EN 50123-5:2003
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Railway applications - Fixed installations - D.C. switchgear - Part 5: Surge arresters and low-voltage limiters for specific use in d.c. systems
01-01-2012
28-02-2003
Introduction
1 Common matters
1.1 Scope
1.2 Normative references
2 Non-linear resistor type gapped surge arresters
2.1 General
2.2 Definitions
2.3 Marking
2.4 Preferred ratings
2.5 Requirements
2.6 General testing procedure
2.7 Routine and acceptance tests
2.8 Type tests
3 Artificial pollution testing of surge arresters
4 Metal-oxide surge arresters without gaps
4.1 General
4.2 Definitions
4.3 Marking
4.4 Preferred ratings
4.5 Requirements
4.6 General testing procedure
4.7 Type tests
4.8 Routine and acceptance tests
5 Low-voltage limiters for specific use in d.c. systems
5.1 General
5.2 Definitions
5.3 Marking and classification
5.4 Preferred ratings
5.5 Requirements
5.6 Routine and acceptance tests
5.7 Type tests
Annex A (informative) Typical information given with
enquiries and tenders valid for all types
covered in this European Standard
Annex B (informative) High voltage filters for protection
against voltage surges
Figures
Tables
Applies, in particular, to surge arresters consisting of single or multiple spark gaps in series with one or more non-linear resistors. This consolidated version consists of the third edition (1991) and its amendment 1 (1999). Therefore, no need to order amendment in addition to this publication.
Committee |
CLC/TC 9X
|
DevelopmentNote |
To be read in conjunction with EN 50123-1, EN 60099-1 and EN 60099-4 (05/2003)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
UNE-EN 50123-5:2004 | Identical |
CEI EN 50123-5 : 2003 | Identical |
I.S. EN 50123-5:2003 | Identical |
SN EN 50123-5 : 2003 | Identical |
NF EN 50123-5 : 2004 | Identical |
NEN EN 50123-5 : 2003 | Identical |
PN EN 50123-5 : 2004 | Identical |
NBN EN 50123-5 : 2003 | Identical |
BS EN 50123-5:2003 | Identical |
DIN EN 50123-5 : 2003 | Identical |
96/209091 DC : DRAFT JUN 1996 | EN 50124-2 RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 2: OVERVOLTAGES AND RELATED PROPERTIES |
IEC 60255-21-2:1988 | Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section Two: Shock and bump tests |
IEC 60255-22-1:2007 | Measuring relays and protection equipment - Part 22-1: Electrical disturbance tests - 1 MHz burst immunity tests |
EN 60688:2013 | Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals |
EN 60255-23:1996 | Electrical relays - Part 23: Contact performance |
IEC 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
EN 50123-1:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 1: General |
IEC 60688:2012 | Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals |
IEC 60870-2-1:1995 | Telecontrol equipment and systems - Part 2: Operating conditions - Section 1: Power supply and electromagnetic compatibility |
EN 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
EN 61733-1:1996 | Measuring relays and protection equipment - Protection communication interfacing - Part 1: General |
EN 60099-1:1994/A1:1999 | SURGE ARRESTERS - PART 1: NON-LINEAR RESISTOR TYPE GAPPED SURGE ARRESTERS FOR A.C. SYSTEMS |
EN 60255-6 : 94 AC 95 | ELECTRICAL RELAYS - MEASURING RELAYS AND PROTECTION EQUIPMENT |
IEC 61733-1:1995 | Measuring relays and protection equipment - Protection communication interfacing - Part 1: General |
EN 50125-2:2002/corrigendum:2010 | RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 2: FIXED ELECTRICAL INSTALLATIONS |
IEC 61643-1:2005 | Low-voltage surge protective devices - Part 1: Surge protective devices connected to low-voltage power distribution systems - Requirements and tests |
IEC 60255-22-3:2007 | Measuring relays and protection equipment - Part 22-3: Electrical disturbance tests - Radiated electromagnetic field immunity |
IEC 60099-1:1991+AMD1:1999 CSV | Surge arresters - Part 1: Non-linear resistor type gapped surge arresters for a.c. systems |
IEC 60255-5:2000 | Electrical Relays - Part 5: Insulation coordination for measuring relays and protection equipment - Requirements and tests |
IEC 60255-6:1988 | Electrical relays - Part 6: Measuring relays and protection equipment |
IEC 60255-22-2:2008 | Measuring relays and protection equipment - Part 22-2: Electrical disturbance tests - Electrostatic discharge tests |
IEC 60255-21-1:1988 | Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section One: Vibration tests (sinusoidal) |
EN 60255-21-1:1995 | Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section 1: Vibration tests (sinusoidal) |
HD 546.2.1 : 200S1 | TELECONTROL EQUIPMENT & SYSTEMS - OPERATING CONDITIONS - ENVIRONMENTAL CONDITIONS & POWER SUPPLIES |
IEC 60255-23:1994 | Electrical relays - Part 23: Contact performance |
EN 60255-21-2:1995 | Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section 2: Shock and bump tests |
IEC 60255-22-4:2008 | Measuring relays and protection equipment - Part 22-4: Electrical disturbance tests - Electrical fast transient/burst immunity test |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.