131-2-4:2004 | Alarm systems - Intrusion systems - Part 2-4: Requirements for combined passive infrared and microwave detectors |
S.R. CLC/TS 50131-2-7-1:2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-1: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACOUSTIC) |
PREN 50131-4 : DRAFT 2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 4: WARNING DEVICES |
UNE-EN 50131-1:2008 | Alarm systems - Intrusion and hold-up systems -- Part 1: System requirements |
OVE/ONORM EN 50131-2-2 : 2008 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-2: INTRUSION DETECTORS - PASSIVE INFRARED DETECTORS |
CLC/TS 50131-2-2:2004 | Alarm systems - Intrusion systems - Part 2-2: Requirements for passive infrared detectors |
CLC/TS 50131-2-7-3:2009 | Alarm systems - Intrusion and hold-up systems - Part 2-7-3: Intrusion detectors - Glass break detectors (active) |
S.R. CLC/TS 50131-2-8:2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-8: INTRUSION DETECTORS - SHOCK DETECTORS |
BS EN 50131-4:2009 | Alarm systems. Intrusion and hold-up systems Warning devices |
CEI EN 50131-4 : 2010 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 4: WARNING DEVICES |
EN 50131-3:2009 | Alarm systems - Intrusion and hold-up systems - Part 3: Control and indicating equipment |
CLC/TS 50131-11:2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 11: HOLD-UP DEVICES |
EN 50131-2-7-3:2012/A2:2016 | Alarm systems - Intrusion and hold-up systems - Part 2-7-3: Intrusion detectors - Glass break detectors (active) |
EN 50131-2-6:2008 | Alarm systems - Intrusion and hold-up systems - Part 2-6: Opening contacts (magnetic) |
EN 50131-2-7-2 : 2012 AMD 2 2016 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-2: INTRUSION DETECTORS - GLASS BREAK DETECTORS (PASSIVE) |
EN 50131-2-3:2008 | Alarm systems - Intrusion and hold-up systems - Part 2-3: Requirements for microwave detectors |
EN 50131-2-5:2008 | Alarm systems - Intrusion and hold-up systems - Part 2-5: Requirements for combined passive infrared and ultrasonic detectors |
EN 50131-2-7-1:2012/A2:2016 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-1: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACOUSTIC) |
CLC/TS 50131-4:2006 | Alarm systems - Intrusion and hold-up systems - Part 4: Warning devices |
EN 50131-4:2009 | Alarm systems - Intrusion and hold-up systems - Part 4: Warning devices |
EN 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 50130-5:2011 | ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.