1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Application of the tests
5 Conditions during testing
6 Functional test
7 Mains supply voltage variations
8 Mains supply voltage dips and short interruptions
9 Electrostatic discharge
10 Radiated electromagnetic fields
11 Conducted disturbances induced by electromagnetic fields
12 Fast transient bursts
13 Slow high energy voltage surge
14 Conducted, common mode disturbances from 0 Hz to
   150 kHz
Annex ZZ (informative) - Coverage of Essential Requirements
         of EC Directives
Bibliography

This EMC product-family standard, for immunity requirements, applies to the components of the following alarm systems, intended for use in and around buildings in residen¬tial, commercial, light industrial and industrial environments: – access control systems, for security applications; – alarm transmission systems 1); – CCTV systems, for security applications; – fire detection and fire alarm systems; – hold-up alarm systems; – intruder alarm systems; – social alarm systems; The tests and severities to be used are the same for indoor and outdoor applications of fixed, movable and portable equipment.

Committee
TC 79
DevelopmentNote
Supersedes PREN 50130-4. (08/2011)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current
Supersedes

BS EN 50131-2-7-3 : 2012 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-3: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACTIVE)
CLC/TS 50131-2-5:2004 Alarm systems - Intrusion systems - Part 2-5: Requirements for combined passive infrared and ultrasonic detectors
UNE-EN 54-22:2016 Fire detection and fire alarm system - Part 22 : Resettable line-type heat detectors
04/30080013 DC : DRAFT FEB 2004 EN 50131-1 - ALARM SYSTEMS - INTRUSION SYSTEMS - PART 1: SYSTEM REQUIREMENTS
03/106844 DC : DRAFT MAY 2003 ISO 7240-11 - FIRE DETECTION AND ALARM SYSTEMS - PART 11: MANUAL CALL POINTS
CLC/TS 50131-2-6:2004 Alarm systems - Intrusion systems - Part 2-6: Requirements for opening contacts (magnetic)
BS EN 54-28:2016 Fire detection and fire alarm system Non-resettable line-type heat detectors
16/30349685 DC : 0 BS EN 50131-2-2 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-2: INTRUSION DETECTORS - PASSIVE INFRARED DETECTORS
BS EN 54-16:2008 Fire detection and fire alarm systems Voice alarm control and indicating equipment
BS EN 54-31 : 2014 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 31: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE, CARBON MONOXIDE AND OPTIONALLY HEAT SENSORS
13/30280627 DC : 0 BS ISO 7240-15 - FIRE DETECTION AND ALARM SYSTEMS - PART 15: POINT-TYPE FIRE DETECTORS USING SMOKE AND HEAT SENSORS
11/30240275 DC : 0 BS EN 54-22 - FIRE DETECTION AND FIRE ALARM SYSTEM - PART 22: RESETTABLE LINE TYPE HEAT DETECTORS
BS ISO 21927-10:2011 Smoke and heat control systems Specification for power output devices
07/30170080 DC : DRAFT AUG 2007 PREN 50131-2-6 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-6: OPENING CONTACTS (MAGNETIC)
I.S. EN 50131-10:2014 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 10: APPLICATION SPECIFIC REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT)
10/30210160 DC : 0 BS ISO 12239 - SMOKE ALARMS
BS EN 50131-2-2:2017 Alarm systems. Intrusion and hold-up systems Intrusion detectors. Passive infrared detectors
PD CLC/TS 50136-7:2017 Alarm systems. Alarm transmission systems and equipment Application guidelines
PD CLC/TS 50661-1:2017 Alarm systems. External perimeter security systems System requirements
DD CLC/TS 50131-2-3:2004 Alarm systems. Intrusion systems Requirements for microwave detectors
03/106843 DC : DRAFT MAY 2003 ISO 7240-6 - FIRE DETECTION AND ALARM SYSTEMS - PART 6: POINT-TYPE FIRE DETECTORS FOR DETECTION OF CARBON MONOXIDE
PREN 54-11 : DRAFT 2013 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 11: MANUAL CALL POINTS
04/30122860 DC : DRAFT SEP 2004 ISO 7240-22 - FIRE DETECTION AND FIRE ALARM EQUIPMENT - PART 22: DUCT SAMPLING EQUIPMENT
CEN/TR 16705:2014 Perimeter protection - Performance classification methodology
PREN 54-20 : DRAFT 2014 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 20: ASPIRATING SMOKE DETECTORS
CLC/TS 50131-2-3:2004 Alarm systems - Intrusion systems - Part 2-3: Requirements for microwave detectors
PREN 14604 : DRAFT 2016 SMOKE ALARM DEVICES
04/30109635 DC : 0 BS EN 54-23 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 23: FIRE ALARM DEVICES - VISUAL ALARMS
05/30135750 DC : DRAFT JUL 2005 ISO 7240-10 - FIRE DETECTION AND ALARM SYSTEMS - PART 10: POINT-TYPE FLAME DETECTORS
PREN 54-10 : DRAFT 2012 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 10: FLAME DETECTORS - POINT DETECTORS
07/30163407 DC : 0 BS ISO 7240-28 - FIRE DETECTION AND ALARM SYSTEMS - PART 28: FIRE PROTECTION CONTROL EQUIPMENT
BS EN 50132-1:2010 Alarm systems. CCTV surveillance systems for use in security applications System requirements
I.S. EN 50131-2-2:2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-2: INTRUSION DETECTORS - PASSIVE INFRARED DETECTORS
11/30251478 DC : 0 BS EN 1300 - SECURE STORAGE UNITS - CLASSIFICATION FOR HIGH SECURITY LOCKS ACCORDING TO THEIR RESISTANCE TO UNAUTHORIZED OPENING
PD CLC/TS 50131-2-9:2016 Alarm systems. Intrusion and hold-up systems Intrusion detectors. Active infrared beam detectors
BS EN 50131-2-7-2 : 2012 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-2: INTRUSION DETECTORS - GLASS BREAK DETECTORS (PASSIVE)
09/30184483 DC : 0 BS EN 54-3 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 3: FIRE ALARM DEVICES - SOUNDERS
02/540596 DC : DRAFT JULY 2002 PREN 54-17 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 17: SHORT CIRCUIT ISOLATORS
BS EN 50131-2-5:2008 Alarm systems. Intrusion and hold-up systems Requirements for combined passive infrared and ultrasonic detectors
BS EN 50131-1 : 2006 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
09/30197779 DC : 0 BS ISO 7240-25 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO TRANSMISSION PATHS
BS EN 50132-2-1:1998 Alarm systems. CCTV surveillance systems for use in security applications Black and white cameras
BS EN 50131-8:2009 Alarm systems. Intrusion and hold-up systems Security fog device/systems
PD CLC/TS 50131-2-10:2014 Alarm systems. Intrusion and hold-up systems Intrusion detectors. Lock state contacts (magnetic)
PREN 50134-3 : DRAFT 2009 ALARM SYSTEMS - SOCIAL ALARM SYSTEMS - PART 3: LOCAL UNIT AND CONTROLLER
CLC/TS 50661-1:2017 Alarm systems - External perimeter security systems - Part 1: System requirements
CLC/TS 50136-7:2017 Alarm systems - Alarm transmission systems and equipment - Part 7: Application guidelines
PREN 54-12 : DRAFT 2009 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 12: SMOKE DETECTORS - LINE DETECTORS USING AN OPTICAL BEAM
S.R. CLC/TS 50131-2-7-3:2009 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-3: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACTIVE)
PREN 50131-2-10 : DRAFT 2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-10: INTRUSION DETECTORS - LOCK STATE CONTACTS (MAGNETIC)
CEI EN 50134-2 : 2000 ALARM SYSTEMS - SOCIAL ALARM SYSTEMS - PART 2: TRIGGER DEVICES
I.S. EN 54-23:2010 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 23: FIRE ALARM DEVICES - VISUAL ALARM DEVICES
I.S. EN 54-30:2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 30: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF CARBON MONOXIDE AND HEAT SENSORS
CEI EN 50131-2-3 : 2009 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-3: REQUIREMENTS FOR MICROWAVE DETECTORS
PREN 54-7 : DRAFT 2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONISATION
BIS IS/ISO 7240-5 : 2003 FIRE DETECTION AND ALARM SYSTEMS - PART 5: POINT-TYPE HEAT DETECTORS
I.S. EN 50131-2-7-1:2012 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-1: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACOUSTIC)
16/30315066 DC : 0 BS EN 14604 - SMOKE ALARM DEVICES
14/30274689 DC : 0 BS EN 54-20 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 20: ASPIRATING SMOKE DETECTORS
OVE/ONORM EN 50131-2-4 : 2008 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-4: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND MICROWAVE DETECTORS
BS EN 14373:2005 Explosion suppression systems
DIN EN 54-17:2006-03 Fire detection and fire alarm systems - Part 17: Short-circuit isolators
CLC/TS 50131-3:2003 Alarm systems - Intrusion systems - Part 3: Control and indicating equipment
EN 50131-8:2009 Alarm systems - Intrusion and hold-up systems - Part 8: Security fog device/systems
EN 50132-5-3:2012 Alarm systems - CCTV surveillance systems for use in security applications - Part 5-3: Video transmission - Analogue and digital video transmission
EN 14373:2005 Explosion suppression systems
EN 50133-1 : 1996 AMD 1 2002 ALARM SYSTEMS - ACCESS CONTROL SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 1: SYSTEM REQUIREMENTS
EN 50131-10:2014 Alarm systems - Intrusion and hold-up systems - Part 10: Application specific requirements for Supervised Premises Transceiver (SPT)
EN 50131-2-8:2016 Alarm systems - Intrusion and hold-up systems - Part 2-8: Intrusion detectors - Shock detectors
OVE/ONORM EN 50131-2-3 : 2009 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-3: REQUIREMENTS FOR MICROWAVE DETECTORS
PREN 54-13 : DRAFT 2014 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 13: COMPATIBILITY AND CONNECTABILITY ASSESSMENT OF SYSTEM COMPONENTS
08/30180887 DC : DRAFT MAY 2008 BS EN 50131-4 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 4: WARNING DEVICES
PREN 54-5 : DRAFT 2011 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 5: HEAT DETECTORS - POINT DETECTORS
17/30353695 DC : 0 BS EN 50131-4 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 4: WARNING DEVICES
DD CLC/TS 50136-4:2004 Alarm systems. Alarm transmission systems and equipment Annunciation equipment used in alarm receiving centres
08/30195238 DC : 0
09/30196772 DC : 0 BS ISO 7240-24 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 24: SOUND-SYSTEM LOUDSPEAKERS
11/30236311 DC : 0 BS ISO 7240-10 - FIRE DETECTION AND ALARM SYSTEMS - PART 10: POINT-TYPE FLAME DETECTORS
99/703461 DC : DRAFT AUG 1999 BS EN 50131-2-2 - ALARM SYSTEMS - INTRUSION SYSTEMS - PART 2-2: REQUIREMENTS FOR PASSIVE INFRARED DETECTORS
I.S. EN 54-29:2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 29: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE AND HEAT SENSORS
I.S. EN 50134-5:2004 ALARM SYSTEMS - SOCIAL ALARM SYSTEMS - PART 5: INTERCONNECTIONS AND COMMUNICATIONS
S.R. CLC/TS 50661-1:2017 ALARM SYSTEMS - EXTERNAL PERIMETER SECURITY SYSTEMS - PART 1: SYSTEM REQUIREMENTS
17/30362102 DC : DRAFT AUG 2017 BS ISO 21927-4 - SMOKE AND HEAT CONTROL SYSTEMS - PART 4: NATURAL SMOKE AND HEAT EXHAUST VENTILATORS; DESIGN, REQUIREMENTS AND INSTALLATION
03/114763 DC : DRAFT SEP 2003 EN 54-18 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 18: REQUIREMENTS AND TEST METHODS FOR INPUT/OUTPUT DEVICES FOR USE ON THE TRANSMISSION PATHS OF FIRE DETECTION AND FIRE ALARM SYSTEMS
I.S. EN 50132-5-3:2012 ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 5-3: VIDEO TRANSMISSION - ANALOGUE AND DIGITAL VIDEO TRANSMISSION
NF EN 54-23 : 2010 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 23: FIRE ALARM DEVICES - VISUAL ALARM DEVICES
04/30104415 DC : DRAFT AUG 2004 EN 54-20 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 20: ASPIRATING SMOKE DETECTORS
02/708067 DC : DRAFT SEP 2002 BS EN 50131-2-4 - ALARM SYSTEMS - INTRUSION SYSTEMS - PART 2-4: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND MICROWAVE DETECTORS
DIN EN 54-26:2015-11 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 26: CARBON MONOXIDE DETECTORS - POINT DETECTORS
BS EN 50134-2:2017 Alarm systems. Social alarm systems Trigger devices
BS EN 50136-3:2013 Alarm systems. Alarm transmission systems and equipment Requirements for Receiving Centre Transceiver (RCT)
DIN EN 54-29:2015-06 Fire detection and fire alarm systems - Part 29: Multi-sensor fire detectors - Point detectors using a combination of smoke and heat sensors
BS EN 50131-2-4:2008 Alarm systems. Intrusion and hold-up systems Requirements for combined passive infrared and microwave detectors
PD CLC/TS 50131-11:2012 Alarm systems. Intrusion and hold-up systems Hold-up devices
DD CLC/TS 50131-2-4:2004 Alarm systems. Intrusion systems Requirements for combined passive infrared and microwave detectors
PD CEN/TR 16705:2014 Perimeter protection. Performance classification methodology
CEI EN 50131-2-6 : 2009 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-6: OPENING CONTACTS (MAGNETIC)
I.S. EN 54-26:2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 26: CARBON MONOXIDE DETECTORS - POINT DETECTORS
ISO 7240-11:2011 Fire detection and alarm systems Part 11: Manual call points
16/30299837 DC : 0 BS EN 50131-6 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 6: POWER SUPPLIES
16/30339543 DC : 0 BS EN 62820-3-2 ED 1.0 - BUILDING INTERCOM SYSTEMS - PART 3-2: APPLICATION GUIDELINES - ADVANCED SECURITY BUILDING INTERCOM
BS EN 50131-2-8:2016 Alarm systems. Intrusion and hold-up systems Intrusion detectors. Shock detectors
BS ISO 21927-9:2012 Smoke and heat control systems Specification for control equipment
ISO 7240-20:2010 Fire detection and alarm systems Part 20: Aspirating smoke detectors
EN 303 446-1 : 1.1.0 DRAFT ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR COMBINED AND/OR INTEGRATED RADIO AND NON-RADIO EQUIPMENT; PART 1: REQUIREMENTS FOR EQUIPMENT INTENDED TO BE USED IN RESIDENTIAL, COMMERCIAL AND LIGHT INDUSTRY LOCATIONS; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.1(B) OF DIRECTIVE 2014/53/EU
CLC/TS 50136-4:2004 Alarm systems - Alarm transmission systems and equipment - Part 4: Annunciation equipment used in alarm receiving centres
07/19986727 DC : 0 BS EN 50132-1 - ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 1: SYSTEM REQUIREMENTS
03/112283 DC : DRAFT AUG 2003 EN 1300 - SECURE STORAGE UNITS - CLASSIFICATION FOR HIGH SECURITY LOCKS ACCORDING TO THEIR RESISTANCE TO UNAUTHORIZED OPENING
PREN 50131-6 : DRAFT 2016 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 6: POWER SUPPLIES
UNE-EN 50136-2:2013 Alarm systems - Alarm transmission systems and equipment - Part 2: Requirements for Supervised Premises Transceiver (SPT)
BS EN 50131-3:2009 Alarm systems. Intrusion and hold-up systems Control and indicating equipment
03/102595 DC : 0 BS EN 14637 - BUILDING HARDWARE - ELECTRICALLY CONTROLLED HOLD-OPEN SYSTEMS FOR FIRE/SMOKE DOOR ASSEMBLIES - REQUIREMENTS, TEST METHODS, APPLICATION AND MAINTENANCE
07/30134620 DC : 0 BS EN 50131-6 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 6: POWER SUPPLIES
I.S. EN 54-28:2016 FIRE DETECTION AND FIRE ALARM SYSTEM - PART 28: NON-RESETTABLE LINE-TYPE HEAT DETECTORS
EN 50134-2:2017 Alarm systems - Social alarm systems - Part 2: Trigger devices
CEI EN 50131-1 : 2012 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
BS EN 50132-5:2001 Alarm systems. CCTV surveillance systems for use in security applications Video transmission
CEI EN 50134-5 : 2006 ALARM SYSTEMS - SOCIAL ALARM SYSTEMS - PART 5: INTERCONNECTIONS AND COMMUNICATIONS
PREN 54-28 : DRAFT 2015 FIRE DETECTION AND FIRE ALARM SYSTEM - PART 28: NON-RESETTABLE LINE-TYPE HEAT DETECTORS
UNE-EN 50131-10:2014 Alarm systems - Intrusion and hold-up systems - Part 10: Application specific requirements for Supervised Premises Transceiver (SPT)
I.S. EN 50136-3:2013 ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 3: REQUIREMENTS FOR RECEIVING CENTRE TRANSCEIVER (RCT)
ISO 7240-16:2007 Fire detection and alarm systems — Part 16: Sound system control and indicating equipment
I.S. EN 50131-2-4:2008 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-4: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND MICROWAVE DETECTORS
I.S. CLC TS 50131-3:2003 ALARM SYSTEMS - INTRUSION SYSTEMS - PART 3: CONTROL AND INDICATING EQUIPMENT
I.S. EN 50131-4:2009 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 4: WARNING DEVICES
I.S. EN 50131-2-8:2016 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-8: INTRUSION DETECTORS - SHOCK DETECTORS
I.S. EN 50131-8:2009 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 8: SECURITY FOG DEVICE/SYSTEMS
I.S. EN 50131-2-7-3:2012 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-3: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACTIVE)
ISO 7240-13:2005 Fire detection and alarm systems Part 13: Compatibility assessment of system components
BS EN 54-7:2001 Fire detection and fire alarm systems Smoke detectors. Point detectors using scattered light, transmitted light or ionization
CEI EN 50131-2-4 : 2008 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-4: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND MICROWAVE DETECTORS
I.S. EN 54-5:2017 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 5: HEAT DETECTORS - POINT HEAT DETECTORS
I.S. TS 50136-4:2004 ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 4: ANNUNCIATION EQUIPMENT USED IN ALARM RECEIVING CENTRES
13/30277397 DC : 0 BS EN 54-11 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 11: MANUAL CALL POINTS
DIN EN 54-7:2015-07 (Draft) FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
DIN EN 50134-2 : 2000 ALARM SYSTEMS - SOCIAL ALARM SYSTEMS - PART 2: TRIGGER DEVICES
PREN 54-2 : DRAFT 2016 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT
ISO 12239:2010 Smoke alarms using scattered light, transmitted light or ionization
CLC/TS 50131-2-7-1:2009 Alarm systems - Intrusion and hold-up systems - Part 2-7-1: Intrusion detectors - Glass break detectors (acoustic)
CEI CLC/TS 50136-7 : 2004 ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 7: APPLICATION GUIDELINES
BIS IS/ISO 7240-15 : 2004 FIRE DETECTION AND ALARM SYSTEMS - PART 15: POINT TYPE FIR E DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION SENSORS IN COMBINATION WITH A HEAT SENSOR
NF EN 50132-4-1 : 2002 ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 4-1: BLACK AND WHITE MONITORS
I.S. EN 50134-3:2012 ALARM SYSTEMS - SOCIAL ALARM SYSTEMS - PART 3: LOCAL UNIT AND CONTROLLER
S.R. CLC/TS 50131-2-7-2:2009 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-2: INTRUSION DETECTORS - GLASS BREAK DETECTORS (PASSIVE)
I.S. EN 50131-1:2006 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
UNE-EN 54-3:2016 Fire detection and fire alarm systems - Part 3: Fire alarm devices - Sounders
DIN EN 14604:2016-02 (Draft) Smoke alarm devices; German and English version prEN 14604:2016
EN 54-22:2015 Fire detection and fire alarm systems - Part 22: Resettable line-type heat detectors
EN 50131-2-4:2008 Alarm systems - Intrusion and hold-up systems - Part 2-4: Requirements for combined passive infrared and microwave detectors
DIN EN 54-10:2002-05 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 10: FLAME DETECTORS - POINT DETECTORS
DIN EN 54-3:2001-10 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 3: FIRE ALARM DEVICES - SOUNDERS
12/30256417 DC : 0 BS EN 54-31 - FIRE DETECTION AND FIRE ALARM SYSTEM - PART 31: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE, CARBON MONOXIDE AND OPTIONALLY HEAT SENSORS
09/30208451 DC : 0 BS EN 54-29 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 29: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE AND HEAT SENSORS
11/30201835 DC : 0 BS EN 50136-2 - ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 2: REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT)
07/30162539 DC : 0 BS EN 50131-2-2 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-2: INTRUSION DETECTORS - PASSIVE INFRARED DETECTORS
17/30350085 DC : DRAFT SEP 2017 BS EN 50131-8 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 8: SECURITY FOG DEVICES
ISO 7240-6:2011 Fire detection and alarm systems — Part 6: Carbon monoxide fire detectors using electro-chemical cells
I.S. EN 50131-2-6:2008 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-6: OPENING CONTACTS (MAGNETIC)
10/30218017 DC : 0 BS ISO 7240-11 - FIRE DETECTION AND ALARM SYSTEMS - PART 11: MANUAL CALL POINTS
BS EN 50131-10:2014 Alarm systems. Intrusion and hold-up systems Application specific requirements for Supervised Premises Transceiver (SPT)
BS EN 54-22:2015 Fire detection and fire alarm systems Resettable line-type heat detectors
09/30202602 DC : 0 BS EN 50134-3 - ALARM SYSTEMS - SOCIAL ALARM SYSTEMS - PART 3: LOCAL UNIT AND CONTROLLER
ISO 7240-10:2012 Fire detection and alarm systems — Part 10: Point-type flame detectors
13/30280588 DC : 0 BS ISO 7240-28 - FIRE DETECTION AND ALARM SYSTEMS - PART 28: FIRE PROTECTION CONTROL EQUIPMENT
03/117188 DC : DRAFT OCT 2003 BS EN 12101-10 - SMOKE AND HEAT CONTROL SYSTEMS - PART 10: POWER SUPPLIES
DD CLC/TS 50131-2-5:2004 Alarm systems. Intrusion systems Requirements for combined passive infrared and ultrasonic detectors
I.S. EN 50136-2:2013 ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 2: REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT)
12/30254899 DC : 0 BS EN 54-2 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT
DD CLC/TS 50131-2-7-2:2009 Alarm systems. Intrusion and hold-up systems Intrusion detectors. Glass break detectors (passive)
09/30195206 DC : 0 BS EN 54-30 - FIRE DETECTION AND ALARM SYSTEMS - PART 30: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF CARBON MONOXIDE AND HEAT SENSORS
CEI EN 50136-3 : 2014 ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 3: REQUIREMENTS FOR RECEIVING CENTRE TRANSCEIVER (RCT)
TR 103 056 : 1.1.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); SYSTEM REFERENCE DOCUMENT; SHORT RANGE DEVICES (SRD); TECHNICAL CHARACTERISTICS FOR SRD EQUIPMENT FOR SOCIAL ALARM AND ALARM APPLICATIONS
CEI EN 50132-5-3 : 2013 ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 5-3: VIDEO TRANSMISSION - ANALOGUE AND DIGITAL VIDEO TRANSMISSION
12/30254902 DC : DRAFT JAN 2012 BS EN 54-10 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 10: FLAME DETECTORS - POINT DETECTORS
PD CLC/TR 50531:2009 Alarm systems. Terms and definitions
09/30202799 DC : 0 BS EN 1300:2004/A1 - SECURE STORAGE UNITS - CLASSIFICATION FOR HIGH SECURITY LOCKS ACCORDING TO THEIR RESISTANCE TO UNAUTHORIZED OPENING
CEI EN 50131-2-7-1 : 2013 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-1: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACOUSTIC)
17/30358216 DC : DRAFT AUG 2017 BS EN 50131-2-10 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-10: INTRUSION DETECTORS - LOCK STATE CONTACTS (MAGNETIC)
BS EN 54-25:2008 Fire detection and fire alarm systems Components using radio links
CEI CLC/TS 50131-2-11 : 1ED 2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-11: INTRUSION DETECTORS - ALDDR
BS EN 50131-2-7-1 : 2012 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-1: INTRUSION DETECTORS - GLASS BREAK DETECTORS (PASSIVE)
11/30240406 DC : 0 BS ISO 7240-5 - FIRE DETECTION AND ALARM SYSTEMS - PART 5: POINT-TYPE HEAT DETECTORS
BS EN 54-30:2015 Fire detection and fire alarm systems Multi-sensor fire detectors. Point detectors using a combination of carbon monoxide and heat sensors
I.S. EN 50132-1:2010 ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 1: SYSTEM REQUIREMENTS
EN 54-5:2017 Fire detection and fire alarm systems - Part 5: Heat detectors - Point heat detectors
VDE 0830-4-2 : 2000 ALARM SYSTEMS - SOCIAL ALARM SYSTEMS - PART 2: TRIGGER DEVICES
EN 50134-5:2004 Alarm systems - Social alarm systems - Part 5: Interconnections and communications
S.R. CLC/TS 50131-2-9:2016 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-9: INTRUSION DETECTORS - ACTIVE INFRARED BEAM DETECTORS
S.R. CLC/TR 50531:2009 ALARM SYSTEMS - TERMS AND DEFINITIONS
I.S. EN 50131-3:2009 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 3: CONTROL AND INDICATING EQUIPMENT
S.R. CLC/TS 50131-2-11:2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-11: INTRUSION DETECTORS - ALDDR
CLC/TR 50531:2009 Alarm systems - Terms and definitions
I.S. EN 54-22:2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 22: RESETTABLE LINE-TYPE HEAT DETECTORS
I.S. EN 54-7:2000 COMPONENTS OF AUTOMATIC FIRE DETECTION SYSTEMS - POINT-TYPE SMOKE DETECTORS - DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
PREN 50131-8 : DRAFT 2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 8: SECURITY FOG DEVICES
EN 50131-2-2:2017 Alarm systems - Intrusion and hold-up systems - Part 2-2: Intrusion detectors - Passive infrared detectors
PREN 50131-1 : DRAFT 2004 ALARM SYSTEMS - INTRUSION SYSTEMS - PART 1: SYSTEM REQUIREMENTS
EN 54-13:2017 Fire detection and fire alarm systems - Part 13: Compatibility and connectability assessment of system components
UNI EN 54-16 : 2008 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 16: VOICE ALARM CONTROL AND INDICATING EQUIPMENT
EN 54-12:2015 Fire detection and fire alarm systems - Part 12: Smoke detectors - Line detectors using an optical beam
ISO 21927-10:2011 Smoke and heat control systems — Part 10: Specification for power output devices
ISO 7240-17:2009 Fire detection and fire alarm systems Part 17: Short-circuit isolators
S.R. CLC/TS 50131-2-10:2014 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-10: INTRUSION DETECTORS - LOCK STATE CONTACTS (MAGNETIC)
I.S. EN 54-13:2017 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 13: COMPATIBILITY AND CONNECTABILITY ASSESSMENT OF SYSTEM COMPONENTS
I.S. EN 50133-1:1997 ALARM SYSTEMS - ACCESS CONTROL SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 1 : SYSTEM REQUIREMENTS
BS EN 54-17:2005 Fire detection and fire alarm systems Short-circuit isolators
BS EN 54-21:2006 Fire detection and fire alarm systems Alarm transmission and fault warning routing equipment
UNI EN 54-3 : 2014 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 3: FIRE ALARM DEVICES - SOUNDERS
UNI EN 54-23 : 2010 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 23: FIRE ALARM DEVICES - VISUAL ALARM DEVICES
UNI EN 54-20 : 2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 20: ASPIRATING SMOKE DETECTORS
UNI EN 14604 : 2005 SMOKE ALARM DEVICES
EN 50132-1 : 2010 COR 2010 ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 1: SYSTEM REQUIREMENTS
UNE-EN 54-16:2010 Fire detection and fire alarm systems - Part 16: Voice alarm control and indicating equipment
11/30240441 DC : 0 BS EN 54-28 - FIRE DETECTION AND FIRE ALARM SYSTEM - PART 28: NON-RESET TABLE LINE TYPE HEAT DETECTORS
ISO 7240-12:2014 Fire detection and alarm systems Part 12: Line type smoke detectors using a transmitted optical beam
DIN EN 54-3:2014-09 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 3: FIRE ALARM DEVICES - SOUNDERS
11/30205538 DC : 0 BS EN 54-5 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 5: HEAT DETECTORS - POINT DETECTORS
BS EN 50131-2-3:2008 Alarm systems. Intrusion and hold-up systems Requirements for microwave detectors
04/30115467 DC : DRAFT JUN 2004 ISO 7240-13 - FIRE DETECTION AND ALARM SYSTEMS - PART 13: COMPATIBILITY ASSESSMENT OF SYSTEM COMPONENTS
CEI CLC/TS 50131-2-9 : 1ED 2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-9: INTRUSION DETECTORS - ACTIVE INFRARED BEAM DETECTORS
09/30170243 DC : 0 BS EN 54-12 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 12: SMOKE DETECTORS - LINE DETECTORS USING AN OPTICAL BEAM
DD CLC/TS 50131-4:2006 Alarm systems. Intrusion and hold-up systems Warning devices
ISO 7240-15:2014 Fire detection and alarm systems — Part 15: Point-type fire detectors using smoke and heat sensors
CEI EN 50131-2-7-2 : 2013 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-2: INTRUSION DETECTORS - GLASS BREAK DETECTORS (PASSIVE)
07/30158994 DC : 0 BS EN 54-22 - FIRE DETECTION AND FIRE ALARM SYSTEM - PART 22: LINE TYPE HEAT DETECTORS
EN 50136-3:2013 Alarm systems - Alarm transmission systems and equipment - Part 3: Requirements for Receiving Centre Transceiver (RCT)
11/30236274 DC : 0 BS ISO 7240-23 - FIRE DETECTION AND ALARM SYSTEMS - PART 23: VISUAL ALARM DEVICES
14/30290848 DC : 0 BS EN 54-13 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 13: COMPATIBILITY AND CONNECTABILITY ASSESSMENT OF SYSTEM COMPONENTS
DD CLC/TS 50131-2-7-1:2009 Alarm systems. Intrusion and hold-up systems Intrusion detectors. Glass break detectors (acoustic)
CLC/TS 50131-2-11:2017 Alarm systems - Intrusion and hold-up systems - Part 2-11: Intrusion detectors - ALDDR
BS EN 50131-2-6:2008 Alarm systems. Intrusion and hold-up systems Opening contacts (magnetic)
DD CLC/TS 50131-2-2:2004 Alarm systems. Intrusion systems Requirements for passive infrared detectors
DIN EN 54-22:2015-07 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 22: RESETTABLE LINE-TYPE HEAT DETECTORS
CEI CLC/TS 50131-2-8 : 2013 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-8: INTRUSION DETECTORS - SHOCK DETECTORS
99/715383 DC : DRAFT OCT 1999 BS EN 50131-4 - ALARM SYSTEMS - INTRUSION SYSTEMS - PART 4: WARNING DEVICES
BS ISO 7240-15:2014 Fire detection and alarm systems Point-type fire detectors using smoke and heat sensors
PD CLC/TS 50131-2-8:2012 Alarm systems. Intrusion and hold-up systems Intrusion detectors. Shock detectors
11/30245742 DC : 0 BS EN 50131-10 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 10: APPLICATION SPECIFIC REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT)
06/30117299 DC : 0 BS EN 54-15 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 15: POINT DETECTORS USING A COMBINATION OF DETECTED FIRE PHENOMENA
15/30290851 DC : 0 BS EN 54-25 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS
BS EN 54-27:2015 Fire detection and fire alarms systems Duct smoke detectors
CLC/TS 50131-2-7-2:2009 Alarm systems - Intrusion and hold-up systems - Part 2-7-2: Intrusion detectors - Glass break detectors (passive)
UNE-EN 50131-2-7-1:2013 Alarm systems - Intrusion and hold-up systems - Part 2-7-1: Intrusion detectors - Glass break detectors (acoustic)
EN 50131-6:2017 Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies
BS EN 50133-1:1997 Alarm systems. Access control systems for use in security applications System requirements
DD ENV 1300:1999 Secure storage units. Classification for high security locks according to their resistance to unauthorized opening
08/30162181 DC : DRAFT APR 2008 BS EN 54-26 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 26: POINT FIRE DETECTORS USING CARBON MONOXIDE SENSORS
CLC/TS 50131-2-8:2012 Alarm systems - Intrusion and hold-up systems - Part 2-8: Intrusion detectors - Shock detectors
UNI EN 54-25 : 2008 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS
I.S. EN 54-12:2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 12: SMOKE DETECTORS - LINE DETECTORS USING AN OPTICAL BEAM
UNE-EN 50131-2-8:2017 Alarm systems - Intrusion and hold-up systems - Part 2-8: Intrusion detectors - Shock detectors
S.R. CEN/TR 16705:2014 PERIMETER PROTECTION - PERFORMANCE CLASSIFICATION METHODOLOGY
CEI EN 50136-2 : 2014 ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 2: REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT)
S.R. CLC/TS 50131-11:2012 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 11: HOLD-UP DEVICES
ISO 7240-25:2010 Fire detection and fire alarm systems — Part 25: Components using radio transmission paths
I.S. CLC TS 50131-4:2006 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 4: WARNING DEVICES
PREN 54-29 : DRAFT 2009 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 29: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE AND HEAT SENSORS
PREN 54-4 : DRAFT 2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 4: POWER SUPPLY EQUIPMENT
I.S. EN 50131-2-7-3:2012/A2:2016 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-3: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACTIVE)
DIN EN 54-5:2001-03 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 5: HEAT DETECTORS - POINT HEAT DETECTORS
PREN 54-22 : DRAFT 2011 FIRE DETECTION AND FIRE ALARM SYSTEM - PART 22: RESETTABLE LINE TYPE HEAT DETECTORS
16/30312379 DC : 0 BS EN 54-2 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT
I.S. EN 54-3:2014 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 3: FIRE ALARM DEVICES - SOUNDERS
BIS IS/ISO 7240-11 : 2011 FIRE DETECTION AND ALARM SYSTEMS - PART 11: MANUAL CALL POINTS
15/30296472 DC : 0 BS EN 54-7 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
15/30290856 DC : 0 BS EN 54-4 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 4 : POWER SUPPLY EQUIPMENT
ISO 7240-3:2010 Fire detection and alarm systems Part 3: Audible alarm devices
I.S. EN 54-16:2008 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 16: VOICE ALARM CONTROL AND INDICATING EQUIPMENT
I.S. EN 50131-2-5:2008 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-5: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND ULTRASONIC DETECTORS
ISO 7240-28:2014 Fire detection and alarm systems Part 28: Fire protection control equipment
DIN EN 54-13:2014-09 (Draft) FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 13: COMPATIBILITY AND CONNECTABILITY ASSESSMENT OF SYSTEM COMPONENTS
I.S. EN 54-25:2008 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS
DIN EN 12101-10:2006-01 SMOKE AND HEAT CONTROL SYSTEMS - PART 10: POWER SUPPLIES
BS EN 54-12:2015 Fire detection and fire alarm systems Smoke detectors. Line detectors using an optical beam
BS EN 12101-10:2005 Smoke and heat control systems Power supplies
BS EN 54-23:2010 Fire detection and fire alarm systems Fire alarm devices. Visual alarm devices
BS EN 54-10:2002 Fire detection and fire alarm systems Flame detectors. Point detectors
EN 50134-3:2012/AC:2015 Alarm systems - Social alarm systems - Part 3: Local unit and controller
UNE-EN 50131-2-7-2:2013 Alarm systems - Intrusion and hold-up systems - Part 2-7-2: Intrusion detectors - Glass break detectors (passive)
BS EN 54-5 : 2017 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 5: HEAT DETECTORS - POINT HEAT DETECTORS
BS EN 54-2 : 1998 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT
DIN EN 54-12:2015-10 Fire detection and fire alarm systems - Part 12: Smoke detectors - Line detectors using an optical beam
09/30207398 DC : 0 BS ISO 7240-3 - FIRE DETECTION AND ALARM SYSTEMS - PART 3: AUDIBLE ALARM DEVICES
BS EN 54-11:2001 Fire detection and fire alarm systems Manual call points
BS EN 54-20:2006 Fire detection and fire alarm systems Aspirating smoke detectors
DIN EN 54-20:2009-02 Fire detection and fire alarm systems - Part 20: Aspirating smoke detectors (includes Amendment AC:2008)
DIN EN 54-18:2006-03 Fire detection and fire alarm systems - Part 18: Input/output devices
12/30248102 DC : 0 BS EN 14604 - SMOKE ALARM DEVICES
UNE-EN 50131-2-7-3:2013 Alarm systems - Intrusion and hold-up systems - Part 2-7-3: Intrusion detectors - Glass break detectors (active)
CLC/TS 50131-2-10:2014 Alarm systems - Intrusion and hold-up systems - Part 2-10: Intrusion detectors - Lock state contacts (magnetic)
EN 54-26:2015 Fire detection and fire alarm systems - Part 26: Carbon monoxide detectors - Point detectors
EN 54-29:2015 Fire detection and fire alarm systems - Part 29: Multi-sensor fire detectors - Point detectors using a combination of smoke and heat sensors
EN 54-21:2006 Fire detection and fire alarm systems - Part 21: Alarm transmission and fault warning routing equipment
EN 54-23:2010 Fire detection and fire alarm systems - Part 23: Fire alarm devices - Visual alarm devices
ENV 1300 : 1999 SECURE STORAGE UNITS - CLASSIFICATION FOR HIGH SECURITY LOCKS ACCORDING TO THEIR RESISTANCE TO UNAUTHORIZED OPENING
EN 54-28:2016 Fire detection and fire alarm system - Part 28: Non-resettable line-type heat detectors
EN 54-3:2014 Fire detection and fire alarm systems - Part 3: Fire alarm devices - Sounders
EN 54-16:2008 Fire detection and fire alarm systems - Part 16: Voice alarm control and indicating equipment
EN 54-27:2015 Fire detection and fire alarms systems - Part 27: Duct smoke detectors
EN 54-31:2014+A1:2016 Fire detection and fire alarm systems - Part 31: Multi-sensor fire detectors - Point detectors using a combination of smoke, carbon monoxide and optionally heat sensors
EN 54-30:2015 Fire detection and fire alarm systems - Part 30: Multi-sensor fire detectors - Point detectors using a combination of carbon monoxide and heat sensors
PREN 50131-2-2 : DRAFT 2016 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-2: INTRUSION DETECTORS - PASSIVE INFRARED DETECTORS
PREN 50131-10 : DRAFT 2011 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 10: APPLICATION SPECIFIC REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT)
DD CLC/TS 50131-2-7-3:2009 Alarm systems. Intrusion and hold-up systems Intrusion detectors. Glass break detectors (active)
DIN EN 54-23:2010-06 Fire detection and fire alarm systems - Part 23: Fire alarm devices - Visual alarm devices
DD CLC/TS 50131-2-6:2004 Alarm systems. Intrusion systems Requirements for opening contacts (magnetic)
I.S. EN 50131-2-3:2008 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-3: REQUIREMENTS FOR MICROWAVE DETECTORS
BS EN 50134-5:2004 Alarm systems. Social alarm systems Interconnections and communications
11/30205541 DC : 0 BS EN 54-7 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONISATION
BS ISO 7240-28:2014 Fire detection and alarm systems Fire protection control equipment
DIN EN 54-30:2015-11 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 30: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF CARBON MONOXIDE AND HEAT SENSORS
CEI EN 50131-2-7-3 : 2013 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-3: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACTIVE)
BS EN 54-29:2015 Fire detection and fire alarm systems Multi-sensor fire detectors. Point detectors using a combination of smoke and heat sensors
PREN 50132-5-3 : DRAFT 2010 ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 5-3: VIDEO TRANSMISSION - ANALOGUE AND DIGITAL VIDEO TRANSMISSION
10/30218198 DC : 0 BS EN 50132-5-3:2010 - ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 5-3: VIDEO TRANSMISSION - ANALOGUE AND DIGITAL VIDEO TRANSMISSION
CEI EN 50131-3 : 2009 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 3: CONTROL AND INDICATING EQUIPMENT
BS EN 50132-4-1:2001 Alarm systems. CCTV surveillance systems for use in security applications Black and white monitors
05/30127975 DC : DRAFT JAN 2005 ISO 7240-12 - FIRE DETECTION AND ALARM SYSTEMS - PART 12: LINE TYPE SMOKE DETECTORS USING A TRANSMITTING LIGHT BEAM
08/30188489 DC : DRAFT AUG 2008 BS EN 54-27 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 27: DUCT SMOKE DETECTORS
UNE-EN 50136-3:2014 Alarm systems - Alarm transmission systems and equipment - Part 3: Requirements for Receiving Centre Transceiver (RCT)
04/30105620 DC : DRAFT OCT 2004 EN 54-21 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 21: ALARM TRANSMISSION AND FAULT WARNING ROUTING EQUIPMENT
PREN 54-25 : DRAFT 2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS
CEI CLC/TS 50131-11 : 2013 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 11: HOLD-UP DEVICES
DIN EN 54-27:2015-05 Fire detection and fire alarm systems - Part 27: Duct smoke detectors
BS EN 54-26:2015 Fire detection and fire alarm systems Carbon monoxide detectors. Point detectors
CEI EN 50131-2-2 : 2008 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-2: INTRUSION DETECTORS - PASSIVE INFRARED DETECTORS
DD CLC/TS 50131-3:2003 Alarm systems. Intrusion systems Control and indicating equipment
BS EN 50136-2:2013 Alarm systems. Alarm transmission systems and equipment Requirements for Supervised Premises Transceiver (SPT)
I.S. EN 50131-2-7-2:2012 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-2: INTRUSION DETECTORS - GLASS BREAK DETECTORS (PASSIVE)
CEI EN 50131-2-5 : 2009 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-5: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND ULTRASONIC DETECTORS
CEI EN 50131-2-8 : 1ED 2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-8: INTRUSION DETECTORS - SHOCK DETECTORS
07/30162638 DC : 0 BS 50131-2-3 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-3: REQUIREMENTS FOR MICROWAVE DETECTORS
PD CLC/TS 50131-2-11:2017 PD CLC/TS 50131-2-11 Alarm systems - Intrusion and hold-up systems Part 2-11: Intrusion detectors - ALDDR
BS EN 50132-5-3:2012 Alarm systems. CCTV surveillance systems for use in security applications Video transmission. Analogue and digital video transmission
BS EN 50134-3:2012 Alarm systems. Social alarm systems Local unit and controller
CEI EN 50131-8 : 2010 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 8: SECURITY FOG DEVICE/SYSTEMS
07/30162640 DC : 0 BS EN 50131-2-4 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-4: REQUIREMENTS FOR COMBINED PASSIVE INFRA-RED AND MICROWAVE DETECTORS
UNE-EN 50131-4:2010 Alarm systems - Intrusion and hold-up systems - Part 4: Warning devices
07/30162643 DC : DRAFT AUG 2007 BS EN 50131-2-5 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-5: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND ULTRASONIC DETECTORS
04/30115471 DC : DRAFT JUL 2004 ISO 7240-21 - FIRE DETECTION AND ALARM SYSTEMS - PART 21: ROUTING EQUIPMENT
15/30291072 DC : 0 BS EN 54-28 - FIRE DETECTION AND FIRE ALARM SYSTEM - PART 28: NON-RESETTABLE LINE TYPE HEAT DETECTORS
EN 50131-1:2006/A2:2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
CLC/TS 50131-2-4:2004 Alarm systems - Intrusion systems - Part 2-4: Requirements for combined passive infrared and microwave detectors
S.R. CLC/TS 50131-2-7-1:2009 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-1: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACOUSTIC)
PREN 54-3 : DRAFT 2009 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 3: FIRE ALARM DEVICES - SOUNDERS
PREN 50131-4 : DRAFT 2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 4: WARNING DEVICES
UNE-EN 50131-1:2008 Alarm systems - Intrusion and hold-up systems -- Part 1: System requirements
TR 102 070-1 : 1.2.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); GUIDE TO THE APPLICATION OF HARMONIZED STANDARDS TO MULTI-RADIO AND COMBINED RADIO AND NON-RADIO EQUIPMENT; PART 1: ELECTROMAGNETIC COMPATIBILITY
BIS IS/ISO 7240-7 : 2011 FIRE DETECTION AND ALARM SYSTEMS - PART 7: POINT-TYPE SMOKE DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
NF EN 50132-1 : 2010 ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 1: SYSTEM REQUIREMENTS
S.R. CLC/TS 50136-7:2017 ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 7: APPLICATION GUIDELINES
I.S. EN 50134-2:2017 ALARM SYSTEMS - SOCIAL ALARM SYSTEMS - PART 2: TRIGGER DEVICES
ISO 7240-23:2013 Fire detection and alarm systems — Part 23: Visual alarm devices
I.S. EN 54-31:2014 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 31: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE, CARBON MONOXIDE AND OPTIONALLY HEAT SENSORS
CLC/TS 50131-2-2:2004 Alarm systems - Intrusion systems - Part 2-2: Requirements for passive infrared detectors
CLC/TS 50131-2-7-3:2009 Alarm systems - Intrusion and hold-up systems - Part 2-7-3: Intrusion detectors - Glass break detectors (active)
I.S. EN 54-27:2015 FIRE DETECTION AND FIRE ALARMS SYSTEMS - PART 27: DUCT SMOKE DETECTORS
S.R. CLC/TS 50131-2-8:2012 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-8: INTRUSION DETECTORS - SHOCK DETECTORS
ISO 21927-9:2012 Smoke and heat control systems — Part 9: Specification for control equipment
NF EN 50132-5 : 2002 ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 5: VIDEO TRANSMISSION
BS EN 50131-4:2009 Alarm systems. Intrusion and hold-up systems Warning devices
ONORM EN 54-7 : 2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
PREN 50136-2 : DRAFT 2011 ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 2: REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT)
CEI CLC/TS 50136-4 : 2004 ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 4: ANNUNCIATION EQUIPMENT USED IN ALARM RECEIVING CENTRES
DIN EN 54-25:2015-10 (Draft) FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS
CEI EN 50131-4 : 2010 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 4: WARNING DEVICES
ISO 7240-21:2005 Fire detection and alarm systems — Part 21: Routing equipment
BS EN 54-13:2017 Fire detection and fire alarm systems Compatibility and connectability assessment of system components
BS EN 54-4:1998 Fire detection and fire alarm systems Power supply equipment
BS EN 14604:2005 Smoke alarm devices
BS EN 54-3:2014 Fire detection and fire alarm systems Fire alarm devices. Sounders
EN 50132-5:2001 Alarm systems - CCTV surveillance systems for use in security applications - Part 5: Video transmission
EN 50131-3:2009 Alarm systems - Intrusion and hold-up systems - Part 3: Control and indicating equipment
DIN EN 14373:2006-01 Explosion suppression systems
CLC/TS 50131-11:2012 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 11: HOLD-UP DEVICES
DIN EN 54-21:2006-08 Fire detection and fire alarm systems - Part 21: Alarm transmission and fault warning routing equipment
DIN EN 54-28:2016-07 Fire detection and fire alarm system - Part 28: Non-resettable line-type heat detectors
I.S. EN 14373:2005 EXPLOSION SUPPRESSION SYSTEMS
EN 50136-2:2013 ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 2: REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT)
EN 50131-2-7-3:2012/A2:2016 Alarm systems - Intrusion and hold-up systems - Part 2-7-3: Intrusion detectors - Glass break detectors (active)
EN 50132-4-1 : 2001 ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 4-1: BLACK AND WHITE MONITORS
EN 50131-2-6:2008 Alarm systems - Intrusion and hold-up systems - Part 2-6: Opening contacts (magnetic)
EN 50131-2-7-2 : 2012 AMD 2 2016 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-2: INTRUSION DETECTORS - GLASS BREAK DETECTORS (PASSIVE)
EN 50131-2-3:2008 Alarm systems - Intrusion and hold-up systems - Part 2-3: Requirements for microwave detectors
DIN EN 54-16:2008-06 Fire detection and fire alarm systems - Part 16: Voice alarm control and indicating equipment
EN 50131-2-5:2008 Alarm systems - Intrusion and hold-up systems - Part 2-5: Requirements for combined passive infrared and ultrasonic detectors
EN 50131-2-7-1:2012/A2:2016 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-1: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACOUSTIC)
CLC/TS 50131-4:2006 Alarm systems - Intrusion and hold-up systems - Part 4: Warning devices
EN 50132-2-1 : 1997 ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - BLACK AND WHITE CAMERAS
EN 50131-4:2009 Alarm systems - Intrusion and hold-up systems - Part 4: Warning devices
NBR ISO 7240-13 : 2017 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 13: COMPATIBILITY ASSESSMENT OF SYSTEM COMPONENTS

IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 61000-4-11:2004/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
EN 61000-2-2:2002/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (IEC 61000-2-2:2002/A1:2017)
CLC/TS 50398:2009 Alarm systems - Combined and integrated alarm systems - General requirements
IEC 61000-4-20:2010 Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-2-2:2002+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
EN 61000-4-16:2016 Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz
EN 61000-4-20:2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-20: TESTING AND MEASUREMENT TECHNIQUES - EMISSION AND IMMUNITY TESTING IN TRANSVERSE ELECTROMAGNETIC (TEM) WAVEGUIDES

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.